‹ Back to search

14demerits

COURTYARDS OF HUNTERSVILLE, THE

8314 PARKNOLL DR, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060501400
Latest result14 demerits
Last inspectedApr 15, 2026
Inspections on record9
On record sinceApr 24, 2018

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0714 Apr 24, 2018: 0Apr 18, 2019: 4Apr 13, 2020: 2Apr 9, 2021: 10Apr 4, 2022: 12Apr 19, 2023: 10Apr 16, 2024: 0Apr 2, 2025: 8Apr 15, 2026: 14
Apr 24, 2018Lower is betterApr 15, 2026

Inspections & violations

Apr 15, 2026 14 demerits · 3 violations
Inspector comments: No permit restrictions No night swimming Inspection completed with CPO Jeremy Laurer
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length > 27ft. CDI: rope length corrected to 27’ on site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate to pool deck unable to self-close self-latch. CDI: CPO adjusted gate to properly self-close and self-latch.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool lounge chairs less than 6 feet from pool edge. CDI: CPO rearranged chairs to allow for 6 feet clearance.

View this inspection on the county portal ›

Apr 2, 2025 8 demerits · 2 violations
Inspector comments: Permit Issued. No night swimming.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate to pool deck unable to self-close self-latch. CDI: CPO adjusted gate to properly self-close and self-latch.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool lounge chairs less than 6 feet from pool edge. CDI: CPO rearranged chairs to allow for 6 feet clearance.

View this inspection on the county portal ›

Apr 16, 2024 0 demerits · 0 violations
Inspector comments: Pool passed the inspection. No night swimming

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 19, 2023 10 demerits · 2 violations
Inspector comments: Verified main drains and pumps. Night swimming is not permitted. Patrick Hurst, CPO was present during the inspection. Permit issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope length to ring buoy 2’ too short. CDI - CPO added new rope with the required length of 27’.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter gauge was not functioning. CDI - CPO cleared the meter and gauge is properly functioning.

View this inspection on the county portal ›

Apr 4, 2022 12 demerits · 3 violations
Inspector comments: No night swimming allowed. Inspection on 4/12/22.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Baskets needed to be cleaned. Keep baskets clean.
#22 · Premises: emergency telephone provided −6
Phone did not work. Replaced during inspection. It is now working properly.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror is not shatterproof.

View this inspection on the county portal ›

Apr 9, 2021 10 demerits · 4 violations
Inspector comments: Night swimming prohibited. Operator stated that pool will not be doing night swimming.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed one set of chairs and table on pool deck not providing 6ft deck clearance. Chairs and table moved back to provide 6ft.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemicals in bags stored on the floor of pump and chemical room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. Observed no shower sign posted. Shower sign was posted by pool operator during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors not shatterproof in restrooms. .2526(i) Water in restrooms shall not exceed 110 F. Observed water in women’s restroom > 110F.

View this inspection on the county portal ›

Apr 13, 2020 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors in bathroom are not shatterproof.

View this inspection on the county portal ›

Apr 18, 2019 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed restroom doors that open directly to pool deck and also lead to clubhouse that are self closing but not self latching. PO corrected door latches to self latch. GENERAL COMMENT: Permit item corrected, permit issued.

View this inspection on the county portal ›

Apr 24, 2018 0 demerits · 0 violations
Inspector comments: Verified PDSC information. Night Swimming not approved.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “COURTYARDS OF HUNTERSVILLE, THE” or State ID 2060501400). Inspection type (routine vs. follow-up) is not published in the county's data.