‹ Back to search

4demerits

GRIFF, THE

1831 MOREHEAD RIDGE DR, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060501521
Latest result4 demerits
Last inspectedMay 28, 2026
Inspections on record7
On record sinceJun 8, 2021

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 Jun 8, 2021: 10Jun 23, 2021: 0May 20, 2022: 10May 18, 2023: 4Apr 23, 2024: 12May 1, 2025: 8May 28, 2026: 4
Jun 8, 2021Lower is betterMay 28, 2026

Inspections & violations

May 28, 2026 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. - Observed flow meter not operating. Repaired during the inspection.

View this inspection on the county portal ›

May 1, 2025 8 demerits · 2 violations
Inspector comments: Inspection conducted with Chris Baker, CPO present PDSC information verified. No permit restrictions. Not permitted for night swimming. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed three missing wiers on the front side, right side, and back side of pool. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Observed back side and right rear corner of pool gate that was greater than 2 “ under fence.

View this inspection on the county portal ›

Apr 23, 2024 12 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Some debris on pool floor and floating debris. Vacuum out pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. 3 of 6 skimmers are missing weirs. Replace missing weirs.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter is not functioning. Replace flow meter.

View this inspection on the county portal ›

May 18, 2023 4 demerits · 1 violation
Inspector comments: Inspection conducted with CPO, Christopher Baker. PDSC information verified. 3 of 6 skimmers missing their weirs. CPO has placed order for 3x additional weirs. Night swimming not permitted. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 3 of 6 missing weirs. -4-

View this inspection on the county portal ›

May 20, 2022 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH recorded a 7.1 , CDI- CPO added soda ash and pH rose to 7.2
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was not operational. CDI- Fixed

View this inspection on the county portal ›

Jun 23, 2021 0 demerits · 0 violations
Inspector comments: Inspection completed with Ivan Gravely present. No signature due to COVID-19. Permanent signage present for emergency phone.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 8, 2021 10 demerits · 3 violations
Inspector comments: Onsite visit to pool for permit inspection and construction final. TCO on electrical panel given by Code Enforcement. Electrical permit is on order but has a 12 to 16 week lead time. Permit will not be issued for 2022 operating season unless permit has been finaled by Code Enforcement. E3439667 and E3439670. Permit issued for no night swimming. A seasonal sticker will be mailed to the facility. Hold released in system. Note: Verified pool hanging lights as plastic during the inspection. Note: Pool has not yet switched to salt. Handrails must be marine grade if using salt. Per contractor, marine grade handrails are on order. Note: Mulch added to fix barrier with >2" underneath. If washes out, may require permanent repair. Chiller to be installed at a later time. Chiller shall be submitted for approval to Code Enforcement prior to installation. Environmental Health requires approval. Chiller was disconnected - lines capped. Chiller to remain disconnected until approved by the Health Department. Pool has salt cell installed. Chiller manufacturer instructions state that operator must hose down with fresh water regularly on the fan motor shaft and fan motor housing as well as the sprinkler head assembly located through the fan guard. Failure to do so will cause salt residue buildup and will freeze up these parts and cause damage. Permanent Signage not provided for location of emergency phone. Given one week for correction. Signage must clearly identify location of emergency phone. Coolhand and David Bolt present for the inspection. Permit Restriction 1. Pool is not approved for salt as primary chlorination. Filtration Pump – Hayward SP3220EE, 2 hp pump with (2) Aquastar 12MFxxx drain covers. EQ lines plugged in skimmers. Feature Pump – Hayward SP3220EE, 2 hp pump with (2) Aquastar 12MFxxx drain covers. Max Depth – 4 ½ ft. Pool Width – 28 ft. Rope Length – 42 ft.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. Provided copy of log book to operator. Operator had not yet taken over the swimming pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
<45" from bottom horizontal to next horizontal at step up fence at right gate. Corrected during the inspection. >2" under post at gate at right gate entry. Corrected during the inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink stopper stuck in women's. Corrected during the inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GRIFF, THE” or State ID 2060501521). Inspection type (routine vs. follow-up) is not published in the county's data.