‹ Back to search

14demerits

SILOS SOUTH END APARTMENTS

131 POINDEXTER DR, Charlotte, NC 28203
Seasonal Swimming Pool · NC permit/State ID 2060501285
Latest result14 demerits
Last inspectedApr 24, 2026
Inspections on record15
On record sinceApr 4, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0714 Apr 4, 2014: 2Jun 2, 2014: 0Jun 8, 2015: 2May 4, 2016: 4May 1, 2017: 4May 15, 2018: 10May 23, 2019: 10Apr 9, 2020: 0Apr 7, 2021: 0Jun 7, 2022: 6May 1, 2023: 0May 10, 2023: 0Apr 16, 2024: 14Apr 9, 2025: 0Apr 24, 2026: 14
Apr 4, 2014Lower is betterApr 24, 2026

Inspections & violations

Apr 24, 2026 14 demerits · 3 violations
Inspector comments: PERMIT ISSUED. POOL IS NOT PERMITTED FOR NIGHT SWIMMING FLOW METER MEASUREMENT: 70 GPM PDSC form states that feature pump is a Hayward SP3207x10 HP=1. Feature Pump observed in field is Hayward SP 3205EE HP=1/2. CPO stated that there have been no pump changes and that the PDSC form was filled out incorrectly. Caribbean Pools submitted a new PDSC form with correct information while EHS was on-site. PEHS W. Harrison received the new PDSC form and gave guidance to EHS during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed inactive vacuum line in pool with solid screw in fitting in place. No self-closing self-latch cover observed. CDI: Line appears to be permanently disable and CPO states it is disabled permanently. Screw in solid fitting is secured in wall. Pool has one other vacuum line that is in operation with proper cover that self-closes and self-latches with tool to open. Vacuum is turned off.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope measuring over 50FT. CDI: CPO adjusted rope to measure 50 FT.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed far gate by restrooms unable to self close due to hinge issues causing the gate to get stuck on the concrete when opened. CDI: CPO adjusted hinges to lift gate off of concrete to allow for self-closing, self-latching.

View this inspection on the county portal ›

Apr 9, 2025 0 demerits · 0 violations
Inspector comments: Pool is open for 2025 pool season No night swimming No rope length on paperwork/ cdp mobile Measured the rope on site. The rope is 50 feet long.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 16, 2024 14 demerits · 3 violations
Inspector comments: CPO, Shawn present during the inspection. Verified pumps (fixture and feature) and main drains. Night swimming prohibited. Permit issued.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. pH was tested at 7.0. CDI - CPO corrected to 7.6
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Some debris on the main drains. CDI - CPO cleaned the drain covers.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. No extra basket for filtration pump and feature pump. Provide prior to opening the pool.

View this inspection on the county portal ›

May 10, 2023 0 demerits · 0 violations
Inspector comments: No night swimming allowed

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 1, 2023 0 demerits · 0 violations
Inspector comments: Pool inspected with Shawn. Permit denial. Facility does not have updated PDSC form. Previous form from 2019 stated pool has 4 Aquastar equalizer skimmers and CPO stated they were taken out 3 years ago along with new main drains. Please call the main office at 980-314-1620 to pay revisit fee of $100 and when ready for re-inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 7, 2022 6 demerits · 1 violation
Inspector comments: NO NIGHT SWIMMING.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope > 50’. CDI to 50’.

View this inspection on the county portal ›

Apr 7, 2021 0 demerits · 0 violations
Inspector comments: PDSC verified with 2019 approved forms located on Charmeck.meckpools.org. No violations noted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 9, 2020 0 demerits · 0 violations
Inspector comments: PDSC information verified during inspection. Drain covers were replaced and updated in 2019. Night swimming not permitted at this facility. ** Removed glass located inside firepit near equipment room. Replace glass with another substance such as rocks. Facility understands that although the pool is permitted, it will not open until Mecklenburg County and the State of NC declares it to be safe to do so.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 23, 2019 10 demerits · 2 violations
Inspector comments: PDSC information verified during inspection. Night swimming not permitted at this facility.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed several expired reagents during inspection. CDI: Current reagents tested the same results as EHS test kit during inspection, but PIC ordered new reagents during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 47.5 ft (50 required). CDI: New 50 foot rope obtained and affixed to buoy.

View this inspection on the county portal ›

May 15, 2018 10 demerits · 2 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed depth markers that are 3 inches. Must read 0ft 3in or 1/4ft. Per Tim Dutcher must be corrected before 2019 permit can be issued.
#22 · Premises: emergency telephone provided −6
Observed phone sign behind a tree. Sign relocated where visible.

View this inspection on the county portal ›

May 1, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522 .2537 Decks free of trip hazards; Observed deck chairs within 6 feet of pool edge. CDI chairs moved.

View this inspection on the county portal ›

May 4, 2016 4 demerits · 1 violation
Inspector comments: GC. - Observed location of emergency phone not visible to the entire pool (blocked by tree) CDI- CPO filled in emergency phone location on pool rules that are visible.PDSC pump information did not match. Form must be re-submitted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a foot hold behind the fence (speaker in rock). CDI- Rock was moved.

View this inspection on the county portal ›

Jun 8, 2015 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Provide soap and paper towels at hand washing sink in men and women bathroom. No soap available in both bathrooms. Tightly secure loose toilet paper holder in men bathroom.

View this inspection on the county portal ›

Jun 2, 2014 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 4, 2014 2 demerits · 1 violation
Inspector comments: 16) Observed fence meeting requirements in place. 17) Observed proper deck clearance. 22) Observed emergency phone working with correct signage. 911 has property name as Simpson Housing. Contact phone company to change name to Silos South End Apartments. Permit issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 124°F. Water shall be 110°F or less. Corrected.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SILOS SOUTH END APARTMENTS” or State ID 2060501285). Inspection type (routine vs. follow-up) is not published in the county's data.