0demerits
ENCLAVE APARTMENTS
710 E 7TH ST, Charlotte, NC 28202
Seasonal Swimming Pool · NC permit/State ID 2060501405
Latest result0 demerits
Last inspectedMay 12, 2026
Inspections on record10
On record sinceApr 5, 2018
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 5, 2018Lower is betterMay 12, 2026
Inspections & violations
May 12, 2026 0 demerits · 0 violations
Inspector comments: PERMIT ISSUED.
NO VIOLATIONS NOTED DURING INSPECTION
CPO IS GINA VON CASSIDY
POOL IS NOT PERMITTED FOR NIGHT SWIMMING
FLOW METER MEASUREMENT: 82 GPM
No violations were recorded for this inspection.
May 15, 2025 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED
NIGHT SWIMMING NOT PERMITTED.
No violations were recorded for this inspection.
May 14, 2025 12 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Ph recorded at 7.0
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
A return jet cover was placed over Vaccum outlet. Close Vaccum outlet
May 8, 2024 12 demerits · 3 violations
Inspector comments: CPO, Von Cassidy present during the inspection.
Verified main drains and pump.
Night swimming prohibited.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 3 out of the 4 weirs missing. CDI - CPO replaced.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate not self closing. CDI - CPO repaired the gate.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed one window (workout room) open more than 4”. CDI - CPO installed a screw so that the window cannot be opened more than 4”.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no extra basket for pump. Provide.
Apr 18, 2023 14 demerits · 3 violations
Inspector comments: Inspection conducted with CPO, Jason DaRosa. All non-compliant items corrected during inspection.
PDSC information verified. No permit restrictions.
No night swimming.
Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed x2 skimmers missing their weir. CDI - CPO produced and installed x2 new weirs during inspection. -4-
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed 1 of 2 access gates unable to self-close. CDI - CPO adjusted gate hinge hardware and access gate now self-closing. -4-
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed pool emergency phone dial back number inoperable. Number assigned to emergency phone dialing out to apartment elevator. CDI - CPO and onsite staff corrected switchboard system and phone now operable. -6-
May 17, 2022 8 demerits · 2 violations
Inspector comments: All violations corrected during inspection
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed abundance of debris in skimmers. CDI - Skimmers were emptied during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed access gate to resident's apartment not self latching. It was determined that tape was placed on latch to prevent latch from fully closing. CDI - Tape was removed and gate was able to latch correctly.
Apr 13, 2021 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
One skimmer missing weir. CDI- Weir replaced on site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Solid barriers that do not have openings shall not contain indentations or protrusions except for normal construction tolerances and tooled mansonry joints.
Pool has multiple gates and fencing around area that is a part of residential rooms (porch/patios). Residents have personal furniture, flower pots, etc that create a foothold to the gate and fence. CPO will ask residents to remove footholds. Pool built after 2010.
Apr 29, 2020 10 demerits · 2 violations
Inspector comments: Night swimming NOT approved.
All 4 and 6 point demerit items in compliance by end of inspection.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length above required length. CDI: rope was cut to proper length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed two access gates from renter porches that were not self-latching. CDI: Gate tensions adjusted and brought into compliance.
May 13, 2019 0 demerits · 0 violations
Inspector comments: No night swimming
permit issued.
No violations were recorded for this inspection.
Apr 5, 2018 12 demerits · 2 violations
Inspector comments: Issued permit 18-600043. Night swimming is not permitted.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Observed chloring at 0.5ppm. Adjusted to 1.5 on site.
#3 · Water quality: pool water pH −6
Observed pH ay 7.0. Adjusted on site to 7.3.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ENCLAVE APARTMENTS” or State ID 2060501405). Inspection type (routine vs. follow-up) is not published in the county's data.