Inspections & violations

May 20, 2026 20 demerits · 5 violations
Inspector comments: NIGHT SWIMMING IS NOT PERMITTED. MAIN DRAINS EXPIRE: 5/23/2029 EQUALIZER COVERS EXPIRE: 5/23/2029
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. EHS observed small amount of debris on surface and on floor of pool. CDI - CPO vacuumed pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. EHS observed two skimmer baskets accumulating debris. CDI - CPO emptied skimmers.
#13 · Pool maintenance: contrasting band on steps and benches −4
.2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. EHS observed two missing tiles on leading edge of steps going into pool. Contrasting band is still clearly visible and missing tile does not create a trip hazard. CPO stated tiles will be replaced prior to opening. No permit action required.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. EHS observed letters on emergency pool signage faded and hard to read. CDI - CPO traced over lettering with sharpie to ensure sign is legible.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. EHS observed standing water in pump room. CPO stated they just conducted minor repairs on filter which caused water to leak out.

View this inspection on the county portal ›

May 1, 2025 18 demerits · 3 violations
Inspector comments: No night swimming.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.2. CDI - chlorine increased to 3.0 ppm
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 57ft. CDI - Rope was cut to 45 ft
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed pool phone number was incorrect. Phone number was corrected.

View this inspection on the county portal ›

Jun 20, 2024 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weirs in skimmer system in need of repair.

View this inspection on the county portal ›

Apr 18, 2023 26 demerits · 6 violations
Inspector comments: Pool does not plan to do night swimming. Pool will close at 8pm. Night swimming prohibited.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH levels at 7.0. CDI: corrected to 7.2 during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pollen, leaves, and other floating debris in pool. Cleaned during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 out of 6 weirs missing. Replaced. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed heavy pollen inside 2 out of the 6 skimmers and other floating debris inside rest of the skimmers. Cleaned during inspection
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing end cap/bumper on ladder at parking lot side. Replaced
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Throw rope attached to ring buoy greater than the required 45FT. Corrected to 45ft during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors not shatterproof.

View this inspection on the county portal ›

Apr 22, 2022 12 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
observed one ring buoy with a 10' rope, rope was discarded and 45' rope attached as required.
#22 · Premises: emergency telephone provided −6
emergency phone was not ringing back when called, new phone was installed and observed to be functioning correctly.

View this inspection on the county portal ›

Apr 15, 2021 12 demerits · 2 violations
Inspector comments: No night swimming permitted. Permit issued today.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Throw rope attached to ring buoy greater than the required 45FT. CPO Alex Clay corrected rope length during the inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone did not ring back when number for phone called today. CPO Alex Clay corrected during inspection by replacing the phone. Phone did connect to 911 operator.

View this inspection on the county portal ›

May 29, 2020 4 demerits · 1 violation
Inspector comments: Night swimming has not been approved. Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed damaged to the deck flooring around the right step ladder in the deep end. This was corrected and the deck was repaired with quick seal during the inspection.

View this inspection on the county portal ›

Apr 12, 2019 12 demerits · 3 violations
Inspector comments: Night swimming not permitted at this facility. Ensure permit remains posted so as to remain visible at all time.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris across bottom of pool and surface waters. CPO- advised all will be cleaned as weather permits asap.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Build up of pollen and debris in skimmers and baskets. Cleaning needed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Electrical outlets and post at various locations of the outside of the fence creating foot holds.

View this inspection on the county portal ›

Apr 18, 2018 6 demerits · 1 violation
Inspector comments: NIGHT SWIMMING IS NOT PERMITTED. LIFEGUARD IS NOT REQUIRED.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Vaccum covers were not securely fastened. CDI- Fastened. Keep securely fastened.

View this inspection on the county portal ›

Apr 20, 2017 6 demerits · 2 violations
Inspector comments: Please ensure that permit is posted and visible at pool area at all times. Allow up to 3 business days to access your permit at meckpools.charmeck.org
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris observed in pool. Maintain clean.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Debris in bathrooms. Maintain clean. Pool operator advised of intended cleaning.

View this inspection on the county portal ›

Apr 14, 2016 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed the ladder at the steps loose. CDI- tightened.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed the buoy rope too long. CDI- Cut to 45Ft.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed the pump room floor wet. Repair leak.NOTE: All Pump, MD, Skimmer, Etc information has been verified.*ACCESS POOL PERMIT ONLINE AFTER 3 BUSINESS DAYS AT HTTP://MECKPOOLS.CHARMECK.ORG*Report emailed to allieaquatech@gmail.com-(No chairs were out at the time of the inspection, ensure there is a minimum of 6ft between the pool edge and furniture when it is placed on the deck.)

View this inspection on the county portal ›

May 1, 2015 20 demerits · 5 violations
Inspector comments: This is not a pool permit. Pool permit will not be issued until an updated PDSC ( Pool Safety and Data Compliance form ) is submitted and approved by the Mecklenburg County Health Department. These forms can be found on the website at meckpools.charmeck.org
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed sand on bottom of pool near steps that operator stated was from pressure washed concrete from deck repairs. Observed debris accumulating on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets accumulating floating debris.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope loose and not tightly secured. CDI, operator tightened knot on throw rope to secure while on-site.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no hose bibs in restrooms.