‹ Back to search

14demerits

ACCENT SOUTHRAIL APARTMENTS

6026 STATION CROSSING AVE, Charlotte, NC 28217
Seasonal Swimming Pool · NC permit/State ID 2060501567
Latest result14 demerits
Last inspectedApr 8, 2026
Inspections on record6
On record sinceJul 1, 2022

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 Jul 1, 2022: 6Aug 25, 2022: 16Apr 20, 2023: 4May 23, 2024: 8May 9, 2025: 12Apr 8, 2026: 14
Jul 1, 2022Lower is betterApr 8, 2026

Inspections & violations

Apr 8, 2026 14 demerits · 3 violations
Inspector comments: Inspection conducted with CPO, James Jackson. Permit restriction: Pump must remain at 3450 RPM due to design specifications of system and turnover Note: Pool not approved for salt as primary chlorination. -Auto chlorination interlock tested and operational. -Night swimming NOT allowed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. Observed 6 equalizers in skimmer baskets without plugs. According to PDSC form, establishment should have equalizers lines disabled and plugged. EHS will follow up with CPO and ensure correction in coming week. CPO encouraged to reach out with any questions, or once completed. CPO advised to ensure water is cleared from lines before plugging.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed deteriorated rope snap from ring buoy with mild tension applied. Corrected- CPO replaces with new rope, 50 feet in length, during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed one push-bar latch mechanism gate onto pool deck self latch, but not self close. Corrected- CPO tightens hinges and gate self closes, self locks.

View this inspection on the county portal ›

May 9, 2025 12 demerits · 2 violations
Inspector comments: Inspection completed with CPO, James Jackson All permit compliance items corrected during inspection Interlock tested and operational CPO log records begin today NO NIGHT SWIMMING ALLOWED Pump must remain at 3450 RPM due to design specifications of system and turnover. Pool not approved for salt as primary chlorination. Feature pump has Hayward HSP3210EE listed as the pump. Pump tag reads Hayward SP3210EE. Both pump curves have a maximum of 131gpm. Permit issued
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed a loose screw and body hook. CDI - CPO tightened screws during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed a worn address label and phone number. CDI - CPO darkened signage with a sharpie during inspection.

View this inspection on the county portal ›

May 23, 2024 8 demerits · 2 violations
Inspector comments: NIGHT SWMIMMING NOT PERMITTED. PUMP MUST REMAIN AT 3450 RPM. SALT NOT APPROVED AS PRIMARY CHOLRINATOR.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. No signage showing phone number and address at pool phone CDI - Provided.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. No arrows on pipe. CDI - Provided.

View this inspection on the county portal ›

Apr 20, 2023 4 demerits · 1 violation
Inspector comments: Pool inspection conducted with CPO Danny. The 2 gates that did not self-latch was fixed during inspection and are now latching on.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 2 gates leading into the pool did not self latch.

View this inspection on the county portal ›

Aug 25, 2022 16 demerits · 3 violations
Inspector comments: Call Chris Sells when repairs are complete to reopen pool at 704 576 8678
#2 · Water quality: disinfectant residual provided by −6
CL must be at 1ppm
#3 · Water quality: pool water pH −6
pH must be between 7.2 or 7.8 Immediate suspension items
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
observed fence picket damaged to the left of the gate on entry at artificial turf

View this inspection on the county portal ›

Jul 1, 2022 6 demerits · 2 violations
Inspector comments: Onsite visit to pool for return construction. Construction final passed. Permit issued for no night swimming while onsite. Holds released in system. Note: Area located to right of main entry gate appears to be corrected with drainage. If issue in the future with holding water or build-up, may require repair in future inspections. Continue to monitor and address if needed. Permit Restrictions: 1) Pump must remain at 3450 RPM due to design specifications of system and turnover. 2) Pool not approved for salt as primary chlorination. Pool needs 13 lbs per day for salt. System only produces 10 lbs/day. Filtration - Hayward SP3020VSP 2.7 THP with (1) Aquastar WAV12WRxxx VGBA-2008 and (1) Aquastar WAVWRxxx VGBA2017 drain cover. EQ lines plugged in skimmer. Feature - Hayward SP3210EE 1 hp pump with (2) Aquastar WAV9WRxxx VGBA2008 drain covers. Max Depth - 4 1/2 ft. Pool Width - 43 ft. Rope Length - 50 ft. No signature. Mobile CDP not operating on laptop. Computer is at Dell for repair. Report emailed to GC (Sean McQuade), CPO (Danny Grier) and pool contractor (Aquatica Pools). An unannounced follow-up inspection will be completed by our Department within 30 days of permit issuance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor in pump room wet. Equipment verified as not leaking. Mop sink on opposite side of wall. Bucket was spilled and leaked through side wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates with >1/2" within 18" of latch mechanism. Corrected during the inspection. Gate near emergency phone not self-closing, self-latching. Repaired during the inspection. >2" under back gate. Corrected during the inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ACCENT SOUTHRAIL APARTMENTS” or State ID 2060501567). Inspection type (routine vs. follow-up) is not published in the county's data.