Score history

0816 May 27, 2016: 12Jun 26, 2017: 4May 24, 2018: 8Apr 30, 2019: 0Apr 22, 2020: 6May 5, 2021: 8May 12, 2022: 16May 31, 2022: 16Jun 2, 2023: 16May 13, 2024: 10May 20, 2025: 12May 19, 2026: 6May 26, 2026: 0
May 27, 2016Lower is betterMay 26, 2026

Inspections & violations

May 26, 2026 0 demerits · 0 violations
Inspector comments: No violations were observed during the inspection. Night swimming is not permitted

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 19, 2026 6 demerits · 1 violation
Inspector comments: Permit denied due to pH not being within range. Must contact local health department to schedule another inspection and pay fee.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. - pH is below 6.8

View this inspection on the county portal ›

May 20, 2025 12 demerits · 4 violations
Inspector comments: Pool inspection was conducted with Omar Hernandez, CPO. Pool is not permitted for night swimming. Pool hours will be from 10 am til dusk. 50 GPM Pool was built without equalizers.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed area of pool floor that needs to be cleaned or repaired. Area is on back side of pool near ladder.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Tighten ladder located on back side of pool. CDI.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed area near back side edge of pool with a trip hazard greater than 1 inch. Observed area at front of pool with a trip hazard greater than 1/2 inch. CPO will adjust areas.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed that there is not 3 feet of walking space in pump room.

View this inspection on the county portal ›

May 13, 2024 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 6.9 at beginning of inspection. CDI - Operator increased pH to 7.2 by end of inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmer baskets. Clean baskets.

View this inspection on the county portal ›

Jun 2, 2023 16 demerits · 4 violations
Inspector comments: Inspection conducted with CPOs William Oliver and Pedro Noble. PDSC information and restrictions verified. All non-compliant items corrected onsite with exception of 1 of 2 skimmer’s missing its weir. Not approved for night swimming. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 of 2 skimmers missing their weirs. -4-
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed loose hand rail at 3 ft. -2-
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
REPEAT: .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope to be in excess of 1.5 times the width of the pool. CDI - Buoy rope was shortened to the required length of 24 ft. -6-
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed four pool lounge chairs providing < 6 ft of clear walking space around the pool. -4-

View this inspection on the county portal ›

May 31, 2022 16 demerits · 3 violations
Inspector comments: SEE INSPECTION CONDUCTED BY J. WRIGHT 5/12/22 WHICH SHOULD HAVE BEEN A STATUS. ADDED TO CORRECT CDP STATUS.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
#22 · Premises: emergency telephone provided −6

View this inspection on the county portal ›

May 12, 2022 16 demerits · 3 violations
Inspector comments: All violations were corrected during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed buoy rope to be in excess of 1.5 times the width of the pool. CDI - Buoy rope was shortened to the required 24ft length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed two access gates to pool deck not self latching. CDI - Pool operator was able to repair self latching locks during inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed ground level door to pool deck not self latching and without audible alarm. Pool operator stated that pool door is left unlocked and unlatched during apartment building office hours. CDI - Pool Operator was able to repair door so that it is now self latching. Pool operator was informed that door shall remain self latching at all times or use an audible alarm.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency call box was not operating a start of inspection. CDI - Pool operator placed call to Kings III customer service and was told to contact phone company. Phone company was able to restore service during inspection. Kings III call box was able to contact emergency services.

View this inspection on the county portal ›

May 5, 2021 8 demerits · 2 violations
Inspector comments: No night swimming permitted. 70 GPM 11. Tighten hand rail located near stairs of pool. *Issuance of permit by this Department does not negate meeting requirements of Executive Order 195 or seubsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Chemicals in test kit have expired. PIC will provide more up-to-date chemicals.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Skimmer that is located closest to the clubhouse is missing a weir. PIC will provided replacement weir.

View this inspection on the county portal ›

Apr 22, 2020 6 demerits · 2 violations
Inspector comments: 70 GPM Facility will be open from 10 am to dusk. Night swimming not permitted. 2. Chlorine level of pool is at 10 ppm. Facility will wait to open due to COVID-19. However, Chlorine shall remain less than 10 ppm before opening to ensure the safety of the residence. I will visit the pool on 4/29 for a chlorine check. No need for a revisit fee. **Facility understands that although the pool is permitted, it will not open until Mecklenburg County and the State of NC declares it to be safe to do so. Inspector wrote name of operator due to COVID-19
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed weir missing from skimmer on left side of the pool. Operator stated that the skimmer weir will be in today.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed two bags of chemicals located on the equipment room floor. CDI- operator placed both bags on a pallet in the chemical room.

View this inspection on the county portal ›

Apr 30, 2019 0 demerits · 0 violations
Inspector comments: No demerits. Facility will be open 10am - dusk. Night swimming not permitted. 8) .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets with large amount of plant debris. CDI: Skimmer baskets cleaned during inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 24, 2018 8 demerits · 3 violations
Inspector comments: Pool with automatic feeder as well as salt system and erosion chlorinator. Salt levels low (600ppm), system still on and running. Follow manufacturer's instructions for maintaining proper salt levels or turning off and bypassing chlorinator. Glass and ceramic bowls and decorative objects in the amenity area. The amenity area is part of the pool deck, maintain free of glass or other breakable objects. Corrected by operator. Deck drains starting to come up. Maintain deck drains in good condtion and such that they do not create a trip hazard. Posted pool hours are 10AM - 10PM. Pool not permitted for night swimming. Operator changed hours to 10AM to Dusk Local permit #18-600061 issued. Permit issued with the following conditions. No night swimming. Maintain amenity area free of glass objects.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. Maintain secure and in good condition.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck sunk around autofill. Maintain deck level with no offsets > 1/2". Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at erosion chlorinator. Fix leak. Mop bucket stored in front of electrical panel and door to chemical storage room. Vacuum hose stored on the floor in the pump room. Maintain at least 3 feet clear walkway around equipment.

View this inspection on the county portal ›

Jun 26, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522, .2537 Decks unobstructed; Observed pool chairs stored within 6ft .

View this inspection on the county portal ›

May 27, 2016 12 demerits · 2 violations
Inspector comments: Note: Pool built without equalizer lines. Indoor area part of the pool deck due to roll up doors. No glass signs posted. Permit will be issued online at Meckpools.charmeck.org in 1-3 business days. Print permit and post a copy in the pool area.
#3 · Water quality: pool water pH −6
pH 7.0. Maintain between 7.2 and 7.8. Corrected to 7.2.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Incorrect PDSC on file. Corrected PDSC form filled out and approved.

View this inspection on the county portal ›