0demerits
1100 SOUTH
1100 SOUTH BLVD, Charlotte, NC 28203
Seasonal Swimming Pool · NC permit/State ID 2060501495
Latest result0 demerits
Last inspectedMay 12, 2026
Inspections on record7
On record sinceApr 1, 2021
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 1, 2021Lower is betterMay 12, 2026
Inspections & violations
May 12, 2026 0 demerits · 0 violations
Inspector comments: Night swimming not permitted
No violations were recorded for this inspection.
Aug 8, 2025 4 demerits · 1 violation
Inspector comments: Inspection for A status. see notes on 8/8 visit
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not installed per manufacturer instructions.
Aug 7, 2025 46 demerits · 11 violations
Inspector comments: Permit denied for the following items.
.2535 - provide log book with section for main drain checks.
.2539 - plug equalizer per State requirement in skimmer.
.2518 - provide skimmer weirs where missing.
.2530 - provide USCG approved ring buoy with 34 ft. rope.
.2528 - secure mesh to gate and repair damage to mesh with openings >1/2" within 18" of push bar or where sharp.
.2530 - provide additional warning signage at main entry gate and move pool rules signage to wall of building.
.2530 - post address at pool phone.
Once items corrected, contact Katie to schedule a return visit. Banks Parmley present during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No logs maintained. Log book does not have a section for maintaining daily record keeping for main drains. Provide section in log book for main drain inspections. Permit denial item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form with incorrect number of skimmers. Should have been listed as 4. Corrected on form. Equalizer lines not plugged in skimmers per State requirement. PDSC form indicates plugged per State recommendations. Plug in skimmers. Permit Denial item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Multiple skimmers missing weirs. Replace weirs. Permit denial item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Deep end ladder not secure. Tighten ladder.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Bubbler returns missing fittings. No offsets >1/2"; no sharp edges. Replace fitting coverings.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Grab rope on ring buoy degrading. Rope for ring buoy degrading. Replace with USCG approved ring buoy and 34 ft. rope. Permit denial item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main gate entry with meshing not secure and damaged in two locations. Ensure no openings >1/2" within 18" of push bar and secure mesh to barrier. Permit denial item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Turf used on deck within 6 ft. of pool edge. Original construction. Pool furniture 5 ft. from pool. Maintain 6 ft. clearance around the pool with impervious surface.
#18 · Premises: lifeguards present or warning signs posted −4
Warning signage and pool rules signage not visible from main entry gate. Move pool rules signage to wall so visible upon entry to the pool and provide additional warning signage at main entry. Warning No Lifeguard on Duty shall be 4" lettering. All signage shall be visible upon entry to the pool. Permit Denial item.
#22 · Premises: emergency telephone provided −6
No address posted at pool phone. Post address. Permit Denial item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower not operable. Per operator, line broke previous day. Keep all fixtures operable.
Apr 29, 2024 20 demerits · 4 violations
Inspector comments: Charles Cline, CPO present during the inspection.
Night swimming prohibited.
Verified pumps and main drains.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed main drain check daily on the daily check log sheet. CDI - CPO added column to log sheet. Observed a couple regents in the the test kit were expired this month or next. CDI - CPO had a new test kit and discarded the old regents.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed two Weirs were not in place, CDI- Weirs placed in and secured.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.Observed new ring buoy was was not USCG approved. CDI - CPO had the old ring bouy which was still in good shape, and replaced.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed the rope exceeding the required length of 34’6”. CDI - CPO cut rope to the required length.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed two phone numbers at the kings three emergency phone. Remove the incorrect phone number from the phone. CDI - CPO covered up the incorrect phone number.
Apr 5, 2023 0 demerits · 0 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
No violations were recorded for this inspection.
Apr 6, 2022 4 demerits · 1 violation
Inspector comments: Recommended a larger emergency phone sign.
Night swimming not permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Weirs were not in place, CDI- Weirs placed in and secured.
Apr 1, 2021 0 demerits · 0 violations
Inspector comments: Inspection completed with Charlie Cline. No signature due to COVID-19. No violations noted during inspection. Previous items out of compliance listed under annual permit #530409 have been brought into compliance. Pool now has seasonal permit.
No violations were recorded for this inspection.