2demerits

MAA FIFTY-ONE

1301 CRESCENT LANE, Matthews, NC 28105
Seasonal Swimming Pool · NC permit/State ID 2060501316
Latest result2 demerits
Last inspectedMay 14, 2026
Inspections on record12
On record sinceMay 4, 2015

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 May 4, 2015: 12Apr 19, 2016: 6Jun 17, 2017: 4Apr 19, 2018: 6May 24, 2019: 18May 11, 2020: 0Apr 28, 2021: 6Apr 29, 2022: 16Jun 1, 2023: 8May 16, 2024: 10Apr 29, 2025: 22May 14, 2026: 2
May 4, 2015Lower is betterMay 14, 2026

Inspections & violations

May 14, 2026 2 demerits · 1 violation
Inspector comments: No night swimming. Requires repair to flow meter 2026 - flow meter does not read up to max value of the drain cover and pump exceeds the drain covers. Permit Restriction: Flow meter must remain operable. Flow required at 112 gpm to 120 gpm to mee turnover and flow restriction of the flow meter installed. Flow greater than 150 gpm exceeds the main drains.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed end caps missing on ladders.

View this inspection on the county portal ›

Apr 29, 2025 22 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Oscar Lahoz. PDSC information and permit restrictions verified onsite: Observed operable flow meter with flow registering at 112 GPM. Additional observation: No spare pump basket available. CPO unable to procure locally and has placed online order which is expected to arrive by Thursday 5/1/25. Verification visit required. No night swimming permitted. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Repair loose skimmer lid between 3 1/2 and 4 ft depth markers. CDI by instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed loose handrail at 4 1/2 depth marker.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope exceeding 38”. CDI - Corrected by shortening to required length.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(3) There shall be no loose coping. Observed a couple of deck pavers wobble when walked on, relevel or add/remove sand so they dont shift when walked on. CDI - CPO filled areas with sand.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. No spare pump basket provided. CPO ordered item online and ETA is 5/1/25.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed bags of bicarbonate stored directly on the floor in the pump room. CDI - CPO removed chemicals from floor.

View this inspection on the county portal ›

May 16, 2024 10 demerits · 3 violations
Inspector comments: everything verified in the field
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
fix skimmer lid and one weir
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
fix bumper on ladder
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
fix eye ball inside pool

View this inspection on the county portal ›

Jun 1, 2023 8 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed screws removed from 3 windows in gym, presumably by residents. Check that screws remain in place. CDI-screws replaced
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(3) There shall be no loose coping. Observed a couple of deck pavers wobble when walked on, relevel or add/remove sand so don’t shift when walked on.

View this inspection on the county portal ›

Apr 29, 2022 16 demerits · 5 violations
Inspector comments: Night swimming not permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 missing weirs. CDI, weirs installed during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 wall eyeball fittings missing from pool wall. CDI, fittings installed during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed 1 door leading to pool deck from office not self-latching. CDI, operator repaired latch on-site.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed pipes not labeled in equipment room and flow not identified. CDI, operator labeled flow on piping.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Observed hose bib missing back flow prevention device.

View this inspection on the county portal ›

Apr 28, 2021 6 demerits · 2 violations
Inspector comments: Kings 3 issues was corrected
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean out skimmer baskets
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Fix shower knob

View this inspection on the county portal ›

May 11, 2020 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 24, 2019 18 demerits · 4 violations
Inspector comments: No night swimming. Pool will close by dark each night.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. One bumper missing on bottom of ladder. Replace
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope measuring over 1.5 times the width of the pool. CDI - Cut to 38ft.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Posted call back number is incorrect. CDI - Corrected during the inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter stuck. CDI - Corrected by maintenance.

View this inspection on the county portal ›

Apr 19, 2018 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris (leaves) on pool floor. CDI- started cleaning pool during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder in 4ft missing endcap on bottom. Replace.

View this inspection on the county portal ›

Jun 17, 2017 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed electro magnetic fences not self latching due to programming new key fobs. Gates must remain closed until operating properly(self-clsoing and self-latching).

View this inspection on the county portal ›

Apr 19, 2016 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
Observed 7.1pH today. BiCarb added and corrected to maintain at 7.3.

View this inspection on the county portal ›

May 4, 2015 12 demerits · 4 violations
Inspector comments: #15 Turn screws on body hook to prevent injury.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Provide extra hair lent basket for pump.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Ensure that flow meter is functioning properly (Stuck)
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical should be stored separate from pump room clean excess debris from pump room. Pump room does not have unobstructed walk area.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Floors in restroom are not slip resistant.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MAA FIFTY-ONE” or State ID 2060501316). Inspection type (routine vs. follow-up) is not published in the county's data.