‹ Back to search

6demerits

WATERLYN ASSOCIATION

14305 LAKE CROSSING DR, Charlotte, NC 28278
Seasonal Swimming Pool · NC permit/State ID 2060501117
Latest result6 demerits
Last inspectedApr 24, 2026
Inspections on record14
On record sinceJun 25, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Jun 25, 2014: 6Apr 24, 2015: 22Apr 21, 2016: 8Jun 20, 2017: 18May 24, 2018: 0Apr 15, 2019: 10May 8, 2020: 4Apr 28, 2021: 0Apr 12, 2022: 4May 9, 2023: 0May 2, 2024: 0Apr 17, 2025: 6May 20, 2025: 0Apr 24, 2026: 6
Jun 25, 2014Lower is betterApr 24, 2026

Inspections & violations

Apr 24, 2026 6 demerits · 1 violation
Inspector comments: Night swimming NOT permitted. Pressure gauge used for flow reduction. Gauges shall remain in place. Calculated TDH shall not be lower than 25 TDH less than 25 exceeds the maximum flow of the drain cover at 500 gpm. Suction Hazard.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope longer than 50 ft. CDI - CPO cut to the proper length.

View this inspection on the county portal ›

May 20, 2025 0 demerits · 0 violations
Inspector comments: GENERAL COMMENT: NO VIOLATIONS OBSERVED DURING INSPECTION. PRESSURE GAUGES VERIFIED ON SITE DURING INSPECTION AND MATCHING PDSC FORM NIGHT SWIMMING NOT PERMITTED PERMIT RESTRICTION: PRESSURE GAUGES MUST REMAIN IN PLACE ON PUMP. PRESSURE GAUGES SHALL MATCH PDSC FORM OR WITH CALCULATION DOES NOT EXCEED 500 GPM ON THE PUMP CURVE DUE TO DRAIN CLOVER SUCTION HAZARD. EHS SHALL CHECK PRESSURE GAUGES.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 17, 2025 6 demerits · 1 violation
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed main drain covers installed did not match PDSC form in field. Actual main drain covers are Aquastar 1216xxx

View this inspection on the county portal ›

May 2, 2024 0 demerits · 0 violations
Inspector comments: 17 psi, -4 mmHg on measured from gauges (flow meter not operable, see 2024 PDSC form). Loose nut on pump outlet flange tightened by CPO. Inspection conducted with Mike Sudol.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 9, 2023 0 demerits · 0 violations
Inspector comments: No violations.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 12, 2022 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer had significant floating debris, removed during inspection, verified skimmer was properly suctioning debris.

View this inspection on the county portal ›

Apr 28, 2021 0 demerits · 0 violations
Inspector comments: No violations noted

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 8, 2020 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets in need of cleaning.

View this inspection on the county portal ›

Apr 15, 2019 10 demerits · 2 violations
Inspector comments: Night swimming not permitted. Ensure permit remains visible at all times.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmer basket filled with debris. Maintain clean.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Rope on one buoy very brittle and allowing attachments to bouy to move around/ damaged. CDI- CPO AJ replaced bouy.

View this inspection on the county portal ›

May 24, 2018 0 demerits · 0 violations
Inspector comments: NIGHT SWIMMING IS NOT PERMITTED. NO LIFEGUARD REQUIRED NOT PRESENT.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 20, 2017 18 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
Chlorine concentration was recorded at 0.8ppm. CORRECTED- Chlorine added and concentration rose to 1 ppm after further test.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Facility PDSC forms states facility has 11 Waterway 640-80x Skimmer drain covers. Inspection revealed pool has 11 AQUASTAR 6HP. FACILITY MUST SUBMIT NEW PDSC PAPERWORK TO DEPARTNENT TO SHOW THIS. FACILITY HAS 3 DAYS TO DO SUCH, Observed 2 vaccum ports with no plugs in port. CORRECTED. Plugs were acquired and plugged in
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer basket missing weir. ITS NOT issued because majority of skimmers has weris.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap in backwash pipe. Provide air gap.

View this inspection on the county portal ›

Apr 21, 2016 8 demerits · 3 violations
Inspector comments: #25 Some pool chemicals being stored in equipment room. ** Store all chemicals in chemical room. POOL PERMIT CAN BE ISSUED.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some soil on pool wall tiles& debris on pool floor. ** Clean/ remove.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
All toilets & urinal are dirty. ** Clean all thoroughly.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow protection on hose bib in women's restroom or on hose bib on pool deck (by showers). ** Install vacuum breaker.

View this inspection on the county portal ›

Apr 24, 2015 22 demerits · 6 violations
Inspector comments: 13 - General Comment: Contrasting color band >1" from edge of step/bench. Maintain 1" or less between contrasting band (tiles) and edge. Given until 2016 to repair. Permit will not be issued next season unless repaired. Note: No back-up chlorinator on system. Salt system installed. Advise putting back-up chlorinator on system if operating below 60 F. VGB Paperwork incorrect. Aquastar 1216 on md and 6HPxxx on walls. Resubmit paperwork for approval. Permit will not be issued until PDSC form submitted and approved.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on pool floor. Keep clean. Pool equalizer line covers >1'2" from pool wall. Wall extended with pool putty. Corrected during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with debris. Keep clean.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck drains with >1/2" openings between. Corrected during inspection. Drains do not fit snug and protrude slightly. Any trip hazard blocked by pillars. Less than 1/2". Some damage to cement coping around pool. Keep in good repair.
#22 · Premises: emergency telephone provided −6
No dialing instructions at pool phone. Corrected during inspection.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
No labeling on pipes on recirculation system. Clearly identify with color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >114 F. Maintain at 110 F or below. Damaged countertop in restrooms. Keep in good repair. No paper towels in restrooms. Some toilets without toilet paper. Provide paper towels and toilet paper.

View this inspection on the county portal ›

Jun 25, 2014 6 demerits · 2 violations
Inspector comments: Pool permit not posted at pool today. Permit must be posted at the pool so that is visible. Permit may be obtained at meckpools.charmeck.org.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Three of nine weirs missing. Replace weirs.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Directional lines not labeled on equipment lines. Labeling is needed.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WATERLYN ASSOCIATION” or State ID 2060501117). Inspection type (routine vs. follow-up) is not published in the county's data.