‹ Back to search

6demerits

DOUBLETREE CHARLOTTE EXECUTIVE PARK

5624 WESTPARK DRIVE, Charlotte, NC 28217
Seasonal Swimming Pool · NC permit/State ID 2060501287
Latest result6 demerits
Last inspectedMay 6, 2026
Inspections on record12
On record sinceMay 7, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 May 7, 2014: 12Jun 18, 2015: 12Jun 1, 2016: 8Jun 8, 2017: 12May 16, 2018: 8May 8, 2019: 4Jun 30, 2020: 6May 6, 2021: 4Jun 14, 2022: 4May 12, 2023: 8Jul 17, 2025: 12May 6, 2026: 6
May 7, 2014Lower is betterMay 6, 2026

Inspections & violations

May 6, 2026 6 demerits · 2 violations
Inspector comments: Inspection conducted with CPO Tommy Rivera present. CPO # is C-183721. PDSC forms and the following permit restrictions verified: Pool flow must be at least 99 gpm for turnover and cannot exceed 106 gpm for filter limitation. Flow meter must remain operational. Pre-2010 fence. Fence has gaps greater than 2” under but does not exceed 4”. Night swimming not permitted. CPO advised that the pool will not be operating after dusk for 2026 season. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris inside skimmers.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water on pump room floor originating from slow leak at ceiling pipes.

View this inspection on the county portal ›

Jul 17, 2025 12 demerits · 3 violations
Inspector comments: Pre-2010 fence. Fence has haps greater than 2" under but does not exceed 4" Permit Restriction: Pool flow must be at least 99gpm for turnover and cannot exceed 106gpm for filter limitation. Flow meter must remain operational. Infield Plan Review complete and approved Pump Flow - 101gpm Pump - Hayward W3SP3206VSP Main Drain - Aquastar 1216xxx 2017 Skimmer - 2" Main Drain - 2" Return - 2.5" (differs from form) Returns - 11 (differs from form) Skimmers - 3 Filter - Pentair TR140
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy not USCG approved. Replaced during inspection. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed chairs within 6 feet. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No chemical storage room .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.

View this inspection on the county portal ›

May 12, 2023 8 demerits · 2 violations
Inspector comments: Inspection completed with Kevin Burke present. Notes: Observed one area of damaged coping at pool edge. Repair. Equalizer coverings expire in February, 2024. Ensure they are replaced prior to this date to prevent permit suspension. CPO overseeing property is Shakeen Hough. CPO # is 15658055.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum cap not installed. CDI- cap was installed; there was no suction at time of inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool. CDI- furniture relocated.

View this inspection on the county portal ›

Jun 14, 2022 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor and around the walls. Clean. .2537(14) Keep pool surface and pool floor free of debris.

View this inspection on the county portal ›

May 6, 2021 4 demerits · 1 violation
Inspector comments: Pool has twin dolphin tiles in dark blue in center of pool. Per pool operator, this tile has been in the pool since construction in 1987. EHS advised pool operator that next deck construction project shall include replacement of these tiles in exchange for lighter colored tiles to ensure complete bottom of the pool can be observed at all times.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed one inch goffset n deck near ladder closest to pump room.

View this inspection on the county portal ›

Jun 30, 2020 6 demerits · 2 violations
Inspector comments: Inspection completed with Ken “issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.Observed skimmers with debris.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed pipes in pump room not fully labeled to show water flow.

View this inspection on the county portal ›

May 8, 2019 4 demerits · 2 violations
Inspector comments: PDSC information verified.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on floor of pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap on backwash discharge.

View this inspection on the county portal ›

May 16, 2018 8 demerits · 3 violations
Inspector comments: Night swimming verification visit required. Pool hours are from 10a - 10p. Night swimming is not permitted until EHS makes another visit to verify sufficient lighting.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not working. CDI: repaired by operator and now working properly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on pump room floor. Clean
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Re-label pipes in pump room.

View this inspection on the county portal ›

Jun 8, 2017 12 demerits · 4 violations
Inspector comments: Observed cleaning needed inside pump room. Observed lots of broken equipment from hotel and leaves throughout pump room. *Post permit where visible to pool users. Observed permit kept in record book inside pump room.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed build-up on tiles of pool wall. Clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmer baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one endcap missing from ladder on hotel side. Replace.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label some parts of pipes including backwash line in pump room.

View this inspection on the county portal ›

Jun 1, 2016 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris at bottom of pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed floating debris inside skimmer baskets. Cleaned on site.

View this inspection on the county portal ›

Jun 18, 2015 12 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily record checklist to not include drain covers. Facility must check and record drain cover compliance daily.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing. All weirs must be in place and functioning.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing footing end cap. Ladder must be in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross ventilation in pump room. Provide forced cross ventilation in pump room. Observed emergency phone working, however EHS was unable to hear operator well. Make phone louder.

View this inspection on the county portal ›

May 7, 2014 12 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed approx 3 tiles missing on color band on stairs. Replace.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed left ladder end cap missing- left side of pool. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Maintain body hook secured. Observed not secured, only using the plastic pin. Secured during inspection with bolt and nut.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “DOUBLETREE CHARLOTTE EXECUTIVE PARK” or State ID 2060501287). Inspection type (routine vs. follow-up) is not published in the county's data.