10demerits
ELIZABETH STATION
2512 WEDDINGTON AVE, Charlotte, NC 28204
Seasonal Swimming Pool · NC permit/State ID 2060501332
Latest result10 demerits
Last inspectedMay 8, 2026
Inspections on record13
On record sinceJun 8, 2015
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 8, 2015Lower is betterMay 8, 2026
Inspections & violations
May 8, 2026 10 demerits · 3 violations
Inspector comments: PERMIT ISSUED
POOL IS NOT PERMITTED FOR NIGHT SWIMMING.
FLOW METER MEASUREMENT: 110 GPM
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets full of debris. CDI: CPO emptied skimmer baskets.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed ADA uninstalled at pool deck and metal pipe used to secure ADA chair sticking out above deck more than 1/2” creating a trip hazard. CDI: Chair re-installed by CPO and no longer a trip hazard from piping.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Observed chemicals for pool being stored in pump room. Chemical room is provided but being used for storage of other items. Store chemicals in separate room for chemical storage.
May 21, 2025 8 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Carl Williams and Colleen Somoles present. PDSC information verified. No existing permit restrictions.
Permit issued. Pool is not permitted for night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed prime valve plumbing line leaking during backwash. CDI - CPO repaired the leak.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2625(j) Soap dispensers with either liquid or powdered soap shall be provided at each lavatory or required shower. Observed no soap available in men’s restroom. CDI - Soap provided.
May 22, 2024 10 demerits · 2 violations
Inspector comments: No Night swimming.
Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. Observed plug in line to the pump in one of the skimmers. CDI: Plug removed during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy with ropes around buoy disintegrating. CDI: New buoy provided during inspection.
Jun 1, 2023 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed rope for ring buoy to be greater than 50ft. - CDI - CPO corrected rope length to 50ft while EHS present.
May 26, 2023 14 demerits · 3 violations
Inspector comments: Verified pumps, main drains (filtration and features), and equalizers.
Night swimming not permitted.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed some of the testing agents have expired or going to expire this month. Replace.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no column to check the main drains. Provide this and check daily.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed the ring buoy rope more than 50’, CDI- CPO cut the rope down to 50’
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
Both gates (opening to 7th street and to the stairwell) not self latching. One gate was fixed but gate to the stairwell was still not self latching. Permit denial issued. Contact the department at 980-314-1620 to request a reinspection and pay $100 reinspection fee.
May 3, 2022 10 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING PERMITTED.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
No rope for ring buoy present, CDI- PIC obtained rope for 50 feet
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.
Gates were not self closing. CDI- PIC adjusted springs and used WD40 and gates were self closing and latching.
Apr 13, 2021 0 demerits · 0 violations
Inspector comments: Distance from foothold to top of gate is >45 inches.
No violations were recorded for this inspection.
May 7, 2020 4 demerits · 1 violation
Inspector comments: “Due to COVid19 and public health responsibility, safe distancing and minimizing point of contact, inspection will not be signed as agreement"
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs in one spot within 6 ft of pool edge. CDI
Jun 6, 2019 0 demerits · 0 violations
Inspector comments: Night swimming is not permitted at this facility until a night visit is made by the EHS to determine if lighting is sufficient.
CPO was present during time of the inspection.
Noted hyrdostat relief valve between main drains with hayward cover.
No violations were recorded for this inspection.
Apr 12, 2018 6 demerits · 2 violations
Inspector comments: No night swimming until lights have been checked by Health Department.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One basket was full of debris. Clean baskets daily. Corrected During Inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bags of Polymeric sand on ground (paper). Keep any chemicals stored in paper bags off ground.
Mar 29, 2017 2 demerits · 1 violation
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Pool shower turned off at time of inspection. Function restored by maintenance staff.
Apr 15, 2016 0 demerits · 0 violations
No violations were recorded for this inspection.
Jun 8, 2015 18 demerits · 4 violations
Inspector comments: Immediate Suspension issued for pH. Once corrected, and acid lowered, contact Katie at 704-309-5494 to re-open pool.
#3 · Water quality: pool water pH −6
Pool pH at 7.0. Maintain at 7.2 to 7.8. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid >100 ppm. Acid level will affect pH. Lower acid to below 100 ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
4 skimmers without. weirs. Replace weirs where needed.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Pool furniture 3 ft to pool. Maintain 6 ft clearance all the way around the pool.