10demerits
MAA LEGACY PARK
8810 LEGACY PARK DRIVE, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060501326
Latest result10 demerits
Last inspectedApr 1, 2026
Inspections on record13
On record sinceMay 13, 2015
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 13, 2015Lower is betterApr 1, 2026
Inspections & violations
Apr 1, 2026 10 demerits · 2 violations
Inspector comments: Pump set to 3110 RPM per permit restriction. No night swimming permitted at pool.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 7.0 at beginning of inspection. Pool operator added sodium bicarbonate and pH checked again at end of inspection and it measured 7.2.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Weir missing. Replace missing weir.
Apr 23, 2025 14 demerits · 4 violations
Inspector comments: EHS walked with Demorris, Pump was set at 3110rpm per restrictions.No night swimming. Body hook had shank facing inside and head facing outside. EHS had CPO to switch to were the shank is facing outside and head facing inside of body hook. Demorris Lyons is new CPO verified per restrictions.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers full of debris
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladders without stoppers. CPO has stoppers , showed EHS , just needs to install them.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length for ring buoy was less than required 39 inches(37 inches). CPO went and bought new rope while EHS waited. Rope was replaced meet 39 inches
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemicals stored on the floor.
May 20, 2024 12 demerits · 3 violations
Inspector comments: Night swimming not approved.
EHS field verified information to be correct.
Pump Pentair Intelliflo VSF 011056, pump must be set at 3110rpm (speed 3 by default).
Main Drain Aquastar 1216xxx (vgb2017)
Equalizers Disabled
Filter Pentair TR140C
Returns 8 total
Pipping all 3” return, skimmer and main drain
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed minor debris in skimmers. CDI- CPO cleaned skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Observed step ladders without rubber bumpers installed. CDI- CPO installed bumpers.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Observed pool phone number posted to be incorrect. CDI- CPO posted correct number. EHS able to connect to 911 services and verify information posted to be correct. EHS able to call phone via phone number posted.
May 9, 2024 18 demerits · 4 violations
Inspector comments: Night swimming not approved. Re inspection fee is required prior to permit being issued. Please contact the main office at 980-314-1620.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - EHS observed equalizers NOT disabled per state recommendations as documented on PDSC form. -Permit Denial Item-
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmers. CDI- CPO cleaned skimmer baskets.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. - Observed ladder stoppers absent.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Observed emergency phone number provided not the same as 911 documented number. When number provided by 911 is called phone does not answer. Automated kings III recording plays over and over. - Permit Denial Item-
Apr 24, 2023 2 demerits · 1 violation
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping direction not labeled. Pool operator labeled pipes.
Jun 8, 2022 6 demerits · 2 violations
Inspector comments: EHS did not verify GMP for flow rating. No permit restrictions on pool packet.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer in need of cleaning on side closest to the club door.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed directional flow arrows needed on piping.
Apr 29, 2021 0 demerits · 0 violations
Inspector comments: No violations. All 4 and 6 point demerit items in compliance.
No night swimming.
No violations were recorded for this inspection.
Apr 23, 2020 12 demerits · 4 violations
Inspector comments: Justin Clowers present during the inspection. No signature due to COVID-19 restrictions.
Permit issued for no night swimming. Pool to remain closed to public until order restictions are lifted.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
Could not verify ASSE1013 due to deterioration of placard. Mirrors could not be verified as shatterproof.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail at steps a bit loose. Keep in good repair. Ladders >6" from pool wall from ladder rung. Maintain 3" to 6" from ladder rung to wall. No end caps on one ladder. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall provides foothold on fence near gate entry. Measures 28" to magnetic locking mechanism. Part of pool barrier. Barrier built pre-2010. All other issues with latching mechanism heights repaired from previous site visit. Back gates permanently disabled.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some damage around ladder handrails on deck. Keep decking in good repair. Not greater than 1/2" offsets. Continue to monitor.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor in pump room wet from check valve leaking. Repair leak and keep floor dry.
May 8, 2019 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets full of debris in need of cleaning.
May 10, 2018 6 demerits · 2 violations
Inspector comments: PDSC information verified and correct. Facility does not want night swimming.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. - Observed the gate by the soda machine bouncing back open after the gate slams. CDI (corrected during inspection) the gate was adjust to self-latch.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. - Mirrors in the restrooms are not shatterproof.
May 19, 2017 12 demerits · 3 violations
Inspector comments: Pool passed pre-inspection pending approval of the revised PDSC forms (new pump has been installed)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record main drain check daily
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Information in database does not match field observation, equalizer covers 6HP vs 4HP
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatterproof construction
Jun 16, 2016 14 demerits · 4 violations
Inspector comments: 22.) Observed phone number listed as an emergency call back located on emergency telephone information was incorrect. CDI- Incorrect phone number was taped over and correct number provided.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed cyanuric acid check not documented since 5/31/16 and no main drain, chlorine or pH checks documented since 6/3/16. Intent to Suspend issued. Maintain log of main drain checks, pH and chlorine daily. Maintain cyanuric acid check logs weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder rail to be very loose and bottom caps missing from both ladders. CPO stated people take them off and play with them, CPO was able to locate caps for 1 ladder but not the second one. Repair or replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy rope to be 36 ft. Rope length needed- 39 Ft. CDI- Apartment manager provided new rope measuring the correct length.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in both restrooms are not shatter resistant. Provide.
May 13, 2015 6 demerits · 2 violations
Inspector comments: 15) Recommend replacing ring buoy.Go online to Meckpools.charmeck.org to print permit and post a copy in pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets with sprouting seeds. Clean regularly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan being replaced in pump room. Provide good air flow in pump room.