0demerits
AMAZE @ NODA APARTMENT HOMES
3756 PHILEMON AVE, Charlotte, NC 28206
Seasonal Swimming Pool · NC permit/State ID 2060501482
Latest result0 demerits
Last inspectedMay 19, 2026
Inspections on record9
On record sinceJul 10, 2020
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 10, 2020Lower is betterMay 19, 2026
Inspections & violations
May 19, 2026 0 demerits · 0 violations
Inspector comments: No violations observed today.
No restrictions on the permit.
Facility requesting night swimming. EHS will need to conduct a night inspection before dawn because one of the lights inside the pool is not working.
Night swimming not approved.
No violations were recorded for this inspection.
May 13, 2026 18 demerits · 4 violations
Inspector comments: No permit restrictions
Pump and drain covers verified as being same as PDSC form during inspection
Permit denied today
Facility requesting nighty swimming: EHS will do a night swimming inspection when returning for the re-inspection. EHS educated CPO on the requirements.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine less than 1.0 ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed large amount of debris in skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate facing clubhouse not self closing
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 3 trip hazards on deck around skimmers.
May 8, 2025 0 demerits · 0 violations
Inspector comments: No night swimming
No permit restrictions
Pump and drain covers verified as being same as PDSC form during inspection
No violations noted during inspection
No violations were recorded for this inspection.
May 1, 2024 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed main gate to pool not self latching at time of inspection . CDI PIC adjusted gate and corrected issue.
Apr 4, 2023 4 demerits · 1 violation
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Gate did not self close when swung to a 90 degree angle due to scraping on ground. CDI - Hinges lifted on gate, no longer scraping and self closed all the way
Jun 2, 2022 6 demerits · 1 violation
Inspector comments: PDSC form corrected/approved on site.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
Jun 15, 2021 8 demerits · 3 violations
Inspector comments: Inspection conducted with Jim Davis and maintenance staff. Due to COVID-19 precautions, inspection was not signed by the operator.
Chemical storage room beside pump room had a ventilation system installed and approved by Code Enforcement after the final construction inspection was completed last year.
Recommend providing chemical safety placard for chemical storage room door.
Recommend removing plastic protective coating from stainless steel steps on ladders. Plastic is only designed to protect the product during shipping.
Some anchor holes in deck from where canopies were moved. Recommend filling with cement or other comparable product.
Pre-permit issues from previous inspection have been addressed.
Permit issued
No Night Swimming
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Post for canopy too close to ladder. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. - Corrected.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Return line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. - Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One stall in men's restroom without toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms. - Corrected.
Jun 3, 2021 26 demerits · 8 violations
Inspector comments: Inspection conducted with Matthew Carpenter. Due to COVID-19 precautions, inspection was not signed by the operator.
Mud in the bottom of autofill, hole in the side of the autofill sump. Recommend removing mud and plugging the hole.
Plug equalizer lines per state guidelines by ensuring that water is drained below skimmers and vacuumed out of the equalizer lines prior to plugging them.
Recommend providing chemical safety placard for chemical storage room door.
Had to try a few times before emergency phone dialed 911. Recommend checking that the auto-dialer is working properly.
Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a follow up inspection. This can be done by calling our main office (980) 314-1620 and paying with a credit card.
Permit Denied
5)
12)
16)
17)
24)
25)
26)
29)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Fitting missing for autofill. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
Two of the skimmers missing equalizer line plugs. Plug equalizer lines per state guidelines. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main gate not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Pre-permit item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Post for canopy too close to ladder. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. - Pre-permit item.
Post for canopy too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Pre-permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Self-closing vacuum cap broken. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item.
Flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item.
Filtration pump off, part of the facility lost power. .2518(b) The system shall be operated 24 hours a day. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in pump room. Chemical storage room full of stockpiled chemicals and some non-chemical items. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Pre-permit item.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Return line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. - Pre-permit item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One stall in women's restroom without toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms. - Pre-permit item.
Jul 10, 2020 4 demerits · 1 violation
Inspector comments: Permit issued for no night swimming. A follow-up visit will be completed, unannounced, within 2 weeks of permit issuance.
No signature due to covid restrictions. Emailed to Elaine Ballew and Richard Brady.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Log book not provided. Corrected during inspection.
Richard Brady, CPO, not onsite over weekend. Front office staff has current CPO, Matthew Carpenter, CPO-569457, expires 6/11/2022. Matthew will fill in for CPO over weekend. Management lives on site and must maintain daily.
No test kit. Contractor will leave test kit until facility can provide test kit from local supply store.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “AMAZE @ NODA APARTMENT HOMES” or State ID 2060501482). Inspection type (routine vs. follow-up) is not published in the county's data.