8demerits
ANTIQUITY SWIM CLUB
1317 LOVERS LAWN TRCE, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060501207
Latest result8 demerits
Last inspectedMay 5, 2026
Inspections on record13
On record sinceMay 6, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 6, 2014Lower is betterMay 5, 2026
Inspections & violations
May 5, 2026 8 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING.
Permit Restriction: Flow meter must remain operable. Flow required at 240 gpm to 250 gpm to meet turnover and pipe size limitations. Flow greater than 356 exceeds min drains. Suction Hazard.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed one throw rope > 50’. CDI cut to 50’ by CPO.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. Upstairs restroom floors are slick.
Apr 24, 2025 0 demerits · 0 violations
Inspector comments: POOL RESTRICTIONS
FLOW MUST REMAIN BETWEEN 240GPM AND 250GPM TO MEET TURNOVER PIPE SIZE LIMITATIONS AND DRAIN COVER FLOW RATES.
OBSERVED FLOW AT 242GPM DURING INSPECTION.
EQUALIZER COVERS EXPIRE 12/2025
No violations were recorded for this inspection.
Apr 16, 2024 2 demerits · 1 violation
Inspector comments: PERMIT RESTRICTION:
Flow meter must remain operable. Flow required at 240 GPM to 250 GPM to meet turnover pip size limitations and drain Cover Flow restrictions.
Note: PIC: Mr. Lance Ricker present during initial permit inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Provide at least one handrail on steps.- There are three handrails on steps. One of them by itself on the other side is little loose, need repair and secure it tight.
Apr 19, 2023 10 demerits · 2 violations
Inspector comments: Night swimming is prohibited at this pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed a few missing weirs. CDI
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed 2 throw ropes > 50’.
CDI
Apr 20, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS DURING INSPECTION.
No violations were recorded for this inspection.
Apr 15, 2021 12 demerits · 3 violations
Inspector comments: Taylor Mastin on site. No night swimming.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
pH observed at 6.8
CDI pH corrected to 7.2
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
observed debris in skimmers. CDI
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair.
observed water leak at mens restroom toilet and womens restroom hand sink
Apr 22, 2020 0 demerits · 0 violations
Inspector comments: Due to covid 19 restrictions, no signature required. Danny present.
No violations were recorded for this inspection.
Apr 17, 2019 2 demerits · 1 violation
Inspector comments: CPO Danny Richards was present during the inspection.
Night Swimming is not permitted.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
(.2512) - Provide back flow prevention. - Observed no back flow prevention device on the hose bib located on the pool deck.
May 9, 2018 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed debris in skimmers. Cleaned out during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrails and ladders. Tightened during pool inspection.
May 5, 2017 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose handrail. Advised to tighten.
May 11, 2016 14 demerits · 4 violations
Inspector comments: .Observed phone number to emergenct phone faded but still legible. CPO filled in.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 3 weirs missing. CDI-replaced.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrail not installed correctly. CDI-repaired.
Observed loose handrails and ladders.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope exceeding 50FT. CDI-shortened to 50FT.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet.
May 8, 2015 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed electrical box as foot hold to the right of the entrance gate. Maintain fence free from foot holds.
May 6, 2014 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length to be greater than 50 feet. CDI-rope length shortened to 50 ft.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ANTIQUITY SWIM CLUB” or State ID 2060501207). Inspection type (routine vs. follow-up) is not published in the county's data.