Apr 14, 2026 34 demerits · 7 violations
Inspector comments: POOL IS NOT PERMITTED FOR NIGHT SWIMMING.
FLOW METER MEASUREMENT: 100 GPM
After discussion with Senior K. Rudisill, drain covers match PDSC form and are confirmed to be 2008 Lawson MLDFGD1212.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.1 according to EHS test kit. CDI: CPO raised pH to 7.3 by end of inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed rusted screws one of the drain covers. CDI: CPO replaced with new stainless steel screws by end of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope over 37FT in length. CDI: CPO adjusted rope to be 37FT.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed latch less than 54” with key pad no in use and gate able to be opened with latch only. CDI: CPO replaced batteries in key pad and gate now latches and locks with key pad in use.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed some cracking in deck on far side of pool. Repair.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Sign posted next to emergency phone observed lacking location’s address to emergency phone. - CDI - CPO wrote in address on sign in permanent marker. REPEAT
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap or soap dispenser in restroom.
.2526(l) Provide toilet paper and dispensers in restrooms. Observed no toilet paper in restroom.
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed toilet and sink in need of cleaning.
Apr 23, 2025 16 demerits · 3 violations
Inspector comments: Inspection conducted with CPO, present. PDSC information and permit restrictions verified:
General Comments:
*Observed chlorine to be over 10. Recommend to reduce chlorine to avoid skin irritation.
*Observed water leak from vent pipes in pump room.
No night swimming. Permit issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed throw rope tied to a residential ring buoy. CDI - CPO replaced with USCG approved ring buoy during inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope exceeding 37”. CDI by CPO.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck chairs 4 ft from edge of pool. CDI - PIC moved all deck chairs to at least 6 ft of clearance around the pool. REPEAT VIOLATION.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Sign posted next to emergency phone observed lacking location’s address to emergency phone. - CDI - CPO wrote in address on sign in permanent marker.
Apr 22, 2024 10 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Deck chairs were 4 ft from edge of pool. CDI PIC moved all deck chairs to at least 6 ft of clearance around the pool.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Sign posted next to emergency phone observed lacking phone number to emergency phone. - CDI - CPO wrote in phone number on sign in permanent marker.
Apr 10, 2023 10 demerits · 2 violations
Inspector comments: Pool wall above water line in need of cleaning.
NIGHT SWIMMING NOT PERMITTED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. - Observed only access gate to stick on concrete preventing gate from self closing. - CDI - CPO shaved down gate to prevent sticking and allow gate to self close and self latch.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Sign posted next to emergency phone observed lacking phone number to emergency phone. - CDI - CPO wrote in phone number on sign in permanent marker.
May 18, 2022 2 demerits · 1 violation
Inspector comments: New PDSF form verified.
No night swimming.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(l) Provide toilet paper and dispensers in restrooms. No toilet paper in restroom.
Jun 7, 2021 0 demerits · 0 violations
Inspector comments: PDSC form updated. Facility in compliance.
No violations were recorded for this inspection.
Aug 10, 2020 8 demerits · 2 violations
Inspector comments: No signature due to COVID-19. Inspection completed with Aristotle Daka and Ashirov Shamil.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 of 4 weirs installed. CDI- 3 additional weirs were installed today.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed area between pool bathroom and fence where a 5" gap exists. CDI- wood installed between barrier to decrease gap size.
Apr 29, 2019 16 demerits · 4 violations
Inspector comments: PDSC reviewed and confirmed at inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed missing weir at deep end left side skimmer. CPO to replace this afternoon.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
During the beginnning of the inspection, the emergency telephone was not properly working and the 911 operator could not be heard well. CDI. The CPO repaired the phone and 911 was called again and was clear.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Observed flow meter not properly working at time of inspection. CDI. The CPO repaired the flow meter during the inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(j) Provide soap and soap dispenser, no glass, at each sink.
No soap provided in the bathhouse restroom.
Apr 20, 2018 0 demerits · 0 violations
Inspector comments: I did not find any issues with the pool
No violations were recorded for this inspection.
May 10, 2017 4 demerits · 1 violation
Inspector comments: PDSC form had to be resubmitted with the correct model numbers for equilizers. Faxed in during inspection but the permit will not be issued until this form has been approved. Once it has been approved, the permit will be posted within 3 days.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one gate that was not self closing- grass dug up so that it would self close and self latch no matter how wide it was opened. Highly recommend providing some type of gate stop on the back side so that the regrowth of grass will not impede the gate in the future.
Apr 20, 2016 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 28, 2015 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS POST PERMIT IN PUBLIC VIEW
No violations were recorded for this inspection.
May 7, 2014 0 demerits · 0 violations
No violations were recorded for this inspection.