6demerits
PARK SOUTH STATION
6600 CENTRAL PACIFIC AVE, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060501166
Latest result6 demerits
Last inspectedApr 29, 2026
Inspections on record15
On record sinceApr 24, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 24, 2014Lower is betterApr 29, 2026
Inspections & violations
Apr 29, 2026 6 demerits · 2 violations
Inspector comments: Observed drain covers appear to be 2008 with teal dots in center. PIC stated drain covers appeared to be 2008. PDSC form states covers approved were 2017. Per H. McIntosh, due to uncertainty of color of dot, approval of permit with these observed installed covers is approved.
Night Swimming not permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed some dirt on pool floor.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.Observed circular covers not affixed to bottom of hand rails.
Apr 23, 2026 4 demerits · 1 violation
Inspector comments: Facility failed due to lack of grounding wire. No chemicals were checked. Pool is placed on Q status.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Facility PDSC states Pentair EQ750, verified on site. Pump was observed with no grounding wire. Facility fails. Required electrician to properly attach grounding wire. Will need receipt for proof to redo pool inspection.
Apr 21, 2025 16 demerits · 4 violations
Inspector comments: Inspection with CPO, Brandon Vaughn.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy at 54 ft in length. CDI-PIC shorted rope to 50 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed magnetic lock gate towards park that could not self latch and power for magnetic lock was off. CDI-CPO drilled brackets in to permanently close gate and is no longer accessible. Gate does not have a walk way and is in the middle of a grass field towards a park.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed small crack in concrete on pool deck near pool steps closest to clubhouse.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed water that was turned off in women’s restroom. CDI-CPO turned water on.
Apr 17, 2024 10 demerits · 3 violations
Inspector comments: ***Unable to determine if pump is grounded. EHS recommends having a certified electrician examine it for safety.
All clubhouse doors are self closing, self latching. Windows do not open.
Interlock tested and working properly.
Inspection completed with CPO, Joe Brennan
All permit compliance items corrected during inspection
CPO log records begin today
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Pool requires a 50ft long buoy rope. Rope was 55ft. CPO cut down to 50ft during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Pump room light and chemical room light are not operating.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F. Bathroom hand sink water is 118 degrees.
Apr 21, 2023 0 demerits · 0 violations
Inspector comments: Night swimming not permitted
No violations were recorded for this inspection.
Apr 21, 2023 0 demerits · 0 violations
Inspector comments: Gate did not latch via magnetic latch. EHS was able to pull gate open without a fob.
Permit denied. Status changed to Q.
No violations were recorded for this inspection.
Apr 20, 2022 8 demerits · 2 violations
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed emergency phone location not listed on rear pool sign. CDI PIC labeled location of emergency phone.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in pool restrooms not shatterproof.
Apr 13, 2021 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed deep holes on pool deck where ladder would normally fit. PO provided and installed ladder during inspection.
Jun 4, 2020 2 demerits · 1 violation
Inspector comments: Inspection was conducted with Jude Powell. Ensure PH does not exceed passed 7.8 Observed PH at maximum allowable limit during inspection.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2526(c) Restroom floor shall be sloped to drain. Remove stand still water from near hand sink. Ensure hand sink soap dispensers are properly dispensing.
Apr 15, 2019 22 demerits · 6 violations
Inspector comments: No night swimming visit required. Pool operating hours are from 8a - 8p. Night swimming is not permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaves and debris on pool floor. CDI: pool being cleaned during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. CDI: cleaned during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for both ring buoys > 50ft. CDI: corrected to 50ft during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed side locked gate not self-closing. CDI: repaired and self-closing during inspection. Gate will stay permanently locked.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on pump room floor due to chlorine leak. Leak was repaired and room was hosed out prior to inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. No shatterproof mirrors in restrooms.
.2626(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap available in both restrooms.
Apr 17, 2018 6 demerits · 1 violation
Inspector comments: Fence gate that is at the end of the pool while facing out from the pool house is permanently disabled/locked. No path leads to or from the gate, gate is magnet locked as well as chained/padlocked.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy ropes at 54 feet of length, cut to proper length during inspection.
Apr 26, 2017 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor debris in skimmer baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrail at 3 1/2 foot side of pool. Tightened while onsite.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed both throw ropes at 57FT, cut to 50FT while onsite.
Side right gate when facing pool is maintained locked according to operator, was unable to unlock to during inspection to check for proper self closing, self latching.
Apr 27, 2016 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed distance between top of two horizontal members on fence was 40 inches. Pool was constructed prior to 2010.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed ventilation system in eqiupment room not working properly.
May 1, 2015 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmer baskets. Maintain clean.
Apr 24, 2014 4 demerits · 2 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet. Chemicals stored on floor.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower sign not posted. Signed posted during my inspection.