‹ Back to search

2demerits

LANTANA

6518 WILDBROOK DR, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060501480
Latest result2 demerits
Last inspectedMay 6, 2026
Inspections on record9
On record sinceJun 5, 2020

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Jun 5, 2020: 2Jul 29, 2020: 4Apr 21, 2021: 4May 12, 2022: 4Apr 13, 2023: 2Apr 12, 2024: 6Apr 15, 2025: 10Apr 15, 2026: 18May 6, 2026: 2
Jun 5, 2020Lower is betterMay 6, 2026

Inspections & violations

May 6, 2026 2 demerits · 1 violation
Inspector comments: PERMIT RESTRICTION: 1) Flow meter must remain operable. Flow required at 167 gpm- 238 gpm to meet turnover and flow restriction of the suction piping. Flow meter greater than 400 gmp exceeds the main drains. Suction hazard. 2) Dialing instructions posted at emergency phone must read to transfer to Charlotte 911 dispatch. Answered by Concord dispatch. NOTE: All required changes verified during inspection. New Pump Pentair EQK500, 5 hp Aquastar FM40 flow meter reading in the above range. Main Drain, Skimmer and return line all 4” line. (2) Pentair TR140C filters (12) returns (either on the floor or the wall) (6) skimmers with EQ lines disabled on wall and inside skimmer.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof.

View this inspection on the county portal ›

Apr 15, 2026 18 demerits · 4 violations
Inspector comments: Dialing instruction posted at emergency phone must read request transfer to Charlotte 911. Dispatch answered by Concord dispatch. No night swimming Permit denied
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed pool with new pump. Pump has not been verified with new PDSC form.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope over 50ft. CDI- Rope cut
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed main entrance gate not self-closing self- latching. CDI- Gate fixed on site.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof in restrooms.

View this inspection on the county portal ›

Apr 15, 2025 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope greater than 50 ft long. CDI PO cut rope to 50 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Observed 4-6 inches under some areas of the fence. CDI PO put straw and mulch along bottom of gate. PO will purchase more to go around the entire perimeter fence.

View this inspection on the county portal ›

Apr 12, 2024 6 demerits · 1 violation
Inspector comments: Phone has sign requesting to transfer call to charlotte 911
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.PH looked a little above 7.8. CDI PH is at 7.6

View this inspection on the county portal ›

Apr 13, 2023 2 demerits · 1 violation
Inspector comments: Permit issued and sign at emergency phone has sign posted reading : REQUEST TRANSFER TO CHARLOTTE 911. DISPATCH ANSWERED BY CONCORD DISPATCH. No night swimming requested.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed dry chemical with puncture in bag spilling on floor and starting a reaction. CDI - Chemical removed and area cleaned during inspection.

View this inspection on the county portal ›

May 12, 2022 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.observed deck furniture within 6ft of pool edge. CDI removed

View this inspection on the county portal ›

Apr 21, 2021 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed weirs missing. Weirs were replaced during the inspection. **.2518(k) Replace missing weirs.

View this inspection on the county portal ›

Jul 29, 2020 4 demerits · 1 violation
Inspector comments: PERMIT RESTRICTION: DIALING INSTRUCTION POSTED AT EMERGENCY PHONE MUST READ REQUEST TRANSFER TO CHARLOTTE 911 DISPATCH ANSWERED BY CONCORD DISPATCH.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one gate getting hung on plant near pump room. .2537(b) All gates and doors shall be self-closing, self-latching. Intent to suspend.

View this inspection on the county portal ›

Jun 5, 2020 2 demerits · 1 violation
Inspector comments: Onsite visit to pool for construction final and permit inspection. Construction final passed. Louie Woods, Edgewater Pools, present during inspection. No signature due to COVID restrictions. Report emailed to Louie Woods, Mike Phillips and Timothy Clontz. Per contractor and pool builder, due to proximity of pool to the County line, phone will alternate between Charlotte and Concord dispatch. Spoke with 911 operator who indicated they would transfer to Charlotte dispatch if comes in on Concord line. Fire department suggested that emergency pool phone signage has dialing instructions to request transfer to 911 dispatch. Added to signage. Pool Width - 51 ft. Rope Length 50 ft. Max Depth - 5 ft. Filtration - Pentair Whisperflo WFE-8, 2 hp (2) with (2) WAV12WRxxx drain covers. EQ lines plugged in skimmer and plastered on wall (capped on underside). Feature - Pentair Superflo VS 1.5 342001, 1.5 hp with (2) WAV9WRxxx drain covers. Permit Restriction 1) Dialing instructions posted at emergency phone must read request transfer to 911 dispatch if answered by Concord dispatch. Permit has been issued for no night swimming. Issuance of a permit by this department does not negate closure required by Executive Order No. 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap, paper towels, or toilet paper in restrooms. Provide prior to opening to the public.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “LANTANA” or State ID 2060501480). Inspection type (routine vs. follow-up) is not published in the county's data.