12demerits
SOUTH OAK CROSSING APARTMENTS
7609 KING RIDGE DR, Charlotte, NC 28217
Seasonal Swimming Pool · NC permit/State ID 2060501157
Latest result12 demerits
Last inspectedJun 27, 2025
Inspections on record13
On record sinceJun 12, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 12, 2014Lower is betterJun 27, 2025
Inspections & violations
Jun 27, 2025 12 demerits · 2 violations
Inspector comments: Permit Restriction:
Flow meter must remain operable. Flow required between 65 gpm and 98 gpm to meet turnover and flow restriction of the filter. Flow greater than 150 gpm exceeds the main drains. Suction Hazard.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
Observed vacuum line with no plug at start of inspection. Observed gpm listed within permit restrictions (65 gpm to 98 gpm) not met at start of inspection. CDI - CPO acquired properly fitting vacuum line plug and screwed into fitting prior to end of inspection. CPO adjusted RPM on motor; gpm as read on flow meter was observed at approximately 70 gpm prior to end of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached.
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed ring buoy rope at 26’ at start of inspection (permit requires 27’ rope.) Observed telescoping body hook pole with push button tabs for hook. CDI - CPO made body hook pole non collapsible via screws and bolts placed through telescoping portion of pole. Hook was solidly attached to pole via screw and bolt. Ring buoy rope was unknotted by CPO such that length of 27’ was achieved.
Apr 25, 2024 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 18, 2024 16 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH level. PH level measured 7.0.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Fill line inside the pool did not have a cover. Install a cover over fill line in pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Body hook and pole was not available.
Apr 26, 2023 0 demerits · 0 violations
Inspector comments: No violations were observed during the inspection.
No violations were recorded for this inspection.
Jul 13, 2022 0 demerits · 0 violations
Inspector comments: All items corrected. No violations.
No violations were recorded for this inspection.
Jun 30, 2021 0 demerits · 0 violations
Inspector comments: POOL PASSED INSPECTION
No violations were recorded for this inspection.
Jul 15, 2020 4 demerits · 1 violation
Inspector comments: No points were taken for the following:
22. Observed the 911 dispatcher having a lot trouble hearing me on the phone while verifying the address and phone number. Phone may needs to be checked out to ensure dispatcher can hear callers more clearly.
**.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmer baskets. Cleaned during the inspection.
**.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Apr 24, 2019 6 demerits · 1 violation
Inspector comments: EMERGENCY PHONE VOLUME VERY LOW. WAS ABLE TO COMMUNICATE WITH 9-1-1 DISPATCH BUT VOLUME MADE HEARING SLIGHTLY DIFFICULT. ADVISE FACILITY TO FIX/ADJUST VOLUME.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacum cap was not covered. CDI- COVERED.
May 3, 2018 10 demerits · 3 violations
Inspector comments: .2530(a) Emergency phone shall remain operable. 911 operator indicated today that volume on the phone was very low, and there was difficulty hearing inspector on the other end. CPO was advised that phone is operating, but ensure that volume is corrected.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Door leading from restroom hallway does have a self closing device and audible alarm. However, alarm was not working correctly today. CPO began working on it during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Weir missing from skimmer. CPO replaced.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Correct signage missing. CPO advised that correct signage had been ordered and called during inspection as to delivery of sign. CPO Oscar advised that sign was to be delivered today. CDI- Office personnel printed out temporary missing verbiage in correct size lettering, posted on the interior windows facing out to pool deck main area. Ensure that new sign has exact lettering and phasing prior to posting.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(m) Keep restrooms and fixtures clean and in good repair. Repair papertowel dispenser and provide papertowels in the restrooms.
May 19, 2017 8 demerits · 2 violations
Inspector comments: Observed some signage fading on pool sign. Operator not able to get pool lights working. Operator stated that there was no night swimming.
This is not a pool permit. Pool permit will be available on MCHD website at meckpools.charmeck.org within 2 to 3 business days.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Doors entering into office area should remain locked due to not having self closure device. (Corrected by locking doors).
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Operator was able to get flow meter working properly while on-site.
Jun 7, 2016 8 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ensure that ladders/handrails are tight and secure. Check frequently.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Doors entering into office area should remain locked due to not having self closure device. (Corrected by locking doors).
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Need to post shower before entering pool sign.
Jul 15, 2015 14 demerits · 3 violations
Inspector comments: POST THE POOL PERMIT IN PUBLIC VIEW FROM THE POOL DECK.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed gaps in the daily checks where records are not being kept. pH, Cl2, and main drains must be checked every day the pool is open. Alkalinity and cyanuric acid must be checked once a week.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy to be damaged. Observed throw rope to be 26ft. long. It was corrected to 27ft. and a new ring buoy was obtained.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observe|d flow meter to be stuck. Repair it.
Jun 12, 2014 26 demerits · 7 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one weir missing. Needs replacing.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrail. Needs tightening.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed buoy rope too long. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed office doors need self-closures. Need to self-close and self-latch. ITS issued.
#18 · Premises: lifeguards present or warning signs posted −4
Observed wrong signs posted. "WARNING" is not at least 4 inches tall. Get correct signage. ITS issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not working. Replace or repair
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in bathrooms are not shatterproof.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SOUTH OAK CROSSING APARTMENTS” or State ID 2060501157). Inspection type (routine vs. follow-up) is not published in the county's data.