Apr 24, 2026 14 demerits · 3 violations
Inspector comments: NOTE:
- No Night Swimming permitted.
- CPO: Marion Smith present during permit inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.- Observed 3 missing weirs, replaced 2 out of 3 at the time of inspection. Ensure to have all weirs in placed.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.- Observed 3 missing return outlet covers. The covers replaced during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Observed loose screws securing the hook and pole tight. Item fixed at the time of inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.- Observed the rope length is too long, item fixed to be at 41ft at the time of inspection.
Apr 22, 2025 8 demerits · 2 violations
Inspector comments: No night swimming . Walked with Douglas. Markings on pump are missing. PER Chris S motor matches HP so pump is good . It’s Pentair Whisperflo WFE12 THP is 3.45 No permit restrictions
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate leading to pool was not self latching. CDI.. Maintenance repaired gate while EHS was completing inspection.
May 1, 2024 10 demerits · 2 violations
Inspector comments: Night swimming not approved.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed skimmers with debris inside. CDI- CPO cleaned skimmers.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed buoy throw rope to be 42ft. CDI- CPO provided rope at 41ft.
May 19, 2023 0 demerits · 0 violations
Inspector comments: No violation observed today
No violations were recorded for this inspection.
May 16, 2023 16 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool water ph at 8.2
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed offsets around 5 decorative skinner covers.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed two numbers posted on emergency phone. EHS called both numbers and emergency phone did not ring back.
Apr 19, 2022 8 demerits · 2 violations
Inspector comments: .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate not self closing and latching. CDI- Gate fixed during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers full of debris. Clean skimmers
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. Get fixed.
Apr 12, 2021 18 demerits · 6 violations
Inspector comments: Remove the "dial 911" instructions; call box is a "push button"
#5 · Water quality: daily written records of water quality and test kit kept on site −4
cyanuric acid & total alkalinity levels to be recorded 1 x week-corrected during inspection; record main drain checks daily
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
replaced missing weirs during inspection
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
two handrails are loose and need to be tightened down
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
flow meter not working-corrected during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
light bulb in chemical room needs to be replaced; keep chemicals off the floor
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
shower pull string needs to be corrected so shower will turn off; mirrors to be of shatterproof construction; urinal in men's restroom needs to be repaired
May 21, 2020 8 demerits · 3 violations
Inspector comments: No night swimming permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 3 missing weirs. CDI, weirs installed while on-site.
.2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 2 loose handrails.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Observed light not working in chemical storage room.
May 14, 2019 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed flooring in pump room wet in need of removal.
May 15, 2018 10 demerits · 3 violations
Inspector comments: PDSC information updated, approved and verified. Facility does not want night swiming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. - Observed one missing weir; CDI (corrected during inspection) the weir was replaced.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. - Observed one chair 4 ft from the edge of the pool and 2 chairs 5ft from the edge. CDI - chairs were moved to correct locations.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. - Mirrors in the restrooms are not shatterproof.
Apr 17, 2017 12 demerits · 4 violations
Inspector comments: Pool passed pre-inspection - pending update of Pool Drain Safety Compliance form
15. Trim/remove bushes to make safety equipment more visible and accessible
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Information for 3rd main drain needs to be added to VGB form, equalizer cover information needs to be corrected
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder assembly needs to be secured, pavers around ladder need to be secured
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors should be shatterproof
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Floors should be slip-resistant
Jul 6, 2016 10 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed no weirs in place at start of inspection. CDI- CPO provided and started installing during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed all ladders and handrails to be loose. Repair.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no "Shower before entering pool" sign present. Provide.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in men's and women's restroom are not shatter resistant. Provide.
Apr 14, 2015 14 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook bolts fastened to inside of body hook which is a safety hazard. Corrected, PO turned bolts to outside of body hook.
#22 · Premises: emergency telephone provided −6
Pool phone had no power, was not working. Corrected, PO returned power to phone, observed phone properly working.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restroom mirrors need to be shatterproof.General Comment: Permit to be issued.