6demerits
CENTRAL PARK AT AYRSLEY
2340 RACHELWOOD DR, Charlotte, NC 28273
Seasonal Swimming Pool · NC permit/State ID 2060501181
Latest result6 demerits
Last inspectedJun 11, 2026
Inspections on record13
On record sinceApr 10, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 10, 2014Lower is betterJun 11, 2026
Inspections & violations
Jun 11, 2026 6 demerits · 1 violation
Inspector comments: Main drain expire: 04/01/2029
Equalizer cover expire: 04/01/2029
Night swimming is not permitted.
Permit Restriction - Flow meter must remain operable. Pump flow must be at least 104 GPM for turnover and cannot exceed 141 GPM for filter limitation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. EHS observed the rope length above the required length. CDI- CPO cut rope to appropriate length. -6-
Apr 28, 2025 0 demerits · 0 violations
Inspector comments: No night swimming.
Pump Hayward SP32950VSP
Main Drain Aquastar 12MFxxx VGBA2017 x2
Equalizers Aquastar 6HPHAxxx VGBA 2017 x4
Pipe Sizes
Skimmer 3” - Skimmer line is 4 inches
Main Drain 4”
Return 3” - Return line is 4 inches
Permit Restriction - Pump must be set at 3450 rpm -or- flow must be at least 104gpm
for turnover and cannot exceed 141gpm for filter limitation with a properly installed and
operational flow meter.
In field plan review completed during inspection. Only change is size of skimmer and return lines.
No violations were recorded for this inspection.
Apr 12, 2024 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope too long. Rope cut to 38’ - required length.
May 24, 2023 8 demerits · 2 violations
Inspector comments: No night swimming permitted.
165 GPM
Pool hours will be from sunrise til sunset.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Opening in fence was greater than 5 “. Area was along the backside of the pool near the pond. CDI- CPO closed area of gate.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Repair cracks in deck near pool wall. Crack observed in deck on right side of pool.
Apr 22, 2022 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Rope length was greater than required. Rope was cut during the inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. - Service gate was not initially latching when closing. Gate was was fixed during the inspection.
Apr 1, 2021 10 demerits · 3 violations
Inspector comments: PDSC verified.
No night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. To be emptied.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed foot hold where brick meets fence at clubhouse. Pool built pre-2010. Eliminate foot holds.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Toilet in men’s restroom needs to be cleaned and possibly unclogged.
Apr 14, 2020 20 demerits · 5 violations
Inspector comments: Pump room floor does not appear to slope to drain. Floor shall slope to drain.
Permit issued for night swimming.
Inspection not signed due to restrictions for COVID-19. Mark Houff present during inspection.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid at 100 ppm. Tested during inspection. 100 ppm is limit for CYA. Lower CYA to not exceed 100 ppm.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Etching on pool walls and pool floor. Recommend plastering pool. No direct hazard to public as current etching does not seem to affect chemistry or cut hazard. Keep pool plaster in good repair.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Vacuum line cover protruding greater than 2". Pool built in 2009. Self-closing cap removed and screw in plug provided.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick on building provides foothold to fence. Located at 34" from ground. Eliminate footholds below 45" in height. Pool built pre-2010.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lights not operable. Pool not approved for night swimming. Repair lights so operable.
Apr 11, 2019 4 demerits · 1 violation
Inspector comments: Observed main drain covers to be different than ones listed on PDSC form. CDI: Covers changed out to correct covers. PDSC form is now in compliance.
No night swimming.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed no extra pump basket. CDI: pump basket provided.
.2518(e) Provide a spare basket for pump.
Apr 26, 2018 8 demerits · 2 violations
Inspector comments: General Comment: Observed 1 of 2 showers not working. Maintain in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 60 feet. CDI, rope adjusted to required length while on-site.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash.
Apr 6, 2017 4 demerits · 1 violation
Inspector comments: Operator (Mark Houff) advised that pool hours are dawn til dusk only; added to posted sign for pool hours.
Please allow up to 3 business days to access permit at Meckpools. charmeck.org. Ensure that permit is posted so that it is visible and remains visible upon entry into pool area.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed some debris in the pool on the interior sides and corners. Maintain clean.
Mar 30, 2016 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed the rope length at 34FT. CDI- Made it 38FT.*NOTE: All Pump, MD, Skimmer, Etc information has been verified.*ACCESS POOL PERMIT ONLINE AFTER 3 BUSINESS DAYS AT HTTP://MECKPOOLS.CHARMECK.ORG*Report emailed to inspectionscharlotte@gmail.com
Apr 15, 2015 6 demerits · 1 violation
Inspector comments: #17 Observed minimal deck cracks extending from pool edge. ** Patch when/ if cracks become worse (ie offsets, etc.)
Note:
- Pool slightly cloudy; however, screws on main drains visible.
- Hot water heater not on at the time of inspection.
POOL PERMIT CAN BE ISSUED.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed 36' throw rope on ring buoy. ** 38' rope required. Corrected while on-site with new rope.
Apr 10, 2014 6 demerits · 1 violation
Inspector comments: . .POOL INSPECTION CONDUCTED DURING DAYTIME. UNABLE TO CHECK POOL LIGHTSACCESS POOL PERMIT ONLINE AFTER 3 BUSINESS DAYS AT HTTP://MECKPOOLS.CHARMECK.ORG
#3 · Water quality: pool water pH −6
Observed pH at 7.1. CORRECTED TO 7.5
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CENTRAL PARK AT AYRSLEY” or State ID 2060501181). Inspection type (routine vs. follow-up) is not published in the county's data.