‹ Back to search

0demerits

ONE305 CENTRAL

1305 CENTRAL AVE, LEASING OFFICE, Charlotte, NC 28205
Seasonal Swimming Pool · NC permit/State ID 2060501395
Latest result0 demerits
Last inspectedJun 2, 2026
Inspections on record11
On record sinceJul 5, 2017

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Jul 5, 2017: 6Apr 13, 2018: 6May 1, 2019: 0May 14, 2020: 0Apr 14, 2021: 10May 11, 2022: 4May 3, 2023: 18May 1, 2024: 14Apr 4, 2025: 10Apr 10, 2026: 16Jun 2, 2026: 0
Jul 5, 2017Lower is betterJun 2, 2026

Inspections & violations

Jun 2, 2026 0 demerits · 0 violations
Inspector comments: PERMIT ISSUED POOL IS NOT PERMITTED FOR NIGHT SWIMMING NO VIOLATIONS NOTED DURING INSPECTION CPO IS JIMMIE BETHEA FLOW METER MEASUREMENT: 115 GPM Permit Restriction: Flow meter must remain operable. Flow required at 102 gpm to 126 gpm to meet turnover and flow restriction of the filter. EHS verified the following during inspection: -New Pump Pentair IntellifloVS + SVRS, 3 hp pump -Blue white flow meter reading the range listed above. -Main drain, skimmer, and return line all 3” line -(2) Lawson MLD-SG-0909 2008 drain covers -(1) Hayward HCF342T filter -(9) returns -(4) skimmers with EQ lines disabled on wall and in skimmer.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 10, 2026 16 demerits · 3 violations
Inspector comments: PERMIT DENIED No night swimming. Filtration pump does not match PDSC form. Pump observed in field is Pentair Intelliflo VS+SVRS. PDSC submission and approval required before permit can be issued. For re-inspection call the front office: 980-314-1620
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH measuring 8.2 according to EHS test kit. CDI: CPO lowered pH to 7.5 by end of inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. CPO states that pump was replaced two months prior. PDSC does not match pump that was observed in the field. Replacement pump is Pentair intelliflo SV + SVRS. New PDSC submission and approval required before permitting. PERMIT DENIED.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed two out of four weirs missing. Replace.

View this inspection on the county portal ›

Apr 4, 2025 10 demerits · 2 violations
Inspector comments: INTELLIFLO FILTRATION MUST BE SET AT 3110 RPM. INSPECTION VERIFIED SET AT 3110 RPM. PUMP MUST REMAIN LOCKED IN PLACE AT ALL TIMES. ‘ FLOW METER MUST REMAIN OPERABLE AND NOT TO EXCEED 126 GPM. INSPECTION VERIFIED 100 GPM. OUTDOOR HANDLES ON GATE MUST NOT PROTRUDE >1/2” AND MEASURE >45” FROM GROUND. BUILT WITHOUT EQUALIZERS. NIGHT SWIMMING NOT PERMITTED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Gate and door did not self close and latch all the way CDI - Hinges fixed on site to self close and latch.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Incorrect phone number posted as Kings III and 9-1-1 had a different phone number, Posted phone number changed to 472-233-4501

View this inspection on the county portal ›

May 1, 2024 14 demerits · 3 violations
Inspector comments: CPO, Deon Bethea, Present during the inspection. Verified main drains and pumps. Night swimming prohibited.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed the reagent #2 expired this April. Provide a new one
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed the ring bouy rope too short. CDI - CPO provide a new rope and cut to the appropriate length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed all apartment windows, except for one with window limiters. Apartment across from the fitness center. CDI - CPO added the limiters to the windows.

View this inspection on the county portal ›

May 3, 2023 18 demerits · 4 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Observed all expired chemicals in chemical test kit available in facility. Chemicals reading near inspector test kit. Obtain new test kit with in date chemicals prior to 05/12/2023 or permit action may be taken.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. - Observed 1 out of 4 weirs missing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed rope attached to ring buoy be 35’10” but required rope length is 37’6”. - CDI - CPO corrected rope length while inspector present.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. - Permit restrictions require pump to be set and locked at 3110 RPM or lower. Observed pump set at 3150 RPM. - CDI - CPO corrected pump to be set at 3110 RPM.

View this inspection on the county portal ›

May 11, 2022 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers with debris. CDI - Debris was removed during inspection.

View this inspection on the county portal ›

Apr 14, 2021 10 demerits · 2 violations
Inspector comments: Apartment has ground level resident rooms with patios. Patios have appropriate fencing but residents have personal items (chairs, tables, flower pots) that all constitute as a foot hold. Informed CPO on site and facility will let all residents know to move or reposition items to remove footholds.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope was not 1.5 times the width of pool. Rope was 27 feet but a rope with 37 feet was required. CDI- Rope of 37 feet was brought out.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Gate did not self close and latch. CDI- Gate repaired and now self closes and latches.

View this inspection on the county portal ›

May 14, 2020 0 demerits · 0 violations
Inspector comments: Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order. Night swimming NOT approved. No violations noted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 1, 2019 0 demerits · 0 violations
Inspector comments: Facility does not do night swimming Permit restrictions: Intelliflo Filtration pump must be set at 3110 RPM or less per passcode Pump must remain locked in place at all times Outdoor handles on gates must not protrude >1/2" Handles must be at least 45" in height from horizontal/ground Windows onto pool deck may not open greater than 4"

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 13, 2018 6 demerits · 2 violations
Inspector comments: 16) Gate into pool self-closes, self-latches, but was slow to close due to wind during visit. Ensure gate remains self-closing self-latching. Pre-permit inspection. Permit issued . Permit restrictions: Night swimming is NOT permitted. Intelliflo Filtration pump must be set at 3110 RPM or less per passcode. Pump must remained locked in place at all times. Outdoor handles on gates must not protrude >1/2". Handles must be at least 45" in height from ground/horizontal. Windows onto pool deck may not open greater than 4".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
One chair being used by resident within 6' of pool. Maintain 6' clear walking space free of trip hazards. Chair being moved when no longer in use. Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water over 110 degrees F in restroom. Maintain hot water at 110 degrees F and below (not permit action item)

View this inspection on the county portal ›

Jul 5, 2017 6 demerits · 1 violation
Inspector comments: Permit issued with the following conditions. No Night Swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 35.5 feet long. Provide US Coast Guard approved ring buoy with 37.5 foot throw rope. Corrected by operator.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ONE305 CENTRAL” or State ID 2060501395). Inspection type (routine vs. follow-up) is not published in the county's data.