‹ Back to search

4demerits

BALLANMOOR

18314 LILLIESLEAF GLENN LN, Charlotte, NC 28277
Seasonal Swimming Pool · NC permit/State ID 2060501258
Latest result4 demerits
Last inspectedMay 13, 2026
Inspections on record14
On record sinceApr 17, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Apr 17, 2014: 0Apr 23, 2015: 2May 16, 2016: 0May 10, 2017: 4May 16, 2018: 8Apr 17, 2019: 6Apr 7, 2020: 4Apr 8, 2021: 4Apr 14, 2022: 4Apr 19, 2023: 8Apr 17, 2024: 28Apr 19, 2024: 6May 9, 2025: 8May 13, 2026: 4
Apr 17, 2014Lower is betterMay 13, 2026

Inspections & violations

May 13, 2026 4 demerits · 1 violation
Inspector comments: No night swimming. Meet all restrictions. Permit granted. Walked with Alex New Pump Pentair EQK500, 5 hp pump Aquastar FM40 flow meter reading the above flow range. Main Drain, skimmer and return line all 4 pipe coming out of ground. (2) Lawson 2008 MLD-SG-1818 drain covers. (7) skimmers with (2) Aquastar A10RCFRxxx 2017 EQ line covers on floor and (5) Aquastar 6HPHAxxx 2017 EQ line covers on the wall. (2) Pentair TR140C filters 12 floor returns. All of the above checked out.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers with debris.

View this inspection on the county portal ›

May 9, 2025 8 demerits · 2 violations
Inspector comments: Permit Restriction: Pump must remain at 3450 RPM or flow meter is required operable with flow at least 160 gpm to meet turnover. EHS observed pump running at 3450 RPM and flow meter was at 175 gpm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 2 of 7 skimmers missing weirs. Replace missing weirs.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. 2 lounge chairs observed within 6 feet of pool. Operator relocated chairs during inspection.

View this inspection on the county portal ›

Apr 19, 2024 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed taupe colored phone box and no signage. Blends in with pool house. CDI-emergency phone sign installed

View this inspection on the county portal ›

Apr 17, 2024 28 demerits · 6 violations
Inspector comments: Pay reinspection fee, then call for reinspection
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed main drain for feature missing screw
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool excessively dirty with leaves and pollen.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 missing weirs
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed buoy with dry rotted broken rope.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. Observed one corner of safety sign broken and not secure.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Flow meter be capable of measuring 1.5 times the design flow rate. Observed flow meter not working

View this inspection on the county portal ›

Apr 19, 2023 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor floating debris in skimmers.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed an inoperable flow meter, flow meter bobber stuck at the bottom of the flow meter. Corrected on site and bobber is no longer stuck at bottom of flow meter.

View this inspection on the county portal ›

Apr 14, 2022 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating debris in skimmers.

View this inspection on the county portal ›

Apr 8, 2021 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed cleaning needing to be done inside skimmers and skimmer baskets.

View this inspection on the county portal ›

Apr 7, 2020 4 demerits · 1 violation
Inspector comments: no night swimming
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
eye ball missing but corrected during inspection

View this inspection on the county portal ›

Apr 17, 2019 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
Observed the pH at 6.9. Corrected-Now at 7.4. .2535(1) Maintain pH at 7.2 to 7.8. *NO Night Swimming until Inspector returns to verify adequate night lighting. *Report emailed to katieb@aquatechpm.com

View this inspection on the county portal ›

May 16, 2018 8 demerits · 2 violations
Inspector comments: Report emailed to Katie Buttcher, verified receipt during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed duck feathers present in one area of the feature section of the pool. Pool must be cleaned before opening.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed duck debris on one section of the pool deck. Area must be cleaned before opening and monitored for accumulation.

View this inspection on the county portal ›

May 10, 2017 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor.

View this inspection on the county portal ›

May 16, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 23, 2015 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilets would not flush. Water not turned on. Corrected during inspection. Need something to dry hands with in men's restroom.

View this inspection on the county portal ›

Apr 17, 2014 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BALLANMOOR” or State ID 2060501258). Inspection type (routine vs. follow-up) is not published in the county's data.