WINDSOR LANDING

1900 WINDSOR HILL DR, Matthews, NC 28105
Seasonal Swimming Pool · NC permit/State ID 2060501088
Latest result0 demerits
Last inspectedApr 10, 2026
Inspections on record14
On record sinceApr 9, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 Apr 9, 2014: 10Jul 27, 2015: 16Apr 4, 2016: 2Mar 28, 2017: 10Apr 12, 2018: 0Apr 3, 2019: 16Apr 22, 2020: 2Apr 5, 2021: 12Apr 13, 2021: 0Apr 14, 2022: 6Apr 3, 2023: 16Apr 5, 2024: 10Apr 2, 2025: 14Apr 10, 2026: 0
Apr 9, 2014Lower is betterApr 10, 2026

Inspections & violations

Apr 10, 2026 0 demerits · 0 violations
Inspector comments: Pool inspection showed no violations. Pool is approved for night swimming (Verification last completed 4/2/2025) Pool is okay to open at owner’s discretion. Permit sticker issued. No existing permit restrictions. Inspection conducted with CPO Mikey Gibson.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 2, 2025 14 demerits · 3 violations
Inspector comments: Inspection conducted with CPOs, Mikey Gibson and Kristy Shaw present. PDSC information verified onsite (new Aquastar MD covers installed per mfr instructions. No existing permit restrictions. All non-compliant items corrected onsite. EHS verified pool and perimeter lighting operable for night swimming to approve off previous approval. Permit issued. Pool permitted for night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one skimmer missing its weir. CDI - CPO installed new weir. -4-
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
REPEAT VIOLATION: .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring > 30 ft. CDI - Length cut to 30 ft by CPO during inspection. -6-
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed loose pavers under handrail. CDI - CPO secured pavers during inspection. -4-

View this inspection on the county portal ›

Apr 5, 2024 10 demerits · 2 violations
Inspector comments: Inspection conducted with CPO, Mikey Gibson present. PDSC information verified. No existing permit restrictions. All non-compliant items corrected onsite. Permit issued. Lights verified to be operable; swimming pool approved for night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring > 30 ft. CDI by CPO during inspection. -6-
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed loose paver under handrail. CDI by CPO during inspection. -4-

View this inspection on the county portal ›

Apr 3, 2023 16 demerits · 4 violations
Inspector comments: Pool approved for night swimming. No stickers in my pool packet. Will drop off sticker, can open without sticker.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed dry-rotted ring buoy rope. CDI-replaced
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed damaged coping. Correct any offsets >1/2” when they occur.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed this sentence not provided on the pool signs. CDI-paper sign in plastic sleeve provided until official sign is delivered
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F. Observed hot water in bathrooms <110F

View this inspection on the county portal ›

Apr 14, 2022 6 demerits · 2 violations
Inspector comments: General Comment: Observed pool lights not operable during inspection. Pool not permitted for night swimming. Operating hours adjusted from 10am until dusk. Contact inspector at 704-621-2294 to schedule night swimming permit visit if looking to get permitted for night swimming. Sufficient lighting must be present.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522 Provide required deck clearance. Observed pool furniture 4 ft. 5 in. From edge of pool deck. CDI, furniture relocated.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap provided.

View this inspection on the county portal ›

Apr 13, 2021 0 demerits · 0 violations
Inspector comments: New kinds 3 and phone was fixed

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 5, 2021 12 demerits · 3 violations
Inspector comments: Pool Phone Kings 3 did not allow me to call back. Busy and cut off
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
missing bumper on ladder
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck/bricks are loose and popping up. Fill in with some sand
#22 · Premises: emergency telephone provided −6
Kings 3 not working properly. It will not allow me to call back too the number. Busy

View this inspection on the county portal ›

Apr 22, 2020 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
no air gap in backwash.

View this inspection on the county portal ›

Apr 3, 2019 16 demerits · 5 violations
Inspector comments: Facility would like to have night swimming. EHS will schedule a night visit to verify visibility. Facility will close pool at dusk until EHS approves night swimming and amends permit.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. One skimmer with no weir. CDI - Replacement weir installed during the inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Depth marker tile missing. CDI- Approved depth marker tile installed during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Rubber bumpers missing on ladders. Replace.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter bobber is stuck. CDI - Maintenance repaired flow meter during the inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap at discharge pit.

View this inspection on the county portal ›

Apr 12, 2018 0 demerits · 0 violations
Inspector comments: No points deducted: Observed a few tiles that are loose near pool. Maintenance repairing during inspection. Made certain on no trip hazards.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 28, 2017 10 demerits · 2 violations
Inspector comments: Body hook was replaces during inspection and tiles was loose around pool
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
body hook was replaced during inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
tiles around deck were loose

View this inspection on the county portal ›

Apr 4, 2016 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2537(B)(10) - On or after May 1, 1993 all public swimming pools including those constructed prior to May 1, 1991 shall be maintained and operated in accordance with the following: (10) Diving equipment and pool slides including stairs and railing shall be maintained in good working order. Ladders are missing rubber stoppers at bottom. Rubber stoppers installed during the inspection.

View this inspection on the county portal ›

Jul 27, 2015 16 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Noted: Missing/broken tiles on pool wall. Repair proir to 2016 season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing (2) two weirs. Replace.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Missing bumppers on ladders. Replace to prevent continued damage to pool wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
rope not attached and in excess of required length. Corrected duing inspection.

View this inspection on the county portal ›

Apr 9, 2014 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing end caps on ladder.
#22 · Premises: emergency telephone provided −6
CDI - Observed the phone number on the sign was (704)847-4599 was different from 9-1-1 operator. Correct phone number (704)321-9449 was corrected on sign at phone.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed the pipes and valves were not labeled in the pump room. **Label all pipes and valves with direction of water flow.General Comments: #17 - Observed some decking bricks were loose.**Permit issued. Permit available at meckpools.charmeck.org in 3 business days.**Josh James was present during the inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WINDSOR LANDING” or State ID 2060501088). Inspection type (routine vs. follow-up) is not published in the county's data.