01632 May 28, 2021: 14Jun 3, 2021: 12Jun 22, 2022: 12Jul 5, 2023: 12Jun 5, 2024: 32Jun 7, 2024: 14May 14, 2025: 10May 23, 2025: 6
May 28, 2021Lower is betterMay 23, 2025

Inspections & violations

May 23, 2025 6 demerits · 1 violation
Inspector comments: Pool corrected the previous issue that caused the pool to fail. Observed correct signage. Pool now has “Adults should not swim alone” and Children should not use the swimming pool without adult supervision” in 1” height. Pool is open for 2025 season. No night swimming permit
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. phone number not posted at emergency phone. Pool operator posted the correct phone number.

View this inspection on the county portal ›

May 14, 2025 10 demerits · 2 violations
Inspector comments: Pool failed inspection due to not having proper signage. No “Adults should not swim alone” sign in 1” Minimum posted. No “Children should not use the swimming pool without adult supervision” sign in 1” minimum posted. 2024 Pool inspection also noted this violation. “Temporary” warning signs were posted in 2024. With the requirement to get a new warning sig within 1 week of the inspection. The phone number on the emergency phone did not match what 911 had on there records. Operator will need to correct this prior to new inspection. Prior to another inspection $100 fee will need to be paid to our front office. Please call 980-314-1680. Once the fee is paid a new inspection can be scheduled. Please call inspector Braedon Shelton to reschedule an inspection once the warning signage has been corrected and the phone number has been corrected on the emergency phone.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.

View this inspection on the county portal ›

Jun 7, 2024 14 demerits · 3 violations
Inspector comments: ** Brick cap on retaining wall damaged. Recommend repairing to prevent possible injury**
#5 · Water quality: daily written records of water quality and test kit kept on site −4
REAGENTS IN TEST KIT EXPIRED -- REPLACE WITHIN ONE WEEK
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
RING BUOY WITH BECKETS LOOSE -- READJUSTED DURING INSPECTION -- REPLACE/REPAIR WITHIN ONE WEEK
#18 · Premises: lifeguards present or warning signs posted −4
MISSING "CHILDREN" AND "ADULTS" SIGNS -- TEMPS POSTED -- OBTAIN PERMANENT SIGNS WITHIN ONE WEEK

View this inspection on the county portal ›

Jun 5, 2024 32 demerits · 8 violations
Inspector comments: REPAIR ITEMS PRIOR TO OPENING -- CALL WHEN READY - TIM 980-314-1620.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
MAINTAIN DAILY RECORDS --Cl, Ph, DRAIN CHECKS DAILY --CYANURIC ACID, TOTAL ALKILINITY WEEKLY
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
POOL DIRTY - CLEAN
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
SKIMMERS DIRTY - CLEAN
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
NO RING BUOY/ROPE - SUPPLY
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
GATE AT PARKING LOT NOT SELF-LATCHING -- REPAIR
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
MAINTAIN 6 FT CLEARANCE AROUND POOL
#19 · Premises: signs prohibit glass containers or pets in pool area −4
POST REQUIRED SIGNAGE
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
PUMP ROOM FLOOR WET; DOOR NOT LOCKED

View this inspection on the county portal ›

Jul 5, 2023 12 demerits · 2 violations
Inspector comments: Missing one page of records, ensure records are kept in order Several pool signs do not meet minimum 1” font for child swimming/adult swim alone. One sign is visible upon entry and meets requirements.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope tangled. Untangled and met length requirements
#22 · Premises: emergency telephone provided −6
Return phone number faded, though still legible. Operator re-printed during.

View this inspection on the county portal ›

Jun 22, 2022 12 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope 2 ft less than what is needed. CDI: rope length fixed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed gate latch nearest the pump and chemical room, less than 3 inches below from the top of the gate.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed chemical spilled onto the floor. CDI: chemical swept and cleaned out.

View this inspection on the county portal ›

Jun 3, 2021 12 demerits · 4 violations
Inspector comments: ITS for gates and fencing (no gaps greater than 1/2" within 18" of latching mechanism and maintain 2" or less from ground to fence). Recommended more permanent fix than pine straw, use material that will not wash away with drainage. General Comment: Emergency operator from 911 connected and called back to pool for a call that was not made. Ensure phone is working properly and not making calls out when not in use. Issued local permit sticker. No Night Swimming (added 'Dusk' as closing time to signage) Changed to "W" Intent to Suspend status. Inspection with Joshua Jett No signature due to COVID Pool not heated.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing daily main drain checks, weekly total alkalinity and cyanuric acid at time of visit, pool has only been opened since last week. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator took readings, checked main drains and recorded. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Meshing on fence greater than 1/2"x1/2" within 18" of push bar latching mechanism. Repair meshing to 1/2"x1/2" or eliminate openings >1/2" within 18" of push bar on all gates/fencing. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Gaps under fencing in back by grill area and near drainage with pebble rock greater than 2" from ground. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). *30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bags of chemicals/salt/cement stored on floor at time of inspection. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in men's restroom at time of inspection. Provide hand drying for hand washing. Operator placed towels in restroom and corrected.

View this inspection on the county portal ›

May 28, 2021 14 demerits · 3 violations
Inspector comments: Onsite visit to pool with Brock Melton for return construction. All items from construction corrected except items noted in inspection. Corrected during the site visit. Construction final passed. Joshua Jett present for operating permit. Operating permit issued for no night swimming. A follow-up inspection will be made by the Health Department within 2 weeks. Temporary meshing added to barrier in two locations. If replaced, must meet code requirements. Permit Restriction 1) Polymeric sand on pavers must remain in good repair. Item to Correct prior to follow-up visit. 1) Meshing on gate/barrier >1/2"x1/2". Repair meshing to 1/2"x1/2" or eliminate openings >1/2" within 18" of push bar on all gates/fencing Note – (2) drains in middle are for Filtration drains. (2) outside drains are for feature pump. Filtration – Pentair Whisperflo WFE-6, 1.5 hp pump with (2) Aquastar 914xxx drain covers. EQ lines plugged in skimmer. Feature – Pentair Whisperflo WFE-3, ¾ hp pump with (2) Aquastar 914xxx drain covers. Pool Width – 31 ft. Rope Length – 46 ft. Max Depth 5 ft..
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Log book not maintained. Pool was not open to the public at time of inspection. Ensure daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for total alkalinity and cyanuric acid. Log book onsite during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Meshing on gate/barrier >1/2"x1/2". Repair meshing to 1/2"x1/2" or eliminate openings >1/2" within 18" of push bar on all gates/fencing prior to follow-up inspection. >4" between post and picket near emergency phone. Corrected with meshing to eliminate opening. <45" between Duke box and horizontal on barrier and at tie into main building from electrical to horizontal. Meshing added to eliminate horizontal to maintain 45". >1/2" between post and gate on all three gates. Metal added during inspection.
#22 · Premises: emergency telephone provided −6
Phone number not posted at emergency phone. Corrected during the inspection. Recommend providing permanent signage. Written in with sharpie.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “AVION POINT” or State ID 2060501525). Inspection type (routine vs. follow-up) is not published in the county's data.