‹ Back to search

14demerits

ARDREY COMMONS POOL

9716 WHITE FROST RD, Charlotte, NC 28277
Seasonal Swimming Pool · NC permit/State ID 2060501134
Latest result14 demerits
Last inspectedApr 17, 2026
Inspections on record13
On record sinceApr 17, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0714 Apr 17, 2014: 14Apr 15, 2015: 0Apr 19, 2016: 0Apr 11, 2017: 0Apr 4, 2018: 10Apr 8, 2019: 0Apr 15, 2020: 10Apr 27, 2021: 10Apr 13, 2022: 8Apr 14, 2023: 8Apr 9, 2024: 0Apr 25, 2025: 12Apr 17, 2026: 14
Apr 17, 2014Lower is betterApr 17, 2026

Inspections & violations

Apr 17, 2026 14 demerits · 3 violations
Inspector comments: Inspection completed with David This pool does not have night swimming
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.4. PIC dropped levels to 7.4 pH.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537b(3) Pool coping shall not be loose. Observed loose coping at ladder but not causing a trip hazard.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers filled with debris.

View this inspection on the county portal ›

Apr 25, 2025 12 demerits · 3 violations
Inspector comments: David Shultz present during inspection. No night swimming permitted
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Pool walls and floor stained in some areas.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Main entrance gate magnetic latch failed. CDI- David Shultz replaced latch while on site and was confirmed operational.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. No spare pump basket

View this inspection on the county portal ›

Apr 9, 2024 0 demerits · 0 violations
Inspector comments: No violations noted at time of inspection. Pool is okay to open at owners discretion. Permit and sticker provided.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 14, 2023 8 demerits · 2 violations
Inspector comments: Katherine
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Floating debris and sand on bottom of pool. Clean
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmer baskets. Keep baskets clean and free of debris.

View this inspection on the county portal ›

Apr 13, 2022 8 demerits · 2 violations
Inspector comments: Inspection completed with Katherine Fisher. No night swimming permitted at pool.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Floating debris and sand on bottom of pool. Clean
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmer baskets. Keep baskets clean and free of debris.

View this inspection on the county portal ›

Apr 27, 2021 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Install weirs securely. Observed one weir stuck to sides, not able to move up or down. PO will replace it with a new one.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed pool telephone number incorrect. HOA had changed phone companies but forgot to write correct number. Corrected during inspection from 704-541-3355 to 704-542-6459. Correct number written on signage.

View this inspection on the county portal ›

Apr 15, 2020 10 demerits · 2 violations
Inspector comments: No signature due to COVID-19.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 42 feet. CDI- rope was cut to 38 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate not self closing. CDI- gate corrected so it was self closing.

View this inspection on the county portal ›

Apr 8, 2019 0 demerits · 0 violations
Inspector comments: Observed a black flow prevention cover outside of the gate that could used as a foothold. Pool was constructed in 2007.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 4, 2018 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris accumulation inside skimmer baskets. Baskets were cleaned during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 40 feet. Rope was cut to 38 feet during inspection.

View this inspection on the county portal ›

Apr 11, 2017 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 19, 2016 0 demerits · 0 violations
Inspector comments: Updated PDSC form given at inspection. Permit issued once PDSC form is approved.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 15, 2015 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 17, 2014 14 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Leaf debris in skimmers
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope length measured 40'-9". Required length is 38'. Rope was shortened to 38'.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed fan not operating in pump room. Observed fan in chemical room could not be turned on.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.Observed no backflow prevention device on hose bib located under shower head.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ARDREY COMMONS POOL” or State ID 2060501134). Inspection type (routine vs. follow-up) is not published in the county's data.