‹ Back to search

4demerits

CAROLINA VILLAGE AMENITIES CENTER

14214 GREEN BIRCH DR, Charlotte, NC 28134
Seasonal Swimming Pool · NC permit/State ID 2060501254
Latest result4 demerits
Last inspectedApr 16, 2026
Inspections on record13
On record sinceMay 14, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 May 14, 2014: 8Apr 1, 2015: 4Jun 3, 2016: 8Jun 27, 2017: 12Apr 13, 2018: 6Apr 24, 2019: 4May 12, 2020: 4Apr 13, 2021: 0Apr 19, 2022: 6Apr 21, 2023: 0Apr 16, 2024: 0Apr 29, 2025: 4Apr 16, 2026: 4
May 14, 2014Lower is betterApr 16, 2026

Inspections & violations

Apr 16, 2026 4 demerits · 1 violation
Inspector comments: Shower works but shower head fell off. Toilet in male restrooms are leaking. No Restrictions , no night swimming. Permit was granted walked with David.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning

View this inspection on the county portal ›

Apr 29, 2025 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operational. CDI new flow meter installed and working correctly.

View this inspection on the county portal ›

Apr 16, 2024 0 demerits · 0 violations
Inspector comments: No demerits taken.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 21, 2023 0 demerits · 0 violations
Inspector comments: No demerits taken

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 19, 2022 6 demerits · 1 violation
Inspector comments: David Schult present during inspection. Rope length corrected to 50 ft during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length at 60 ft. Field manual states rope length should be 50 ft. CDI, rope length shortened to 50 ft.

View this inspection on the county portal ›

Apr 13, 2021 0 demerits · 0 violations
Inspector comments: Michael present during the inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 12, 2020 4 demerits · 1 violation
Inspector comments: No signature needed due to COVID-19 guidelines. Permit Conditions: “Issuance of a permit by this department does not negate closure required by Executive Order No. 138 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Maintain weirs in good repair. Observed one weir stuck to the sides of the skimmer unable to move and another weir broken. Corrected during inspection. Both weirs were replaced.

View this inspection on the county portal ›

Apr 24, 2019 4 demerits · 1 violation
Inspector comments: Ensure that permit remains visible. Night swimming is not permitted at this pool. ** CPO unable to to sign due to set of afternoon appointments conflicts.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Diagonal members on fence and/or gate shall not exceed 1.75 inches. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Screw missing from bottom horizontal that attached it to the main support post next to gate on the parking lot side. Missing screw allowed lower horizontal to lifted and separated greater than 5" from the bottom and more than 2" between diagonals. CDI- CPO repaired the fencing immediately. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Electrical supports and posts located directly outside of the fence around the perimeter of the fence creating footholds and decreasing the 45" between horizontals. Pool was constructed pre-2010.

View this inspection on the county portal ›

Apr 13, 2018 6 demerits · 1 violation
Inspector comments: Observed meshing attached to part of gate near extenstion (far left side of pool). Pool is in compliance with foot holds. Operator informed it was a temporary fix and the gate company would be out to put in bottom barriers equivalent to the other part of the pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope greater than 50 feet. CDI Operator cut to 50 feet

View this inspection on the county portal ›

Jun 27, 2017 12 demerits · 2 violations
Inspector comments: Current PDSC form lists Aquastar 6 HP as equalizer covers and a total of 6 skimmers. Pool has 8 skimmers with Aquastar 8HP EQ covers. Operator started filling out PDSC form while on-site. Operator shall submit new PDSC form and have approved form within 3 business days or lead to permit suspension.
#3 · Water quality: pool water pH −6
Observed pool ph at 6.9. CDI, operator adjusted to 7.3 while on-site.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 52 feet. CDI, operator adjusted to correct length. Observed no body hook on site. CDI, operator arrived with body hook.

View this inspection on the county portal ›

Jun 3, 2016 8 demerits · 2 violations
Inspector comments: #8: General Comment: Missing one (1) weir. Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ensure all ladders are tight and secure. Check frequently. Missing bumper on ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy not USCG approved. Corrected by replacing.

View this inspection on the county portal ›

Apr 1, 2015 4 demerits · 2 violations
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed pipes unlabeled. CDI- Pipes were labeled.Ensure all pipes in the pump room are labeled.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed 1 toilet in each rest room not working. The toilet in the women's room has been corrected.Ensure all toilets are working.

View this inspection on the county portal ›

May 14, 2014 8 demerits · 2 violations
Inspector comments: NOT A PERMIT; PDSC MUST BE SENT TO MCHD BEFORE PERMIT IS ISSUED; PDSC FORMS CAN BE FOUND AT: MECKPOOLS.CHARMECK.ORG
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
~~4 FT OF CAULK NEEDS REPLACING
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
FLOW METER STUCK

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CAROLINA VILLAGE AMENITIES CENTER” or State ID 2060501254). Inspection type (routine vs. follow-up) is not published in the county's data.