‹ Back to search

52demerits

HEATHERSTONE II

9255 MEADOW VISTA RD, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060501204
Latest result52 demerits
Last inspectedAug 25, 2026
Inspections on record13
On record sinceJul 8, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02652 Jul 8, 2014: 12Jun 15, 2015: 0Jun 28, 2016: 6Jun 27, 2017: 6May 14, 2018: 6Apr 23, 2019: 4Apr 16, 2020: 0Apr 15, 2021: 4Apr 27, 2022: 10Aug 2, 2023: 4Jul 15, 2024: 6Aug 25, 2026: 0Aug 25, 2026: 52
Jul 8, 2014Lower is betterAug 25, 2026

Inspections & violations

Aug 25, 2026 52 demerits · 13 violations
Inspector comments: Notes: - (1) of 2 gates permanently disabled. Per building code and fire code, 2 gates may be required. Recommend verifying with other trades to ensure second gate can remain permanently disabled. - Hose bib in chemical storage room. Per code enforcement, water supply should not be provided in areas where chemicals are stored. Permit Denied for the following: .2535 - maintain pH at 7.2 to 7.8. .2539 - replace rusted screws in equalizer line covers. .2518 - replace skimmer weir - maintain water level so skimmers functional. .2521 - contrasting color band on steps shall be 2x2 tile .2528 - repair gate to 2" or less underneath and repair meshing to eliminate hazard. .2537 - repair coping at deck and coping closest to pump so offset less than 1/2". .2518 - repair pressure gauge on filter. Matt Yates present during the inspection.
#3 · Water quality: pool water pH −6
Pool pH at 7.0. Maintain at 7.2 to 7.8. Permit denied.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Screws rusted in equalizer line covers on wall. Screws shall be stainless. Replace so secured. Permit denial.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some chipping plaster. Plaster areas where chipped are not sharp and do not appear to present hazard. Plaster shall require repair if worsens.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer without weir closest to steps. Replace weir. Permit denial. Water level low. Pool appears to have a leak. Operator stated they are consistently having to add water. Water level shall be maintained so that skimmers are operable. Permit denial.
#13 · Pool maintenance: contrasting band on steps and benches −4
Pool putty in multiple locations on steps where contrasting tile is covered and not 2" thick. Repair contrasting color band so 2" thick per rule. Permit denial.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring for buoy too long. Cut to 38 ft. during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
>2" under gate. Maintain 2" or less on gate. Permit denial. Damage to meshing on front gate - presents hazard to public due to the metal. Repair. Meshing required due to support beam on gate. Permit denial. Multiple areas of fence >4" from ground to bottom horizontal. Pool built in 2008.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
>1/2" offset between coping and deck at area closest to pump room. 1/2" between coping and deck opposite side of pool also. Permit denial for coping >1/2".
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
No flow meter on 300-29x feeder. Additional feeder in place but lid broken and not in use. Chlorinator shall be NSF approved. Install flow meter on chlorinator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pressure gauge not operable on filter. Repair pressure gauge. Permit denial.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No shelving in chemical storage room to maintain pool chemicals up off the floor. Provide shelving to keep chemicals stored up off the floor. Light burnt out in chemical storage room. Repair light. Dry chemicals in tub in pump room. Store chemicals in approved chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels/hand soap in restrooms. Provide. Restrooms with debris/in need of cleaning. Keep clean.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Some hose bibs without backflow prevention device. Provide backflow preventers on all hose bibs.

View this inspection on the county portal ›

Aug 25, 2026 0 demerits · 0 violations
Inspector comments: Pool scheduled for operating permit inspection. Had been placed on C status. Changed to A status to deny the permit.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 15, 2024 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. SIGNAGE NOT EASILY VISIBLE, WRITTEN IN PEN ON DARK SURFACE CDI - SIGNAGE REWRITTEN IN VISIBLE MARKER.

View this inspection on the county portal ›

Aug 2, 2023 4 demerits · 1 violation
Inspector comments: .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.9. CDI- pH corrected to 7.2.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cracked tile on deck near the pools edge. Fix tile and surrounding deck area.

View this inspection on the county portal ›

Apr 27, 2022 10 demerits · 3 violations
Inspector comments: Night swimming prohibited.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Emergency phone signage with address and telephone number of the pool loose/detaching from the building structure. CPO re-affixed during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Chemical storage room mechanical ventilation not operational and only vent in door - no cross ventilation available. Light fixture in chemical storage room inoperable.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed both restrooms in need of cleaning. .2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in womens restroom.

View this inspection on the county portal ›

Apr 15, 2021 4 demerits · 2 violations
Inspector comments: Observed several ant mounds around where concrete meets grass throughout pool deck area. Recommend to treat to remove. Pre-permit inspection passed. Permit issued. No night swimming.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Facility has a separate chemical storage room but it is not currently being used to store chemicals. Chemicals are being stored in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed fan not properly functioning in what is supposed to be the chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed both restrooms in need of cleaning.

View this inspection on the county portal ›

Apr 16, 2020 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 23, 2019 4 demerits · 2 violations
Inspector comments: PDSC form verified.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. None available.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(j) Provide soap and soap dispenser, no glass, at each sink. No soap available. .2626(m) Keep restrooms and fixtures clean and in good repair. Clean the restrooms and repair the wall in one restroom where it has been removed to access plumbing.

View this inspection on the county portal ›

May 14, 2018 6 demerits · 2 violations
Inspector comments: not swimming is prohibited at this pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. west facing gate has been disabled with brackets and latch mechansim removed.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(m) Keep restrooms and fixtures clean and in good repair. restrooms are dirty. .2626(k) Provide shatterproof mirrors. mirrors in restrooms are not shatterproof.

View this inspection on the county portal ›

Jun 27, 2017 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
Provide an emergency telephone at pool with a sign that indicates the phone number and the address. Observed the telephone number listed incorrectly. CDI- correct telephone number was recorded.

View this inspection on the county portal ›

Jun 28, 2016 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain the deck in good repair and free of trip hazards. Observed a small gap in between brick tiles near the pool rail. Recommend re-caulking here to prevent any trip hazards.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Maintain the restrooms clean and in good repair. Observed damaged to the womens restroom door frame.

View this inspection on the county portal ›

Jun 15, 2015 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 8, 2014 12 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HEATHERSTONE II” or State ID 2060501204). Inspection type (routine vs. follow-up) is not published in the county's data.