0demerits
BEXLEY STEELECROFT
13900 STEELECROFT FARM LN, Charlotte, NC 28278
Seasonal Swimming Pool · NC permit/State ID 2060501149
Latest result0 demerits
Last inspectedApr 30, 2026
Inspections on record14
On record sinceJun 12, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 12, 2014Lower is betterApr 30, 2026
Inspections & violations
Apr 30, 2026 0 demerits · 0 violations
Inspector comments: Pool well maintained - no violations observed.
Reminder: Once pool is open for operation, ensure daily written records of water quality are maintained.
No violations were recorded for this inspection.
May 16, 2025 8 demerits · 2 violations
Inspector comments: Permit Restriction: Pool pump flow cannot exceed 258GPM for VGB main drain cover limitation.
A properly installed flow meter must remain in operation. Current flow meter is 10% accurate and approved for only the 2025 pool season. A 5% accurate flow meter must be installed in order to receive an operation permit next year.
All of the following were verified:
Main Drain Aquastar 9MFxxx 2008 (green dot)
Pump Hayward HCP3501
Piping all 3” at pump room floor, skimmer, main drain and return
Flow meter does not exceed 258gpm
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed blank records logs. Per CPO, records were not being recorded because pool had not been opened. Ensure to record records as they are taken, even if pool is not yet opened.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket. Per CPO, pump basket is on order.
**OKAY TO ISSUE PERMIT PER CHRIS S.**
Apr 23, 2024 4 demerits · 1 violation
Inspector comments: Night swimming not permitted.
90 GPM
Pool will be open from dawn til dusk.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets at time of inspection.
May 8, 2023 8 demerits · 3 violations
Inspector comments: No Night Swimming Permitted
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed damage to walls in the pump and chemical room
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
door from lobby to pool did not have audible alarm present. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing endcap on one pool ladder, replaced during inspection.
Jun 16, 2022 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. CDI: pH is now 7.2
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing face plate of handrail.
Apr 1, 2021 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladder missing end caps.
May 6, 2020 6 demerits · 1 violation
Inspector comments: Phone operation was confirmed during visit. Phone needed three tries to reach 911, operates by auto dialing. Able to reach 911 within 30 seconds of pick up. Operator stated that a work order has already been placed to repair phone, as well that there are phones located in the apartment lobby which is open during pool operation.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed pool buoy rope tangled during inspection. Untangled by EHS
Jun 6, 2019 0 demerits · 0 violations
Inspector comments: Onsite visit with Chris York.
Pool closed for chemicals.
Ring buoy damaged and in need of being replaced.
Call Chris Sells when chlorine is corrected and ring buoy is replaced at 704 576 8678.
Observed 8HPxxx equalizers installed without backer plate.
phone call to Steve Barnes to determine installation is approved, not in left voice mail.
No violations were recorded for this inspection.
Apr 11, 2019 12 demerits · 3 violations
Inspector comments: 8) .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. CPO removed debris in skimmer baskets during the inspection.
PDSC form was reviewed.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. CPO corrected during the inspection and pH was at 7.2.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed 2 ladders missing the ladder bumpers. Ensure to replace.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket. Ensure to provide a spare basket.
Apr 26, 2018 18 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed only pH, chlorine, and main drains checked for the month. Ensure to check the Total Alkalinity & Cyanuric Acid weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the baskets. Clean.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed the ring buoy and the body hook hanging behind bushes. Inspector could not reach it and it was difficult for Mr. Jovany to reach. CDI- Relocated to a visible and accessible place.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed the gate by the pump room not self closing/self latching. CDI- Tightened- Closing now.
Per Jovany, no night swimming.
Permit provided #18-600639 (county); 2060501149 (state)
Report emailed to jrivera@weinsteinproperties.com
Apr 12, 2017 0 demerits · 0 violations
Inspector comments: Ventilation grates on ceiling in chemical room dusty and in need of cleaning.
Some weir baskets with debris. Maintain weir baskets and keep clean.
No violations were recorded for this inspection.
Mar 24, 2016 6 demerits · 2 violations
Inspector comments: #6 Main drains, equalizer covers and pump was validated
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Ensure that facility provides extra hair lent basket for pump.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors in restroom must be constructed of shatterproff materials.
Apr 8, 2015 0 demerits · 0 violations
No violations were recorded for this inspection.
Jun 12, 2014 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on floor of equipment room directly under and at pump and lines. Keep floor dry.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BEXLEY STEELECROFT” or State ID 2060501149). Inspection type (routine vs. follow-up) is not published in the county's data.