SUMMERS WALK
17240 SUMMERS WALK BLVD, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060501153
Latest result20 demerits
Last inspectedApr 14, 2026
Inspections on record14
On record sinceJun 4, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 4, 2014Lower is betterApr 14, 2026
Inspections & violations
Apr 14, 2026 20 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor with debris
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy longer than 50 ft. Rope cut to 50 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed gate not self closing/ latching. CDI- Gate fixed to self close/ latch.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed pool without pool signage for Warning- no lifeguard on duty. CDI- CPO Called and fixed gate during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed no shatterproof mirrors in restrooms.
Apr 8, 2025 10 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Maintain pool floors clean and free of debris; Observed pool flooring in need of cleaning on the left side of pool near pump room.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Provide throw rope at proper length; Observed throw rope measuring 60ft, CDI rope cut to 50ft (required) during inspection.
May 10, 2024 0 demerits · 0 violations
Inspector comments: The pump does match the PDSC forms. Walked with John Rhodes. PDSC form states Pentair model # EQK1000 10HP .
No violations were recorded for this inspection.
Apr 26, 2024 12 demerits · 3 violations
Inspector comments: Permit denied due to pump change out without infield plan review or new PDSC
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer, CDI cleaned during inspection
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Observed new pump in pump room. MCPH shows Pentair model #CH100 actual pump Pentair model# EQK1000
Apr 20, 2023 4 demerits · 1 violation
Inspector comments: doors from club house must remain locked at all times also self latch and close
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
small amount of scum on tile @ water line. Small amount of leaf debris keep pool free of debris
Apr 20, 2022 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 7, 2021 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed some leaf debris on bottom.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed no opeational ventilation.
May 7, 2020 6 demerits · 1 violation
Inspector comments: Taylor Mastin present during inspection.
No signature due to COVID19 social distancing requirements.
#22 · Premises: emergency telephone provided −6
Observed emergency phone with incorrect number.
Corrected during inspection.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Apr 5, 2019 10 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed no alarm on clubhouse doors entering the pool area. These doors shall remained locked while pool is in use. All bathers enter through the main gate.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed signs without correct verbage. Signs posted said Children under the age of 13 are not permitted in the pool area without adult supervision. Correct sign posted during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed fan activated in chemical when the light switch is turned on.
May 9, 2018 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed debris in the skimmers. Cleaned out skimmers during inspection. Advised to keep skimmers free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
observed loose handrail. Tightened handrail during inspectin. Advised to keep handrails tight.
May 18, 2017 8 demerits · 3 violations
Inspector comments: PDSC form states that the pool has 10 EQ lines. Pool actually has 12 EQ lines. EHS advsied pool operator to resubmit an accurate PDSC form. Permit is not issued until form is approved and pool shall remain closed until the permit is issud.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in surface skimmers. Keep clean.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrail.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on floor in pump room. Bags of calcium on the floor.
Jul 5, 2016 22 demerits · 7 violations
Inspector comments: ITS issued for #8, #18.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record total alkalinity & cyanuric acid 1 x week
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Numerous weirs missing
#18 · Premises: lifeguards present or warning signs posted −4
Incorrect wording on Pool rules sign
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on the hose bib with the hose attached to it
May 12, 2015 4 demerits · 1 violation
Inspector comments: Pool permit inspection passed. Pool is not approved to open until permit is available online.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed 4 missing tiles on side of pool. Repair prior to opening pool.
Jun 4, 2014 16 demerits · 3 violations
Inspector comments: .Observed club house doors to be non self-latching/closing & no audible alarm. CPO states that doors remain locked at all times.
#3 · Water quality: pool water pH −6
pH of pool shall be between 7.2 and 7.8. Observed pH at 7.1. CDI-pH raised to 7.2
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record books shall record adjustments and closures. Observed chlorine recorded at 0ppm on record books with no adjustments or closures. CPO stated that lifeguard records information daily and may have been confused. Will return in a week to ensure correct record keeping.
#22 · Premises: emergency telephone provided −6
911 must have the correct location information and phone number for the pool. Observed two signs with incorrect phone number. CDI-correct number posted.