4demerits
CAMDEN SOUTHLINE
2300 SOUTH BLVD, Charlotte, NC 28203
Seasonal Swimming Pool · NC permit/State ID 2060501342
Latest result4 demerits
Last inspectedApr 10, 2026
Inspections on record13
On record sinceAug 7, 2015
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Aug 7, 2015Lower is betterApr 10, 2026
Inspections & violations
Apr 10, 2026 4 demerits · 1 violation
Inspector comments: Permit Issued.
POOL IS NOT PERMITTED FOR NIGHT SWIMMING.
Flow meter measurement: 120 GPM
Observed all 5 equalizers covers matching what is documented in PDSC form.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets with debris. CDI: CPO cleaned out baskets of skimmers during inspection.
Apr 1, 2026 6 demerits · 1 violation
Inspector comments: Permit Denied due to equalizer covers not matching PDSC form.
Flow meter reading: 120 GPM
Night swimming is not permitted.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
Vaccum suction outlet cap was not secured shut. CDI - Secured shut during inspection. REPEAT
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed five Aquastar 6HPHA 2008 equalizer covers with light blue dot installed. PDSC stated that the cover installed are five Aquastar 6HPHA 2017. Permit denied.
Apr 1, 2025 12 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
PH recorded at 7.0 CDI - Soda ash added to pool in raise level to 7.2
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
Vaccum suction outlet cap was not secured shut. CDI - Secured shut during inspection.
Apr 15, 2024 0 demerits · 0 violations
Inspector comments: CPO, Danone; Willner present
Verified pump, main drains and equalizers.
Night swimming prohibited.
Permit issued.
No violations were recorded for this inspection.
May 18, 2023 0 demerits · 0 violations
No violations were recorded for this inspection.
May 3, 2022 6 demerits · 1 violation
Inspector comments: Electrical permit number: E4192178
NIGHT SWIMMING NOT PERMITTED.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Rope was less than required amount, CDI- More rope added.
Apr 7, 2021 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
emergency call box was not functioning properly, repaired during visit.
Apr 22, 2020 4 demerits · 1 violation
Inspector comments: “Due to COVid19 and public health responsibility, safe distancing and minimizing point of contact, inspection will not be signed."
Equalizer covers scheduled for repalcement in July replaced today and new PDSC to be completed with C. Sells.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed only slight debris in pool.
.2537(14) Keep pool surface and pool floor free of debris.
Apr 10, 2019 0 demerits · 0 violations
Inspector comments: No non-critical items found.
Facility does not have night swimming.
No violations were recorded for this inspection.
Apr 4, 2018 2 demerits · 1 violation
Inspector comments: Hours of pool are Dawn to Dusk. Backup battery for Gate FOB's should remain functional.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No extra pump basket.
Apr 5, 2017 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535 Daily written records; Observed main drain check missing from daily records. CDI MD check added to daily record sheet.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518, .2537 Skimmer systems clean; Observed debris in need of removal in skimmer baskets.
Apr 28, 2016 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
Correct phone number on sign
Aug 7, 2015 12 demerits · 2 violations
Inspector comments: Permit will be issued online at Meckpools.charmeck.org within 3 business days. Print permit and place a copy in the pool area.
#2 · Water quality: disinfectant residual provided by −6
Cl 0.2 ppm. Maintain at least 1ppm. Corrected to 1ppm by operator.
#22 · Premises: emergency telephone provided −6
Phone number did not match number 911 had. Corrected by operator.