PROVIDENCE COURT APARTMENTS II

1806 NANTUCKETT LN, Charlotte, NC 28270
Seasonal Swimming Pool · NC permit/State ID 2060501476
Latest result12 demerits
Last inspectedJul 1, 2026
Inspections on record7
On record sinceMay 13, 2020

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 May 13, 2020: 14Apr 30, 2021: 8May 17, 2022: 16Jul 11, 2023: 0Jun 18, 2024: 0Jun 4, 2025: 4Jul 1, 2026: 12
May 13, 2020Lower is betterJul 1, 2026

Inspections & violations

Jul 1, 2026 12 demerits · 2 violations
Inspector comments: No night swimming. Expiring Equalizer Covers - Requires replacement 2026Permit Restriction: Flow meter must remain operable. Flow shall not exceed 119 gpm due to drain cover flow restriction. Suction Hazard.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH reading below scale on test kit. EHS estimated 6.5. CDI - Corrected to 7.2
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect pool phone number posted. CDI - pool number corrected.

View this inspection on the county portal ›

Jun 4, 2025 4 demerits · 1 violation
Inspector comments: Pool inspection completed with CPO Jeremy Hill Equalizer lines expire 11/25, must be replaced before 2026 pool season to be permitted. Flow meter observed operable. Flow meter not to exceed 119 GPM.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer CDI - Skimmer cleared of debris.

View this inspection on the county portal ›

Jun 18, 2024 0 demerits · 0 violations
Inspector comments: Change the ring buoy at the end of the season. Phone connected to kings 3 and 911. When you call it back the red button light comes on, blinks but hangs up once you pick it up. Spoken to Tim about this.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 11, 2023 0 demerits · 0 violations
Inspector comments: Pool is open for 2023 season. No night swimming permit. Pool flow is less than 119 gpm, verified during inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 17, 2022 16 demerits · 5 violations
Inspector comments: Night swimming is NOT approved. Contact your local health department for approval.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed debris on pool surface and floor. EHS still able to see bottom of pool floor and main drains. CDI- CPO started cleaning pool during the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.- Observed debris in pool skimmers. CDI- CPO removed debris from skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. - Observed one gate not self closing and self latching. CDI- CPO made corrections to gate. EHS observed all gates self closing and self latching.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors.- CPO and EHS unable to verify glass mirrors are shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observed hose bib within 50 ft of pool without proper back flow prevention.

View this inspection on the county portal ›

Apr 30, 2021 8 demerits · 2 violations
Inspector comments: no night swimming
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
gate was broke on the side. New mount was installed during inspection
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
flow meter stuck but corrected during inspection

View this inspection on the county portal ›

May 13, 2020 14 demerits · 3 violations
Inspector comments: PERMIT ISSUED. STICKER ISSUED. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” POOL HAS AQUASTAR A10RCFR EQ LINE COVERS. THESE COVERS EXPIRE SEPTEMBER 2020. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM. NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed weirs missing in 3 of the 4 skimmers. Weirs were replaced. -CDI
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed body hook pole to be collapsible. A non-collapsible body hook pole of at least 12 foot length is required. A proper body hook pole was provided. -CDI.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence gaps greater than 4 inches in some places. No permit action taken. Fence was built prior to 2010. Observed some gates not fully self closing and not fully self latching. Gates were corrected. -CDI