GRAMERCY SQUARE AT AYRSLEY

3201 WINDSHIRE LN, Charlotte, NC 28273
Seasonal Swimming Pool · NC permit/State ID 2060501399
Latest result12 demerits
Last inspectedApr 20, 2026
Inspections on record9
On record sinceMay 16, 2018

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 May 16, 2018: 6Apr 4, 2019: 4May 5, 2020: 4Apr 5, 2021: 0May 25, 2022: 4Apr 6, 2023: 0Apr 16, 2024: 4May 8, 2025: 8Apr 20, 2026: 12
May 16, 2018Lower is betterApr 20, 2026

Inspections & violations

Apr 20, 2026 12 demerits · 3 violations
Inspector comments: Inspection conducted with CPO, Chris Cunniff. Permit restrictions: 1. Filtration pump must be set at 3450RPM to meet turnover at 110GPM. 2. Feature flow meter must remain operable with flow at 75GPM due to feature pipe size restriction. Field verification complete. Interlock tested and operational. Not approved for night swimming Permit issued
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed back clubhouse door which opens onto pool deck not self closing. Corrected- Door locked by CPO. Patrons come in through side door near restrooms which self close and latch. CPO confirms the door is checked to ensure it remains locked with daily onsite checks.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed lounge chairs <4ft ft from pools edge. Corrected- Lounge chairs moved back 6ft from pools edge.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed main pump flow meter non-operational. Corrected- CPO repaired meter. Main pump flow observed at 115GPM, feature flow observed at 60GPM.

View this inspection on the county portal ›

May 8, 2025 8 demerits · 2 violations
Inspector comments: Expired covers were replaced and PDSC form updated. EHS accompanied by Geovani Cifuentes, CPO during inspection. Not permitted for night swimming. All non-compliant items were corrected during inspection. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in all skimmer baskets at time of inspection. CDI- CPO cleaned skimmer baskets.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was not working at time of inspection. CDI- CPO repaired flow meter and it is now working properly.

View this inspection on the county portal ›

Apr 16, 2024 4 demerits · 1 violation
Inspector comments: No night swimming permitted 115 GPM Main Drain covers will expire on December 2024. Pool will be open from Dawn to Dust.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed leaf debris in Kimmel baskets. Debris removed during inspection.

View this inspection on the county portal ›

Apr 6, 2023 0 demerits · 0 violations
Inspector comments: No violations were observed during the inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 25, 2022 4 demerits · 1 violation
Inspector comments: Items field verified Feature: Flow meter must remain operable with flow at 75 gpm due to feature return pipe size. Pentair Intelliflo VSF 011056 pump (2) Aquastar 1216xxx drain covers with teal dot. Main drain line = 3”; (3) 1” return lines. Filtration: Pump must remain at speed 3450 rpm. New Pump: Pentair Intelliflo 011056 Piping MD, Skimmer, and return all 3” pipe (2) Aquastar 12MFxxx drain covers (4) skimmers with (4) Waterway 640-803 equalizer line covers (1) Pentair TR140C filter 8 floor or wall returns
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one missing weir. CDI-replaced

View this inspection on the county portal ›

Apr 5, 2021 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 5, 2020 4 demerits · 1 violation
Inspector comments: night swimming not approved
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed leaf debris in skimmer baskets, removed during inspection

View this inspection on the county portal ›

Apr 4, 2019 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
15A NCAC 18A .2528 Ground level door did not self latch. CORRECTED. PIC corrected door to self latch.

View this inspection on the county portal ›

May 16, 2018 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed a loose ladder. Tighten.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a gate not self closing/latching. CDI- Tightened. Self closing/latching now. Per front office staff, No Night Swimming. Permit issued: 18-600629 Report emailed to: gramercysquare@simpsonhousing.com

View this inspection on the county portal ›