6demerits
MAA BALLANTYNE
15105 ARBOR TRAIL CT, Charlotte, NC 28277
Seasonal Swimming Pool · NC permit/State ID 2060501348
Latest result6 demerits
Last inspectedApr 2, 2026
Inspections on record13
On record sinceMay 17, 2017
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 17, 2017Lower is betterApr 2, 2026
Inspections & violations
Apr 2, 2026 6 demerits · 1 violation
Inspector comments: New flow meter installed and verified. FlowVis Serial No. F01C143092.
Permit Restriction: Flow meter must remain operable. Flow shall not exceed 320 GPM due to drain cover flow restriction. Suction Hazard.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope longer than 50ft. Rope cut to 50ft.
Apr 25, 2025 14 demerits · 3 violations
Inspector comments: Inspection completed with Faustino Cabral.
Flow meter operable.
No Night swimming permitted.
Flow cannot exceed 320 GPM.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Observed fitting for light fixture not flush, slightly protruding from wall and in need of repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair.
Observed area of deck with large amount of grout missing.
CPO will provide picture evidence of repaired deck.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Observed phone number at kings III phone not legible.
CDI - CPO made number visible.
May 20, 2024 10 demerits · 2 violations
Inspector comments: flow meter was operable per permit conditions
Inspection conducted with Faustino Cabral
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
Observed 911 dispatch did not have correct phone number and address for the location. CDI phone number changed on pool side and third party contacted to update address. Called dispatch again and proper information verified.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump baskets.
May 9, 2024 12 demerits · 3 violations
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
Observed Kings III phone that had operator to connect to 911, but 911 does not have same address and phone number for pool. 911 has pool at 14185 Ballantyne Village Way and phone number as 661.701.9628 which does not match what’s listed on board or in Kings III records.
Unable to use number to call 911. Kings III was able to allow phone calls to come through to box at pool deck.
Permit denied until remaining issue repaired.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair.
Observed pump in equipment room that was a Pentair EQ500 but PDSC form states it is a Pentair CH-50. PIC stated it was changed a year ago. Updated PDSC form needs to be submitted for approval.
Permit denied until issues resolved.
.2518(e) Provide a spare basket for pump. Observed no spare pump basket
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair.
Observed restrooms in need of cleaning.
Apr 18, 2023 16 demerits · 5 violations
Inspector comments: Pool not permitted for night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed one damaged tile on pool wall that must be repaired before the pool supply.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed lighting outside of wall enclosure. Repaired onsite by pool operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed trip hazard on the deck with gaps present.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed one dry chemical bag inside plastic bag on floor. Keep in waterproof containers. Pump room baseboard flooring area observed damaged.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Observed hose bib without under shower area without backflow prevention device attached.
Apr 20, 2022 4 demerits · 2 violations
Inspector comments: Pool operator stated visitors to pool are expected to use restroom at their apartment. Plumbing repair underway to pool restrooms today. Pool will be voluntarily closed while under repair per pool operator Victor Espinal. No night swimming requested.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed loose ladder on the left side of pool at the 4ft depth marker. Tighten. -2-
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed one dry chemical bag stored partly on floor and partly inside plastic bag on floor. Keep in waterproof container off floor. -2-
May 5, 2021 0 demerits · 0 violations
Inspector comments: No demerits taken.
No violations were recorded for this inspection.
May 19, 2020 10 demerits · 3 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Daily record sheet does not include drain check column. CDI- sent form with drain check column for use.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Ladder attached to inlaid brick in deck. Brick with ladder attached is loose, ladder wobbles when used.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Sheetrock partition in pump room heavily damaged from moisture.
May 24, 2019 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved filter in good repair. Observed invoice for replacement parts for filters. CPO demonstrated backwashing can be completed.
May 3, 2018 8 demerits · 2 violations
Inspector comments: Observed wall in pump room starting to corrode and disintegrate. Make sure to fix to ensure area will be a dry, well-ventilated area.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed one cracked depth marker tile. Lettering still visible. Make sure to repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed cracks around pool deck greater than .5 inch. CDI Pool operator provided sealant to close cracks around pool.
May 26, 2017 0 demerits · 0 violations
Inspector comments: Pool opened from 9 am - 10 pm
Observed lighting in pool and surrounding the deck area.
Pool permit shall be posted visible to the pool deck at all times.
Ensure that when corrections are addressed when they are needed on the records sheets to demonstrate an action being taken.
Ensure pool remains closed until permit is received.
No violations were recorded for this inspection.
May 17, 2017 0 demerits · 0 violations
Inspector comments: Permit is denied due to 1. 3 out of 6 weirs missing. Flow meter not in good working condition and PDSC forms incorrect.
It appears that pool has 2 waterway covers not 2 aqua star covers. Pump also states Pentair 011656 CH-50 5 HP. Please correct information and resubmit.
Contact the main office at 980-314-1620 to make payment for return visit.
No violations were recorded for this inspection.
May 17, 2017 0 demerits · 0 violations
Inspector comments: Establishment changed to A to change to Q.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MAA BALLANTYNE” or State ID 2060501348). Inspection type (routine vs. follow-up) is not published in the county's data.