‹ Back to search

4demerits

ANDOVER WOODS II LOWER

7808 ANDOVER WOODS DR, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060501568
Latest result4 demerits
Last inspectedJun 11, 2026
Inspections on record5
On record sinceJul 2, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01632 Jul 2, 2024: 32Aug 1, 2024: 10Jul 2, 2025: 24Jul 16, 2025: 8Jun 11, 2026: 4
Jul 2, 2024Lower is betterJun 11, 2026

Inspections & violations

Jun 11, 2026 4 demerits · 1 violation
Inspector comments: No permit conditions Pool not approved for night swimming
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter observed to be non operational. Operator contacted pool technician who arrived during inspection to install new flow meter which was operational.

View this inspection on the county portal ›

Jul 16, 2025 8 demerits · 2 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed 1 3ft depth marker starting to fade. Fill in or repaint.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cracking on decks throughout. Does not present hazard at time of inspection.

View this inspection on the county portal ›

Jul 2, 2025 24 demerits · 5 violations
Inspector comments: Make corrections. Call EH front desk to pay re-inspection fee: 980-314-1620 Contact inspector to reschedule.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed 1 3ft depth marker starting to fade. Fill in or repaint.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy greater than 30’. -CDI- CPO corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cracking on decks throughout. Does not present hazard at time of inspection.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed lettering less than 4”. -CDI- CPO presented another sign.

View this inspection on the county portal ›

Aug 1, 2024 10 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Fencing on far side of pool in three different areas have spaces ranging from 6 to 12 inches between bottom horizontal of fence and ground.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. A sign was not posted listing address of pool and emergency phone number. Management posted a sign with address of pool and emergency phone number during inspection.

View this inspection on the county portal ›

Jul 2, 2024 32 demerits · 7 violations
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Chlorinator not operational.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weirs in both skimmers.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Observed depth markers spaced greater than 25 feet measured along the perimeter of the pool. Depth markers spray painted on pool deck by CPO during inspection. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. Observed no diving markers spaced greater than 25 feet as the crow flies. No diving markers spray painted on pool deck by CPO during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Fencing on far side of pool in three different areas have spaces ranging from 6 to 12 inches between bottom horizontal of fence and ground.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Pool has signs posted “no lifeguard on duty” in less than 4 inch lettering. Management posted a sign “Warning - No Lifeguard on Duty” in 4 inch lettering during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. A sign was not posted listing address of pool and emergency phone number. Management posted a sign with address of pool and emergency phone number during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter inoperable.

View this inspection on the county portal ›