‹ Back to search

12demerits

ARIUM FREEMORE WEST APARTMENTS

2024 MILLERTON AVE, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060501433
Latest result12 demerits
Last inspectedApr 21, 2026
Inspections on record9
On record sinceApr 24, 2019

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Apr 24, 2019: 4May 8, 2020: 10Apr 14, 2021: 2Jul 7, 2022: 0Apr 19, 2023: 16May 13, 2024: 10May 14, 2025: 18May 20, 2025: 8Apr 21, 2026: 12
Apr 24, 2019Lower is betterApr 21, 2026

Inspections & violations

Apr 21, 2026 12 demerits · 2 violations
Inspector comments: Night swimming not allowed
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Rope longer than 45’ (required). Cut during the inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Incorrect number listed at emergency phone. Correct number posted during the inspection

View this inspection on the county portal ›

May 20, 2025 8 demerits · 3 violations
Inspector comments: Pool inspection conducted with Toby Thompson, CPO. Pool restrictions: 1. Salt not approved as primary chlorination. Not: Rolling doors leading on to pool deck area in fitness becomes pool deck once opened. No glass. Note: No glass signage required in fitness room. Pool hours are from dawn til dusk. 45 GPM
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Clean pollen from pool floor and pool walls throughout pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemicals not in waterproof containers that were stored on the floor. CDI- Chemicals were stored on pallet.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Provide information to show that mirrors are shatterproof in restrooms.

View this inspection on the county portal ›

May 14, 2025 18 demerits · 4 violations
Inspector comments: Replace Chlorinator with one that is appropriately sized for pool. Pool is denied. Call office to pay revisit fee before scheduling. Toby Thompson is the New CPO.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Remove pollen stains from pool wall and floor.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Ring buoy present a pool was in bad repair. CPO will replace ring buoy before permitting.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed area of fence to the right of pool from clubhouse that was >4 inches. CDI- CPO repaired area so that it is less than 4 inches.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Chlorinator is in bad repair. Chlorinator was repaired with tape, but leaking from the top area. Replace Chlorinator before permitting.

View this inspection on the county portal ›

May 13, 2024 10 demerits · 2 violations
Inspector comments: No night swimming permitted
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Lots of debris in pool. Vacuum out pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope measured 33 feet. CDI - Operator acquired 45 foot rope by end of inspection.

View this inspection on the county portal ›

Apr 19, 2023 16 demerits · 4 violations
Inspector comments: EHS conducted inspection with CPO Kenneth Booker. PDSC information and permit restrictions verified. Non-compliant items corrected with exception of 75 % of weirs installed at 3 of 4 skimmers. Property management has ordered extra equipment through their pool experts supplier and is expecting an ETA between 4/20-4/21. EHS will return to facility to verify it’s installation. Night swimming not permitted. Permit issued.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be at 7.0. CDI - CPO corrected and now reading at 7.2. -6-
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 of 4 skimmers missing it’s weir. -4-
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area. “No glass” signage not provided in fitness room. CDI - CPO placed signage on x2 doors stating “no glass allowed at pool”. -4-
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed pool chemicals stored on floor. CDI - CPO removed chemicals from floor. -2-

View this inspection on the county portal ›

Jul 7, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. NIGHT SWIMMING NOT PERMITTED. AS OF DATE OF PERMIT (7/7) FACILITY HAS A PERMIT RESTRICTION THAT PROHIBITS USE OF FEATURE JETS DUE TO INCOMPLETE VGB PAPERWORK FOR PDSC DRAINS. FEATURE JETS MUST REMAIN INOPERABLE UNTIL PDSC PAPERS ARE COMPLETED AND APPROVED BY HEALTH DEPARTMENT. YOU HAVE UNTIL JULY 17TH TO SUBMIT PDSC FORMS OTHERWISE POOL MAY BE SUBJECT TO CLOSURE.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 14, 2021 2 demerits · 1 violation
Inspector comments: Night swimming permitted. Documentation for night swimming that was done last year will still be in effect. All lighting is in working order. 55 GPM Pool is allowed to open according to the state mandate on amount of people in pool at one given time. Main drain covers expire January '22. Change covers before next pool permitting season.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. No verification that the mirrors in restrooms are shatterproof. .2526(m) Keep restrooms and fixtures clean and in good repair. Tighten loose toilet seat in men's restroom.

View this inspection on the county portal ›

May 8, 2020 10 demerits · 2 violations
Inspector comments: 17. Large cracks in pool deck have been properly repaired. Only small cracks less than 1/2" remain. Night swimming permitted. **Facility understands that although the pool is permitted, it will not open until Mecklenburg County and the State of NC declares it to be safe to do so.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. No screws were in place on body hook to prevent telescoping at start of inspection. CDI- Pool operator installed proper screws into body hook. No further permit action taken since corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not properly working at time of inspection. Pool Operator will repair or replaced flow meter.

View this inspection on the county portal ›

Apr 24, 2019 4 demerits · 1 violation
Inspector comments: Night swimming will not be verified until all lights are visible at night. Night swimming will not take place until this is done. Pool hours will be from dawn til dusk until verified.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed large crack in deck on right side of pool. Crack is beginning to get 1/4" in width. Repair crack in deck.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ARIUM FREEMORE WEST APARTMENTS” or State ID 2060501433). Inspection type (routine vs. follow-up) is not published in the county's data.