‹ Back to search

8demerits

VILLAGES AT BACK CREEK

9808 HANBERRY BLVD, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060501162
Latest result8 demerits
Last inspectedApr 24, 2026
Inspections on record11
On record sinceApr 24, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 Apr 24, 2014: 6Jun 22, 2015: 8May 6, 2016: 4Aug 23, 2018: 14Jun 7, 2019: 8May 27, 2020: 2Jul 16, 2021: 10Jun 2, 2022: 0Jul 19, 2024: 20Apr 30, 2025: 0Apr 24, 2026: 8
Apr 24, 2014Lower is betterApr 24, 2026

Inspections & violations

Apr 24, 2026 8 demerits · 3 violations
Inspector comments: PERMIT RESTRICTION: VFD required to be set at 60hz (full speed) for pump approval; pump approved on design flow. NEW FENCE INSTALLED APPROVED 8/23/18. GATE PRE-5/2010 Construction: Rope: 50’ NIGHT SWIMMING NOT PERMITTED.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Rung extending past 6”. CPO worked on ladder during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence with opening greater than 4” on side facing mailboxes. CPO adjusted fence to less than 4” gap during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. handsink with low pressure. CPO to contact supervisor for maintenance.

View this inspection on the county portal ›

Apr 30, 2025 0 demerits · 0 violations
Inspector comments: Permit restrictions: Night swimming not permitted VFD required to be set at 60hz (full speed) for pump. Pump is approved on design flow.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 19, 2024 20 demerits · 6 violations
Inspector comments: Observed the following items for infield plan review verification Pump - Hayward HCP30703 Main Drains - Aquastar 12MFxxx Returns - 16 Skimmers - 8 Filters - 2xTR140C Infield plan review complete Permit restriction: VFD must remain at 60hz. Pump is approved on design flow.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed several skimmer weirs stuck. .2518(k) Surface skimmers shall be installed per manufacturer's instructions.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder in shallow end >6" from wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed several chips on deck in need of repair. .2537(2) Decks shall be kept in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pressure gauge not reading correctly on filter. Corrected during inspection. .2519(k) Provide operational pressure gauge on filter.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed urinal not functioning in restroom. .2526(f) At least one sink, one toilet, one urinal is required for men's restroom.

View this inspection on the county portal ›

Jun 2, 2022 0 demerits · 0 violations
Inspector comments: 2 flow metered 120(2) =240

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 16, 2021 10 demerits · 3 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.OLD FORMS PRESENT with no MD check. CDI- written in
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.observed some leaf debris on pool floor
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed none

View this inspection on the county portal ›

May 27, 2020 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Observed ladders missing rubber bumpers. Benji was present during the inspection.

View this inspection on the county portal ›

Jun 7, 2019 8 demerits · 2 violations
Inspector comments: Chaas Delgado present during inspection. No night swimming permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 3 of 8 weirs missing. all 3 replaced during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed 1 of 2 gates not self-closing or self-latching as landscaping was in the way. CPO adjusted plants and was able to get the gate to self-close and self-latch during inspection.

View this inspection on the county portal ›

Aug 23, 2018 14 demerits · 4 violations
Inspector comments: Received updated PDSC. PDSC approved. Infield plan review of fence is complete. Permit issued
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed on ladder not seated well. Keep ladders in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy rope legenth at 65 feet. Corrected to 50 during inspection. Provide ring buoy with proper rope legenth.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gaps under fence greater than 2 inches. Corrected during inspection. Maintin 2" or less between grade and bottom of fence
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Observed debris on mens restroom floor. Keep floors clean

View this inspection on the county portal ›

May 6, 2016 4 demerits · 1 violation
Inspector comments: Observed some cracked areas on the deck. Patch the deck. Failure to do so may result in permit action at a later time. PERMIT WILL BE ISSUED WHEN UPDATED PDSC FORM SHOWING NEW EQ COVER INSTALL DATES IS APPROVED
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence to have gaps under some sections greater than 4" wide. Pool was built prior to 2010.

View this inspection on the county portal ›

Jun 22, 2015 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed missing daily records for Sundays. **Chlorine value, pH values and main drain check must be performed and recorded daily. Documentation for pool closure must also be maintained.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor plaster was wheather and stained, and the pool deck edge with a major crack at the 5ft end of the pool.

View this inspection on the county portal ›

Apr 24, 2014 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed turtle style cover missing inside skimmers. Replace missing throttle/turtle device.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing end caps at ladders. Replace missing end cap.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “VILLAGES AT BACK CREEK” or State ID 2060501162). Inspection type (routine vs. follow-up) is not published in the county's data.