HAMPTON INN AND SUITES

10305 WILMINGTON ST, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060501235
Latest result6 demerits
Last inspectedMay 21, 2026
Inspections on record12
On record sinceMay 14, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 May 14, 2014: 6May 7, 2015: 0May 19, 2016: 0May 12, 2017: 4May 16, 2018: 6May 7, 2019: 10May 27, 2021: 14May 16, 2022: 18May 8, 2023: 10May 15, 2024: 0May 14, 2025: 6May 21, 2026: 6
May 14, 2014Lower is betterMay 21, 2026

Inspections & violations

May 21, 2026 6 demerits · 1 violation
Inspector comments: Pool operating hours will be from 9am - 10pm. Approved for night swimming 6/12/2025
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed posted Emergency Phone number on wall not on file with 911 Dispatch. Hotel establishment recently switched to automated phone service at front desk. Phone number listed with 911 Dispatch dials directly to Emergency Phone. CDI - Posted emergency phone number on wall was updated to represent phone number that is on file with 911 Dispatch and will dial directly to phone if used.

View this inspection on the county portal ›

May 14, 2025 6 demerits · 1 violation
Inspector comments: Pool operating hours will be from 9am - 10pm. Pool lights were on and operating. Photos were taken showing sufficient lighting of pool deck and drains. Emergency telephone rings to front desk which is staffed 24/7. Emergency phone has direct phone number. Pool operator has been advised to post direct phone number at emergency phone. Approved for night swimming 6/3/2021
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope in excess of 50ft. CDI - Buoy rope was shortened to required 36ft during inspection.

View this inspection on the county portal ›

May 15, 2024 0 demerits · 0 violations
Inspector comments: No violations noted during inspection. Pool operating hours will be from 9am - 10pm. Pool lights were on and operating. CPO will provide photos showing sufficient lighting of pool deck and of drains.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 8, 2023 10 demerits · 2 violations
Inspector comments: Pool operating hours will be from 9am - 10pm. Pool lights were on and operating. CPO provided photos showing sufficient lighting of pool deck and of drains.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed two missing weirs in pool. Replace
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope to be in excess of 36ft. CDI - Buoy rope was shortened to be in compliance.

View this inspection on the county portal ›

May 16, 2022 18 demerits · 4 violations
Inspector comments: Pool operating hours will be from 9am - 10pm. Night swimming visit will be required. Could not verify night swimming on site due to 2 pool lights out around pool. Night swimming is not permitted at this time. CPO will send photo for verification of sufficient lighting.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
REPEAT VIOLATION: .2518(k) Replace missing weirs. One weir missing out of 3 at 3' depth. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
REPEAT VIOLATION: Ring buoy rope observed > 36ft. Maintain rope at 36'. Rope cut to 36ft. Corrected during inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
REPEAT VIOLATION: .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed trash can, 2 planters, and a cigarette disposal can within 6ft of pool deck edge. CDI: all items moved back and relocated to provide 6ft deck clearance.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
REPEAT VIOLATION: .2518(g) Keep flow meter operational. Observed flow meter stuck to bottom. Corrected during inspection.

View this inspection on the county portal ›

May 27, 2021 14 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope was 60'. Maintain rope at 36'. Corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 6' of clearance around pool.. Several chairs were within 6'. There is not enough clearance for furniture on the south end (furthest from pool entrance) of pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing at 3' depth. Replace.

View this inspection on the county portal ›

May 7, 2019 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy provided with rope length measuring too short; CDI proper ring buoy provided with correct rope length.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool chairs stored within 4 feet of pool edge; CDI chairs moved to approved location.

View this inspection on the county portal ›

May 16, 2018 6 demerits · 2 violations
Inspector comments: Bolts on the body hook were turned around so wing nuts faced outward. Facility has two ring bouys and one of the ropes was 34.5 feet instead of the required 36 feet on the other ring bouy.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Weir is missing at the shallow end skimmer. CPO replaced during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail at the shallow end steps is loose.

View this inspection on the county portal ›

May 12, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 6 feet of clearance from pool edge. Some chairs were located too close to pool edge.

View this inspection on the county portal ›

May 19, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 7, 2015 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 14, 2014 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer equalizer lines plugged. Corrected during inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed hot water in restrooms at 114 f. Temper hot water to less than 110 F at the pool area restrooms.

View this inspection on the county portal ›