‹ Back to search

0demerits

HAVEN AT RIVERGATE, THE

14710 KILKENNY HILL LANE, Charlotte, NC 28273
Seasonal Swimming Pool · NC permit/State ID 2060501452
Latest result0 demerits
Last inspectedMay 12, 2026
Inspections on record10
On record sinceMay 24, 2019

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 May 24, 2019: 0Jun 10, 2019: 16May 6, 2020: 0Apr 8, 2021: 2Apr 4, 2022: 16May 10, 2023: 10May 17, 2024: 0Apr 30, 2025: 2May 6, 2026: 18May 12, 2026: 0
May 24, 2019Lower is betterMay 12, 2026

Inspections & violations

May 12, 2026 0 demerits · 0 violations
Inspector comments: Permit Restrictions: Night swimming is NOT permitted. No violations noted during inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 6, 2026 18 demerits · 4 violations
Inspector comments: Chlorine was out also. Initial measurement 0.4. Corrected- 2.0. Discussed and on form. However, not entered prior to signing.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Minor debris in skimmer baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Throw rope only 30 ft. Corrected- new 50 ft throw rope installed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Gate next to main office did not self-close. Corrected- adjusted to self-close properly.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Different wording and text <3/4” tall. Must be exact wording and minimum of 1” tall text. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Different wording and text <3/4” tall. Must be exact wording and minimum of 1” tall text.

View this inspection on the county portal ›

Apr 30, 2025 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed liquid chemicals stored on shelving above dry chemicals (pool shock.) CDI - CPO relocated chemicals to lower storage.

View this inspection on the county portal ›

May 17, 2024 0 demerits · 0 violations
Inspector comments: No night swimming permitted. 100 GPM Pool will be open from dawn til dusk according to management.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 10, 2023 10 demerits · 2 violations
Inspector comments: No Night Swimming Unable to verify shatterproof mirrors in the bathrooms.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope observed to be 60'. Cut to required length during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate closest to the leasing office observed not self closing. Mechanism was repaired during visit.

View this inspection on the county portal ›

Apr 4, 2022 16 demerits · 4 violations
Inspector comments: CPO Luis was present during the inspection. Per permit and insufficient lighting there shall not be any night swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed 2 out of four skimmer baskets with debris. CDI- CPO cleaned out baskets.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed ring buoy rope at 60 Ft. CDI- CPO provided ring buoy rope at 50Ft.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. - Observed several lounge chairs at 5Ft from the pools edge. CDI- CPO moved chairs to 6Ft.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. - Observed mirrors in restrooms without documentation of being shatterproof.

View this inspection on the county portal ›

Apr 8, 2021 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in restrooms not shatterproof.

View this inspection on the county portal ›

May 6, 2020 0 demerits · 0 violations
Inspector comments: Verified PDSC information. Observed no non-complaint conditions.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 10, 2019 16 demerits · 4 violations
Inspector comments: 25 - No fresh air intake in chemical storage room or pump room. Required per mechanical inspector. Verify with engineer on sizing. 30 days given for repair. Battery back-up verified at time of inspection. PDSC form verified at time of inspection. Intent to suspend issued for log book, weir, autofill cover, and gates/fencing.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed pool pH at 8.0 for 6/10. Operator indicated chemistry was adjusted by chemical addition. Provide section in log book for notes and comments. Intent to Suspend issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer missing weir. Replace weir. Intent to Suspend issued.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Autofill missing fitting. Provide fitting to eliminate 2" opening in side wall to prevent entrapment hazard. Intent to Suspend issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
All gates with 1" between post and gate at hinge location. Maintain no openings >1/2" within 18" of latch mechanism. Gate (left side) with >2" under gate from ground to bottom horizontal. Maintain 2" or less under gates. Observed fencing with >2" under fence from ground to bottom horizontal on right side fence and gate. Maintain 2" or less. Intent to suspend issued.

View this inspection on the county portal ›

May 24, 2019 0 demerits · 0 violations
Inspector comments: Observed no non-compliant conditions. Verified PDSC information. Pool Width – 38’ Rope Length – 50’ Max Depth – 4’ Pump – Pentair CHII-NI-2FE Filter – Pentair TR 140C Main Drain – Aquastar 914xxx Permit Restrictions 1) Salt not approved as primary chlorination 2) Pool not approved for night swimming.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HAVEN AT RIVERGATE, THE” or State ID 2060501452). Inspection type (routine vs. follow-up) is not published in the county's data.