4demerits
MADISON, THE - LOWER POOL
7815 CALIBRE CROSSING DR, Charlotte, NC 28227
Seasonal Swimming Pool · NC permit/State ID 2060501540
Latest result4 demerits
Last inspectedApr 17, 2026
Inspections on record5
On record sinceMay 25, 2022
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 25, 2022Lower is betterApr 17, 2026
Inspections & violations
Apr 17, 2026 4 demerits · 1 violation
Inspector comments: All violations corrected at time of inspection. Inspection conducted with CPO - Martin Martinez.
Permit restrictions: Flow meter must remain operable. Flow required to be below 119gpm due to drain Cover Flow restriction. Suction hazard.
Note: Skimmer line not tied to waterfall pump (waterfall pump has been removed).
Pool permit issued. Pool is okay to open at owner’s discretion. Permit sticker issued.
Night swimming is not permitted.`
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Observed pool logs that do not include cyanuric acid and total alkalinity levels recorded. CDI - CPO recorded results for levels taken this morning and will record weekly notations going forward.
Jul 31, 2025 16 demerits · 3 violations
Inspector comments: Permit suspended for pH.
Contact Chris Sells when repairs are completed at 704 576 8678.
Permit Restriction: Flow meter must remain operable. Flow required below 119 gpm due to drain cover
flow restriction. Suction Hazard.
#3 · Water quality: pool water pH −6
Observed pH below 7.2.
.2535(1) Maintain pH at 7.2 to 7.8.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy becket rope damaged. Replaced during inspection.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Body hook on telescopic pole, corrected during inspection.
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gates not meeting requirements throughout, less than 42" between horizontals and 3" from gate and grade.
Gates must have at least 45" between horizontal member, and must have no more than 2" between bottom of gate and grade.
Jun 11, 2025 20 demerits · 5 violations
Inspector comments: Pool closes at dusk
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed pool logs that does not include section to record checks for cyanuic acid levels. CDI provided county pool log sheet to use.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cracks in the deck that were less than a 1/2”. Observed drain grates on pool deck that are cracking and in need of replacement.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone with sign with an inaccurate number. CDI wrote proper number on kings III unit and ordered new sign.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping in pump room not labeled.
May 19, 2023 8 demerits · 3 violations
Inspector comments: Note: no signature as I had to return to office to type up.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. Observed service gate opens towards pool. Per Tim Dutcher, service gate must be corrected to open away from the pool before 2024 permit can be issued
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed pipes missing labeling of flow. Label both pool and waterfall piping
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed restroom and fixtures soiled.
May 25, 2022 14 demerits · 4 violations
Inspector comments: Night swimming not permitted.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope length measuring 29 ft. 7 in. CDI, rope corrected to required length.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture 4 ft. 5 in. From edge of pool deck.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed pipes missing labeling of flow.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed restroom and fixtures soiled.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MADISON, THE - LOWER POOL” or State ID 2060501540). Inspection type (routine vs. follow-up) is not published in the county's data.