‹ Back to search

0demerits

METROPOLITAN AT MIDTOWN

1100-E METROPOLITAN AVE, Charlotte, NC 28204
Seasonal Swimming Pool · NC permit/State ID 2060501208
Latest result0 demerits
Last inspectedJul 1, 2026
Inspections on record16
On record sinceApr 22, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Apr 22, 2014: 10Apr 14, 2015: 6Apr 12, 2016: 0Apr 21, 2017: 0Apr 30, 2018: 4Apr 10, 2019: 0Apr 14, 2020: 0May 28, 2021: 6Aug 11, 2021: 0Apr 12, 2022: 8Apr 19, 2023: 18Apr 26, 2023: 12Apr 9, 2024: 12Apr 24, 2025: 16May 16, 2025: 0Jul 1, 2026: 0
Apr 22, 2014Lower is betterJul 1, 2026

Inspections & violations

Jul 1, 2026 0 demerits · 0 violations
Inspector comments: No demerits noted. Permit Restriction: Flow meter must remain operable. Flow required at 14 gpm to 84 gpm to meet turnover and flow restriction of the filter. Flow greater than 143 gpm exceeds the equalizer line covers and flow greater than 150 gpm exceeds the main drains. Suction Hazard. Note: Door on to pool deck not self-latching. Glass mirror and light removed from the kitchen. Kitchen considered pool deck. If facility wishes to put glass in the kitchen, doors must be made to self-latch self-close. No night swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 16, 2025 0 demerits · 0 violations
Inspector comments: Inspection conducted with operator Pierce Sawyer. All permit items found to be in compliance. Permit issued. No night swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 24, 2025 16 demerits · 3 violations
Inspector comments: Permit denial and Q status issued for chlorine levels at 0.2ppm and emergency phone sign address not matching with what 911 had in system. Correct all items and contact main office at 980-314-1620 and pay $100 for reinspection fee. No night swimming Note: Door leading to pool deck not self-latching and has no audible alarm. If wanting to put glass in kitchen doors must be made to self-latch self close. Inspection conducted with CPO Pierce Sawyer.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine levels at 0.2ppm. Permit denial. Q status isssued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture and planters less than 6’ away from pool deck. -CDI- CPO relocated items to provide at least 6’ of clearance.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Address listed on emergency phone sign did not match with what 911 had in system. 911 system has 1100 Metropolitan Ave instead of 1100-E Metropolitan Ave as what is listed on permit. Pool company needs to notify phone company to have them add suite number to system. Permit denial. Q status issued.

View this inspection on the county portal ›

Apr 9, 2024 12 demerits · 3 violations
Inspector comments: Doors opening directly onto pool deck are not self-closing/self latching and have no audible alarm. Permitted as long as no glass is in kitchen area.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed no slip-resistant tread on ladders. -CDI- CPO provided slip resistant treads. .2521 Install ladders per manufacturer instructions. Observed ladder not secured to pool deck. -CDI- CPO secured ladder to pool deck.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed broken hook on body hook. -CDI- CPO provided new body hook. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope length at 16’9”. -CDI- CPO corrected rope length to 15’.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool chairs less than 6’ away from pool deck. -CDI- CPO relocated items to provide at least 6’ of clearance.

View this inspection on the county portal ›

Apr 26, 2023 12 demerits · 3 violations
Inspector comments: Pool does not plan to do night swimming. Pool will close at 8:30p. Night swimming is prohibited.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH levels at 7.0. Corrected to 7.2 during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed lawn chairs < 6ft for pool edge. Chairs moved to provide 6ft walking space.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed a chemical bag stored on the floor. Moved off of the floor.

View this inspection on the county portal ›

Apr 19, 2023 18 demerits · 3 violations
Inspector comments: Permit denial issued for # 2 & #22. Q status issued. $100 reinspection fee must be paid and items need to be corrected before permit can be issued. Call the main office at 980-314-1620 to request a reinspection and pay fee.
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. Observed chlorine levels bleached out test reagents and are at toxic levels well above 10ppm. Permit denial. Q status issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope shorter than 15ft length required for pool. CDI: new rope was attached and corrected to 15ft during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed address on emergency phone sign did not match with what 911 had on file. 911 is showing address located in building across the street. Permit denial. Q status issued.

View this inspection on the county portal ›

Apr 12, 2022 8 demerits · 2 violations
Inspector comments: No night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy with damaged ropes around the edges. Corrected on site: new ring buoy provided.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed pipe for backwash down in backwash pit. Provide air gap.

View this inspection on the county portal ›

Aug 11, 2021 0 demerits · 0 violations
Inspector comments: No violations observed

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 28, 2021 6 demerits · 1 violation
Inspector comments: Pool permit denied due to incorrect 911 location information.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Location identification was not correct. Location provided by 911 operator during location check was 1111 Metropolitan Avenue which is located across the street from the pool. The property manager was able to determine that incorrect location information for pool phone was given to phone company. The property manager was able to correct the phone location with the phone company but was told that information would not be updated with 911 until at least 24 hours later.

View this inspection on the county portal ›

Apr 14, 2020 0 demerits · 0 violations
Inspector comments: General Comment: Repair/replace damage pressure gauge in pump room. Gauge was still observed to be properly working.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 10, 2019 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 30, 2018 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladder fixture on the side wall of the pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed calcium chloride bags stored on the floor of the chemical closet.

View this inspection on the county portal ›

Apr 21, 2017 0 demerits · 0 violations
Inspector comments: No Violations. Pre-permit inspection conducted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 12, 2016 0 demerits · 0 violations
Inspector comments: Pump was changed a few days ago. New PDSC form has been submitted. Permit conditional based on approval of PDSC form.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 14, 2015 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Provide at least 6 foot clearance around the pool. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Store chemicals in chemical storage room.

View this inspection on the county portal ›

Apr 22, 2014 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
No rubber end caps on ladder rails. Provide.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Large flower planters within 6' of pool edge. Maintain 6' clearance. COS
#18 · Premises: lifeguards present or warning signs posted −4
Improper sized font on warning signs. Provide at least 1" lettering "Adults should not swim alone", and " Children should not use the pool without adult supervision". COSGeneral Comments: At time of inspection the Hallway/amenities room door counts as the main barrier and is self closing/self latching. The amenities room will be counted as part of the pool deck. No glass shall be on/in pool deck. A staff member will be in contact to determine if the french doors need to be self latching. Roger Rockholt present.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “METROPOLITAN AT MIDTOWN” or State ID 2060501208). Inspection type (routine vs. follow-up) is not published in the county's data.