0demerits
GREENWAY AT MALLARD CREEK
8230 GREENWAY VILLAGE DR, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060501052
Latest result0 demerits
Last inspectedApr 30, 2026
Inspections on record14
On record sinceApr 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 9, 2014Lower is betterApr 30, 2026
Inspections & violations
Apr 30, 2026 0 demerits · 0 violations
Inspector comments: Drain covers and pump verified via PDSC form. No violations observed during inspection. Flow meter operating properly. No night swimming permitted. Permit issued.
No violations were recorded for this inspection.
May 13, 2025 10 demerits · 2 violations
Inspector comments: EHS walked with COP James all restrictions met. Flow is operable and GPM doesn’t exceed 150, at 130. Permit was granted
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.Observed rope to buoy measuring at 59FT. CDI rope was cut and now measures at 50FT.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed ground doors without out audible alarm. CDI alarms were changed out and are working properly.
Jun 3, 2024 2 demerits · 1 violation
Inspector comments: Night swimming is not approved. Permit Restriction: Flowvis Must remain operable - not to exceed 150 GPM due to drain cover/filter restrictions.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. - CPO and EHS unable to verify if mirrors in restrooms are shatterproof.
Jul 12, 2023 14 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Ben Leonhardt.
Verified Ben’s CPO information. Verified items from previous inspection have been corrected.
Electrical permit E4445281 passed inspection 7-7-2023.
Originally arrived at 10:35 AM, observed Afras main drain covers installed. CPO located the A10RCFR covers and riser rings. Left and came back at 3:05 PM to verify approved Aquastar A10RCFR covers were installed and complete the inspection. 2ppm free chlorine and 7.3 pH for second visit.
NOTE - Main drain covers expire 10-1-2023. Will need to replace with ANSI/APSP/ICC-16 approved drain covers and submitted updated PDSC form to our office prior to cover expiration date.
Permit issued
No Night Swimming
Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed Afras main drain covers installed. Equalizer line covers abandoned per state guidelines. Does not match PDSC form. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Corrected. Operator reinstalled Aquastar A10RCFR covers and updated PDSC form.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One of 6 weirs broken. .2518(k) Provide functional weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder loose. .2521 Install ladders per manufacturer instructions. - Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet not working in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.
One stall in women’s restroom out of toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms.
Jun 15, 2023 26 demerits · 7 violations
Inspector comments: Pre-permit inspection conducted with James Rabon.
Like for like change of pool pump and motor. No record that electrical permit and inspection have been obtained from Mecklenburg County Code Enforcement. - G.S. 130A-2(3) Ensure all electrical work is completed by a licensed electrician and electrical permit and passing inspection are obtained from Code Enforcement. - Pre-permit item.
Pre-permit inspection did not pass
5, 6, 9, 16, 17, Electrical permit.
There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Have no CPO on file for this pool. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Pre-permit item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pool recently replastered. Looks like VGB2008 A10RCFRxxx covers installed without a riser ring. Covers expire 10-1-2023. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. - Pre-permit item.
Equalizer line covers appear to be plugged per state recommendations. Provide updated PDSC form. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
One section of depth markers and tiles covered with painters tape. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Corrected.
Some depth markers on pool wall are different than what is listed on pool deck. .2523(a) Provide depth markers on pool walls and pool deck to denote the water depth. - Pre-permit item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence < 48” in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Manga-latch < 54” high. .2528(a) Gate latches shall be 54" in height. - Pre-permit item.
Magnetic latch < 45” high, creating a foothold at main gate. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item.
Two windows from office to the pool deck capable of opening all the way. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Pre-permit item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in the deck where fill spout was. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash piping for one of the filters extends into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet not working in women’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.
Jun 2, 2022 6 demerits · 2 violations
Inspector comments: EHS verified GPM for flowvis flow meter after backwash.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed missing records for pool. Operator with start keeping records.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed handrail loose.
Apr 27, 2021 2 demerits · 1 violation
Inspector comments: No night swimming. Facility pool hours changed to 10am-dusk.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed far side ladder with missing covers.
Jun 12, 2020 0 demerits · 0 violations
Inspector comments: Inspection completed with Steven English on-site. No signature due to COVID-19.
No violations were recorded for this inspection.
Apr 3, 2019 8 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring 60 ft; CDI corrected during inspection (cut to 50 FT)
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed chemical storage directly on floor (Sodium Bi) of storage room; shelving is provided to provide for easy cleaning.
(NOTE) heavy wall damaged inside pump room in need of repair.
Apr 3, 2018 2 demerits · 1 violation
Inspector comments: Facility wants to close the pool at 9 PM; night swimming is not permitted until lighting can be verified.
The pump data plate could not be seen; the pump matches the picture in the approved VGB book. The motor is 5 HP. PDSC information verified.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. - Mirrors in the restroom are not shatterproof.
Apr 3, 2017 14 demerits · 6 violations
Inspector comments: 15. Recommend locating body hook in a more accessible location.
Correct pump information: Challenger Pentair 5HP, CFII-NI-5FE
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Missing 3 ladder bumpers
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump information does not match the Pool Drain compliance form
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required in equipment & chemical rooms
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Remark valves & pipes, labels faded and/ or missing
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror to be of shatterproof construction, shower is leaking
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Floors should be slip resistant
Mar 28, 2016 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemical room with one ceiling vent connected to HVAC. Provide continuous forced ventilation of natural cross ventilation.
Mar 31, 2015 10 demerits · 4 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating, bobber stuck, needs to be fixed to operate properly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical room has one ceiling vent connected to HVAC. Needs continuous forced ventilation or natural cross ventilation.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No shower signs posted. Need to post shower sign.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Clubhouse restrooms do not have shatterproof mirrors. GENERAL COMMENT: PDSC form must be received before permit can be issued.
Apr 9, 2014 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing end caps, needs replacing
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Areas of rock and other landscaping creating 46" fence height. Maintain 48" min. fence height.General Comment: Pool phone has been repaired from last visit but volume on phone is difficult to hear. Recommend replacing handset or any other solution to improve volume on phone.Main drain checks/ equalizer checks are being recorded daily.Permit issued.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GREENWAY AT MALLARD CREEK” or State ID 2060501052). Inspection type (routine vs. follow-up) is not published in the county's data.