‹ Back to search

12demerits

COURTYARDS AT KINNAMON PARK

9510 FAWNTAIL LN, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060501415
Latest result12 demerits
Last inspectedMay 12, 2026
Inspections on record10
On record sinceMay 25, 2018

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 May 25, 2018: 0Jun 7, 2018: 28Apr 18, 2019: 10May 7, 2020: 0May 6, 2021: 4Apr 27, 2022: 4Apr 14, 2023: 0May 6, 2024: 0May 7, 2025: 0May 12, 2026: 12
May 25, 2018Lower is betterMay 12, 2026

Inspections & violations

May 12, 2026 12 demerits · 3 violations
Inspector comments: Permit restrictions: Digital flow meter must remain operable. Flow required at least 58gpm to meet turnover. No night swimming. Inspection completed with CPO Michael Morgan
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no phone number posted on emergency phone sign. CDI: operator wrote correct phone number on sign; phone number also properly dialed back to pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed digital flow meter not working due to batteries. CDI: operator replaced batteries and flow meter is now working properly.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed some lights out in the women’s restroom.

View this inspection on the county portal ›

May 7, 2025 0 demerits · 0 violations
Inspector comments: FLOW METER MUST REMAIN OPERABLE. FLOW REQUIRED AT LEAST 58 GPM TO MEET TURNOVER. NO NIGHT SWIMMING. NO VIOLATIONS NOTED

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 6, 2024 0 demerits · 0 violations
Inspector comments: NO NIGHT SWIMMING

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 14, 2023 0 demerits · 0 violations
Inspector comments: No violation observed, Mr Sawyer Pierce present during the inspection. This item may need to be replace by summer: 1. Ring buoy and rope starting to fray and unglue from the ring. Recommend to keep a spare set in the facility when needed. Rope length is 30’. NOTE: Digital flow meter read 97 GPM

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 27, 2022 4 demerits · 1 violation
Inspector comments: Night swimming not permitted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed main gate unable to self-close. CDI: CPO repaired gate- now self-closes/self-latches. REPEAT

View this inspection on the county portal ›

May 6, 2021 4 demerits · 1 violation
Inspector comments: Night swimming NOT permitted. Inspection conducted with Michael Morgan. Report to and No signature due to COVID-19.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed main gate unable to self-close. CDI: CPO repaired gate- now self-closes/self-latches.

View this inspection on the county portal ›

May 7, 2020 0 demerits · 0 violations
Inspector comments: Inspection conducted with Benji Sheehan. Due to COVID-19 precautions, inspection was not signed by the operator. Issues from previous inspection corrected. New main drain covers installed and PDSC form approved. Restrooms locked, unable to inspect. Maintain restrooms in good condition and accessible to bathers when the pool is open. No other issues observed. Permit issued. No night swimming. “Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 18, 2019 10 demerits · 2 violations
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed posted pool sign in .5" lettering. PO removed and provided proper sign in 1" lettering.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Pool phone not visible from all areas of pool, no location sign provided. PO provided a temporary pool location sign visible from all parts of pool. Be sure a more permanant sign is posted ASAP. GENERAL COMMENT: Observed pool chlorine above 10 ppm but less than 50 ppm. Chlorine above 50 ppm is dangerous. Be sure to maintain chlorine at safe levels. Permit items corrected. Permit issued.

View this inspection on the county portal ›

Jun 7, 2018 28 demerits · 7 violations
Inspector comments: Intent to Suspends issued for the following: 2528 - Large gate not self-closing. Repair to self-close. Meshing around push bar too large. Maintain no greater than 1/2" within 18" of latch mechanism. Meshing is 1/2" x 3/4". Green utility cover provides foothold next to fence. Eliminate foothold. 44 1/2" between horizontals on right side of large fence from outside. Maintain 45" between horizontals. 2535 - record alkalinity and acid weekly 2518 - Flow meter must meet 1.5x design flow of pump at least 135 gpm. Small leak at pipe at multi-port. Repair leak. 2533/2534 - Storage of chemicals in pump room and storage on floor in pump room. Provide 3 ft clear walking space around all equipment and maintain chemical storage in chemical storage room. 2526 - provide documentation for shatterproof mirrors in restrooms PDSC form is on old form with no date for expiration. PDSC form references incorect drain cover. Field built sumps. Engineer letter references WAV12 and not WAV12WRxxx which are what is installed. No suction hazard present. Property given one week to provide updated sump certification letter and updated PDSC form. Max Depth - 4 ft Pool Width - 20 ft Rope Length - 30 ft Pentair Whisperflo WFE-6 with (2) WAV12WRxxx drain covers
#3 · Water quality: pool water pH −6
Pool pH at 8.2. Corrected to 7.2 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid and alkalinity not recorded weekly. Record weekly. Intent to Suspend issued. One day with chlorine at 0 ppm. Pool not closed. If pool chlorine is below 1 ppm, pool shall be closed. Corrective actions shall be written in the log book.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Large gate not self-closing. Repair to self-close. Meshing around push bar too large. Maintain no greater than 1/2" within 18" of latch mechanism. Meshing is 1/2" x 3/4". Both gates. Green utility cover provides foothold next to fence. Eliminate foothold. 44 1/2" between horizontals on right side of large fence from outside. Maintain 45" between horizontals. Intent to Suspends issued for all listed items above.
#22 · Premises: emergency telephone provided −6
Dialing instructions incorrect and address incorrect at emergency phone. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter does not meet 1.5 x design flow. Required to read at least 135 gpm. Flow meter must show required flow. Blue white flow meter installed. Ensure installed per manufacturer instructions. Intent to suspend issued. Small leak at pipe at multi-port. Repair leak. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Storage of chemicals in pump room and storage on floor in pump room. Provide 3 ft clear walking space around all equipment and maintain chemical storage in chemical storage room. Intent to Suspend issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No documentation for shatterproof mirrors. Provide documentation for shatterproof mirrors. Intent to Suspend issued. General Comment - No paper towels in the men's restroom. Provide paper towels.

View this inspection on the county portal ›

May 25, 2018 0 demerits · 0 violations
Inspector comments: Verified PDSC information.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “COURTYARDS AT KINNAMON PARK” or State ID 2060501415). Inspection type (routine vs. follow-up) is not published in the county's data.