6demerits
ANDOVER WOODS I UPPER
7808 ANDOVER WOODS DR, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060501569
Latest result6 demerits
Last inspectedJun 11, 2026
Inspections on record6
On record sinceJul 2, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 2, 2024Lower is betterJun 11, 2026
Inspections & violations
Jun 11, 2026 6 demerits · 2 violations
Inspector comments: No permit conditions
Pool not approved for night swimming
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladder is missing pool ladder end caps. Install end caps.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter observed to be non operational. Operator contacted pool technician who arrived during inspection to install new flow meter which was operational
Jul 16, 2025 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed minor cracking on decks throughout. Does not present hazard at time of inspection.
Jul 9, 2025 16 demerits · 3 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine less than 1.0ppm.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.9.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed minor cracking on decks throughout. Does not present hazard at time of inspection.
Jul 2, 2025 18 demerits · 4 violations
Inspector comments: Make corrections.
Call EH front desk to pay re-inspection fee: 980-314-1620
Contact inspector to reschedule.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed minor cracking on decks throughout. Does not present hazard at time of inspection.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed signage with lettering less than 4”. -CDI- CPO provided appropriate signage.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed damaged spare pump basket.
Aug 1, 2024 14 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed weir in skimmer on far side not attached to anything in skimmer. Secure weir to ensure it is operating properly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Fencing on far side of pool in three different areas have spaces ranging from 6 to 12 inches between bottom horizontal of fence and ground.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. A sign was not posted listing address of pool and emergency phone number. Management posted a sign with address of pool and emergency phone number during inspection.
Jul 2, 2024 22 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weirs in both skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Fencing on far side of pool in three different areas have spaces ranging from 6 to 12 inches between bottom horizontal of fence and ground.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Pool has signs posted “no lifeguard on duty” in less than 4 inch lettering. Management posted a sign “Warning - No Lifeguard on Duty” in 4 inch lettering during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. A sign was not posted listing address of pool and emergency phone number. Management posted a sign with address of pool and emergency phone number during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was not operational.