ANSLEY FALLS APARTMENTS

6310 ANSLEY FALLS DR, Charlotte, NC 28217
Seasonal Swimming Pool · NC permit/State ID 2060501251
Latest result10 demerits
Last inspectedJun 5, 2026
Inspections on record14
On record sinceMay 9, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01326 May 9, 2014: 4Apr 28, 2015: 24May 13, 2016: 20Apr 17, 2017: 8May 11, 2018: 8Jun 27, 2019: 20Aug 14, 2020: 6May 21, 2021: 12Jul 1, 2022: 16May 24, 2023: 16May 22, 2024: 6Jun 3, 2025: 0Apr 14, 2026: 26Jun 5, 2026: 10
May 9, 2014Lower is betterJun 5, 2026

Inspections & violations

Jun 5, 2026 10 demerits · 3 violations
Inspector comments: PDSC forms verified during today’s inspection with CPO Ivan Peña present. All previous critical violations corrected. General comments: - Observed pool plaster deteriorating on several areas in the pool. Correct by 2027 season. - Observed cover plate (mounting hardware) detached from hand rail anchor. Repair or remove. Not permitted for night swimming. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 skimmer missing it’s weir. Provide.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed lounge chairs staged 4 ft from edge of pool. CDI - CPO pushed back chairs to provide clear walking space around the pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed bags of sodium bicarbonate stored on the floor in chemical storage room. CPO advised to remove from floor. .2534(6) Provide sufficient lighting in chemical storage room. Observed inoperable lighting in chemical storage room provide.

View this inspection on the county portal ›

Apr 14, 2026 26 demerits · 6 violations
Inspector comments: PDSC forms verified during today’s inspection. Permit denied. Items denoted holding up permit: - .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed new pump installed without prior approval. - .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazards at edges of skimmer cover at 3 1/2 ft and under hand rails at 4 1/2 ft. - .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Signage alerting “No Lifeguard on Duty” measured < 4" lettering. Observed “No Lifeguard on Duty” measuring at 2.5" lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed advisory measuring at 0.5" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed advisory measuring at 0.5" lettering. General Comment: Observed pool plaster deteriorating on several areas in the pool. Correct by 2027 season. Once violation is corrected, return visit fee may be paid by calling Environmental Health Department at 980-314-1620
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed new pump installed without prior approval.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers full of debris.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed opening to be > 4"x4" between vertices on 2x access gates. CDI by CPO.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazards at edges of skimmer cover at 3 1/2 ft and under hand rails at 4 1/2 ft.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Signage alerting “No Lifeguard on Duty” measured < 4" lettering. Observed “No Lifeguard on Duty” measuring at 2.5" lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed pool rules signage measuring at 0.5" lettering.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operating.

View this inspection on the county portal ›

Jun 3, 2025 0 demerits · 0 violations
Inspector comments: Pool open for 2025 pool season. No night swimming Only violation pool rope was greater than 36 feet. Pool operator cut the rope to the required length. Unable to put violation into inspection due to error with smart form. Overall, problem corrected. Ringer was turned off on phone. Switched to on position phone now rings.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 22, 2024 6 demerits · 1 violation
Inspector comments: Night swimming not permitted.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring 23 ft. CDI, new throw rope provided measuring 36 feet.

View this inspection on the county portal ›

May 24, 2023 16 demerits · 4 violations
Inspector comments: Inspection conducted with CPO, Derek Sutton present. PDSC form and permit restrictions verified. EHS verified CPO information. All non-compliant items corrected onsite with exception of 1 of 4 missing weirs remaining. Night swimming is not permitted. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers full of debris. .2518(k) Replace missing weirs. Observed 3 of 4 missing weirs. -4-
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed opening to be greater 4"x4" on 2x access gates. -4-
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazards at edges of 2x skimmer covers and missing piece of deck drain cover to be > 1/2. -4-
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. No available signage alerting “No Lifeguard on Duty”. -4-

View this inspection on the county portal ›

Jul 1, 2022 16 demerits · 4 violations
Inspector comments: Verified that there was a teal dot on the equalizer cover and blue dot on main drains.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed pool debris. Needs to be cleaned.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket. - Observed skimmers missing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed rope length at 32’. Rope needed to be 36’, replaced.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. - Observed chemicals stored on the floor.

View this inspection on the county portal ›

May 21, 2021 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers full and floating debris in pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladder on clubhouse side missing end cap
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed phone number posted on emergency phone not what 911 listed. Verified number 911 had listed rang back to emergency phone. CDI PIC changed number to correct number and posted on emergency phone.

View this inspection on the county portal ›

Aug 14, 2020 6 demerits · 2 violations
Inspector comments: no night swimming phone had some static but 911 could hear me
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
one weir missing by ladder, clean baskets
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
ladder has crack around concreate with chipping around the base

View this inspection on the county portal ›

Jun 27, 2019 20 demerits · 5 violations
Inspector comments: Issued permit. No Night Swsimming. *Note: Magnet latches on gates less than 45" in height, protruding 1.5" then separate piece attaches. Did not deem this a "horizontal" less than 45" in height. No corrective action. *Note: Watch for trees creating horizontals less than 45" in height. Especially back left near chemical storage.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing at time of inspection. .2518(k) Replace missing weirs. Operator replaced weir. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Chairs and umbrella in front of body hook and buoy, blocking access. .2530(a) Lifesaving equipment should be conveniently located. Operator moved items blocking emergency equipment. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from clubhouse by restrooms not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator corrected to self close, self-latch. Windows in internet cafe area not alarmed and open greater than 4" onto pool deck. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Operator installed screws to correct window opening greater than 4".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 6' of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bags of chemicals on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.

View this inspection on the county portal ›

May 11, 2018 8 demerits · 2 violations
Inspector comments: No night swimming visit required. Pool opening from dawn to dusk.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed some skimmers with debris. CDI: cleaned during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed areas of fence only measuring 46" high due to pine straw piled up on outside of fence. CDI: pine straw was moved back and now all areas around fence measuring 48" high.

View this inspection on the county portal ›

Apr 17, 2017 8 demerits · 2 violations
Inspector comments: Some Equalizer cover screws appear to be rusted. Replace with brass screws per manufacturer. Equalizer covers are however secured to the wall properly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some areas around fence observed less than 48" due to pine needles. Pine needles moved during inspection and fencing is now 48" high.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Various areas on pool deck observed with minor cracks. Repair in the furture.

View this inspection on the county portal ›

May 13, 2016 20 demerits · 4 violations
Inspector comments: Pre - permit inspection passed. PDSC form needs to be re-submitted for equalizer covers and approved prior to receiving permit.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris inside surface skimmers. CDI - Cleaned during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length greater than required rope length of 36Ft. CDI - Rope cut to required length during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed some spots around fence 47 inches high due to pine straws. Provide at least 48 inches. CDI - Pool operator in process of removing pine straws.
#22 · Premises: emergency telephone provided −6
Observed emergency phone number unclear. CDI - Phone number written in during inspection.

View this inspection on the county portal ›

Apr 28, 2015 24 demerits · 5 violations
#3 · Water quality: pool water pH −6
Observed pool ph at 6.8. Maintain pool ph between 7.2-7.8. CDI, operator was able to adjust ph to 7.3 while on property.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets accumulating debris.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 38 feet. CDI, operator adjusted throw rope to required length while on site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 1 gate not magnet not catching. CDI, operator adjusted gate magnet to properly latch when shut while on-site.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain required deck clearance around pool deck. Observed pool chairs less than 6 feet from pool edge. CDI, pool chairs relocated.

View this inspection on the county portal ›

May 9, 2014 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean skimmer basketGENERAL COMMENT: Highly recommend providing an additional shower before entering pool sign on entrance gate near fittness room entrance. Recommend adjusting timing on magnetic latching mechanism to 5-10seconds. It is taking about 20 seconds for magnetic mechanism to activate. **THIS IS NOT A PERMIT** PERMIT WILL BE ISSUE ONCE PAYMENT IS RECEIVED! Visit meckpools.charmeck.org to obtain a copy of permit!

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ANSLEY FALLS APARTMENTS” or State ID 2060501251). Inspection type (routine vs. follow-up) is not published in the county's data.