6demerits
MCKENZIE PLACE
20315 COLONY POINT LN, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060501056
Latest result6 demerits
Last inspectedApr 28, 2026
Inspections on record14
On record sinceApr 23, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 23, 2014Lower is betterApr 28, 2026
Inspections & violations
Apr 28, 2026 6 demerits · 2 violations
Inspector comments: No Night Swimming
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Slight debris in pool, cleaning in progress.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder missing end cap
May 16, 2025 6 demerits · 1 violation
Inspector comments: No night swimming.
Permit restriction - flow meter must remain operable. Flow should remain between 73gpm to 98gpm.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm.
Observed low chlorine levels in pool - 0.6ppm. CDI: CPO increased chlorine level in pool (5.0ppm).
Apr 25, 2024 0 demerits · 0 violations
Inspector comments: NOTE:
- No violation observed at the time of operational permit inspection.
- CPO: Kara Gilchrist Present during the inspection.
No violations were recorded for this inspection.
Apr 21, 2023 18 demerits · 4 violations
Inspector comments: No night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed pool floor with debris. CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed floating debris in surface skimmers. CDI
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed ring buoy rope > 36’. CDI
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Observed deck chairs < 6’ from pool edge. CDI
May 10, 2022 0 demerits · 0 violations
Inspector comments: No violations noted. EHS confirmed PDSC information. Operator Kara Gilchrist on site during inspection. Permit issued.
No violations were recorded for this inspection.
Apr 14, 2021 8 demerits · 2 violations
Inspector comments: Kara Gilchrist present during this inspection.
NOTE: bottom of fence near the concrete at rear fence is a little lose but is still secure, Tighten this portion of the fence to the concrete.
Verified the pumps, main drains and equalizer covers.
Permit issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed both end caps on ladder cracked and chipped. Replace end caps.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 34ft. CDI - CPO corrected to 36ft which is what is required.
May 28, 2020 0 demerits · 0 violations
Inspector comments: Main gate was able to open and self close and self latch.
*No signature required due to COVID-19*
No violations were recorded for this inspection.
May 26, 2020 10 demerits · 2 violations
Inspector comments: 24. .2533(b) Provide sufficent lighting in pump room.
In pump room, observed one non working light. Light needs to be replaced.
*No signature required due to COVID-19*
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
According to pool information, rope is 36ft. Oberseved rope measuring 37 ft. Pool operator cut a foot off.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
Main gate could not open. There was a peice that broke off of the magnetic latch which did not allow a key to be entered to open the gate. Latch needs to be replaced.
Apr 25, 2019 10 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating plant material present in skimmer baskets. Baskets were cleaned by B. Vaughn. Suction verified to be present at the outlet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed junction box footholds outside of fencing. Construction date prior 2010.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed small amount of water present on the pump room floor. Chemicals observed to be properly stored as to prevent water contact.
Apr 3, 2018 14 demerits · 3 violations
Inspector comments: NO POINTS WERE TAKEN FOR THE FOLLOWING:
#8 - Observed on weir to be stuck. CDI to be floating properly.
PDSC information verified.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length to be 34.8 feet when 36 feet is required. CDI by switching rope out for rope measuring 36 feet.
**.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed junction box foot holds outside of fencing. Install mechanism so that there is no longer a foothold.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter to be moving freely but not showing the proper flow. Operator back washed during inspection and flow meter still will not go higher. Fix flow meter.
**.2518(g) Keep flow meter operational.
Apr 28, 2017 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 28, 2016 0 demerits · 0 violations
Inspector comments: Very nice job.
Permit pending due to corrected PDSC form
Update the form to reflect the Aquastar WAV12WR for the main drain covers.
No violations were recorded for this inspection.
Apr 27, 2015 12 demerits · 3 violations
Inspector comments: Current PDSC forms must be on file with MCHD prior to issuance of a permit.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed missing weir in surface skimmer. cdi
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
observed sections of pool fence < 48" in height.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
observed stuck flow meter. cdi
Apr 23, 2014 14 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope length too short - corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair the water leak in the pump room
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Clean the restrooms.