Latest result6 demerits
Last inspectedApr 1, 2026
Inspections on record6
On record sinceApr 8, 2021

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 Apr 8, 2021: 10Apr 12, 2022: 0Apr 4, 2023: 0Apr 18, 2024: 12Apr 1, 2025: 4Apr 1, 2026: 6
Apr 8, 2021Lower is betterApr 1, 2026

Inspections & violations

Apr 1, 2026 6 demerits · 1 violation
Inspector comments: NOTE: Landscaping must remain so that wall depth markers are clearly visible at all times in swimming pool. Condensate line in pump room approved with ramp. Pool approved for night swimming on 4/3/2025.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length at 32 feet, field book states 30 feet. Corrected to 30 feet during inspection.

View this inspection on the county portal ›

Apr 1, 2025 4 demerits · 1 violation
Inspector comments: Pool heater not tested during inspection. CPO instructed to keep pool temperature at 90 F or below. Gate latch by back alleyway towards chemical room is loose. Gate still self-closes/self-latches. CPO will tighten screws. Pool has pending night swimming approval. Night visit to be made at a later date. No night swimming allowed until approval is granted.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Wall depth markers obscured by trees. CDI - CPO trimmed trees to reveal depth markers.

View this inspection on the county portal ›

Apr 18, 2024 12 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope length at 57. CDI. PIC adjusted to 30 as required.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no address or telephone number at pool. CDI. PIC provided one.

View this inspection on the county portal ›

Apr 4, 2023 0 demerits · 0 violations
Inspector comments: Violations noted: .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.8 ppm. CDI- More chlorine added to pool. New reading was measured at 2.0ppm. Permit restrictions: EHS reviewed permit restrictions. Observed depth markers clearly visible on wall. Observed condensate line in pump room. EHS will have to come back to verify all lights are working prior to opening for night swimming. Facility lights are on a timer and cut on around 7:30-8:00. Operator: Ken Rattie

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 12, 2022 0 demerits · 0 violations
Inspector comments: *NOTE: No violations were observed during time of inspection. Director of Engineering Mr. Ken Rattie was present during time of inspection. Report emailed to: Ken.Rattie@unccharlottemarriott.com

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 8, 2021 10 demerits · 2 violations
Inspector comments: Inspection conducted with Ken Rattie and Jay Deans. Due to COVID-19 precautions, inspection was not signed by the operator. Note: Facility installing a liquid chemical feeder. Test to ensure that feeder stops feeding when the pump shuts off. Max Depth - 4ft 6in Pool Width - 20 ft Rope Length - 30 ft Permit issued with the following conditions: Landscaping must remain so that wall depth markers are clearly visible at all times while in the swimming pool. No night swimming.
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.5ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 1 ppm.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Roughly 20 foot section of wall < 48" high due to mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Corrected.