‹ Back to search

8demerits

MAA CITY GRAND

608 MCCULLOUGH DR, Charlotte, NC 28262
Seasonal Swimming Pool · NC permit/State ID 2060501317
Latest result8 demerits
Last inspectedMay 1, 2026
Inspections on record13
On record sinceMay 7, 2015

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 May 7, 2015: 4Apr 27, 2016: 4May 22, 2017: 20May 24, 2018: 6May 23, 2019: 8May 20, 2020: 0Apr 23, 2021: 4Apr 20, 2022: 14Apr 25, 2023: 18May 12, 2023: 4May 8, 2024: 8Apr 15, 2025: 6May 1, 2026: 8
May 7, 2015Lower is betterMay 1, 2026

Inspections & violations

May 1, 2026 8 demerits · 2 violations
Inspector comments: Permit Restriction: Flow meter shall remain operable. Flow shall not exceed 150 gpm due to drain cover flow restriction. Suction Hazard. The 5% flow meter was observed to be properly installed during the inspection. NIGHT SWIMMING NOT PERMITTED.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0, corrected during inspection to 7.2
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed both white pool ladder bumps missing to ladder near 5 foot depth marker.

View this inspection on the county portal ›

Apr 15, 2025 6 demerits · 2 violations
Inspector comments: Flow meter shall remain operable. Flow shall not exceed 150 GPM due to drain cove flow restriction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Observed rubber caps missing on the ladder.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. - Flow meeting gauge was stuck but fixed during the inspection

View this inspection on the county portal ›

May 8, 2024 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers containing large amounts of debris. CDI - CPO cleaned skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed mulch holding the fence from self. Closing. CDI. PIC removed and fence able to self close.

View this inspection on the county portal ›

May 12, 2023 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor in need of cleaning. Operator is in the process of cleaning pool.

View this inspection on the county portal ›

Apr 25, 2023 18 demerits · 4 violations
Inspector comments: NOTE: .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length too short at 45ft. New rope put on at 50ft.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 75% of weirs missing.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed less than 6ft of clearance around pool. Move furniture so that 6ft of clearance is around pool.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed 9-11 with the wrong address on file. Get changed.

View this inspection on the county portal ›

Apr 20, 2022 14 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH of the pool at 7.0. CDI - CPO raised pH to a 7.2.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers containing large amounts of debris. CDI - CPO cleaned skimmers.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs within 3.5 ft of the pool. CDI - Chairs were moved back to provide 6ft of clear walking space around the pool.

View this inspection on the county portal ›

Apr 23, 2021 4 demerits · 1 violation
Inspector comments: 22. 2530(f) Observed wrong number posted at the emergency phone. New number for the phone was posted and was operable.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. Keep flow meter operable

View this inspection on the county portal ›

May 20, 2020 0 demerits · 0 violations
Inspector comments: No violations noted. Gate with gaps >4 inches covered completely by chicken wire. When ordering new gate it must meet all the rules in .2528.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 23, 2019 8 demerits · 2 violations
Inspector comments: This pool is not permitted for night swimming. PDSC was resubmitted and approved.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. observed end caps missing on pool ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. observed ring buoy rope 53'. CDI to 50'

View this inspection on the county portal ›

May 24, 2018 6 demerits · 3 violations
Inspector comments: 15. Relocate safety equipment or move chairs to make easier access in case of emergency
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Remark valves & pipes
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatter-resistant construction
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow preventer required on hose bib; fill spot should not extend >2" from edge of pool

View this inspection on the county portal ›

May 22, 2017 20 demerits · 5 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily main drain or equalizer cover checks and observed no weekly CA or TA checks on daily records forms. Corrected, PO added column to document daily drain cover checks and will check CA/ TA at least once a week.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one weir missing, corrected, PO installed weir.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
pool ladder missing protective end caps at wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed one bolt in body hook and bolt facing inside of hook as a safety risk. Corrected, PO installed to bolts facing outside of hook.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pool gate near excersise wing of clubhouse is not auto closing/ latching. Corrected, PO increased tension to gate to properly close/ latch.

View this inspection on the county portal ›

Apr 27, 2016 4 demerits · 1 violation
Inspector comments: Seon Clark was present during the inspection.***Pool permit will be available at http://Meckpools.charmeck.org in 3 business days.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets were dirty, and one weir was not secure. CDI - weir was repaired and baskets were cleaned.

View this inspection on the county portal ›

May 7, 2015 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518 .2537 Surface skimmers; weirs. Keep wiers installed in surface skimmers; Observed 3 skimmers missing weirs; CDI new weirs installed.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MAA CITY GRAND” or State ID 2060501317). Inspection type (routine vs. follow-up) is not published in the county's data.