‹ Back to search

10demerits

SPIRE LUXURY APARTMENTS

3021 SPIRE VIEW LN, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060501611
Latest result10 demerits
Last inspectedMay 29, 2026
Inspections on record3
On record sinceJul 2, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Jul 2, 2024: 0Apr 23, 2025: 0May 29, 2026: 10
Jul 2, 2024Lower is betterMay 29, 2026

Inspections & violations

May 29, 2026 10 demerits · 2 violations
Inspector comments: 5% flow meter was installed and field verified by EHS during time of inspection. PERMIT RESTRICTION: Pump required at 3450 RPM. Filtration flow meter must remain operable. Flow shall be maintained at 144gpm to 180 gpm to meet turnover and flow restriction of the number of returns. Flow greater than 275 gpm exceeds main drains. Suction hazard. NIGHT SWIMMING NOT PERMITTED
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed low chlorine at start of inspection. Corrected to 1.0 ppm by conclusion of inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing and self-latching. Observed one pool door not self-latching (door located furthest from the pool house and closest to the leasing office). Door was adjusted during inspection and became self-latching.

View this inspection on the county portal ›

Apr 23, 2025 0 demerits · 0 violations
Inspector comments: No violations observed during inspection No night swimming Pumps and Drain covers verified during inspection as same on PDSC form Permit restriction: Flow cannot exceed 275 gpm for drain cover limitation. Pump must be set at maximum speed or maintain a minimum flow rate of 144 gpm for turnover and a maximum speed of 180 gpm limited by number of returns. Flow meter was functioning and flow reading was 150 gpm.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 2, 2024 0 demerits · 0 violations
Inspector comments: Observed no non-compliant conditions. Night swimming Notes: Pump approved on design flow at max speed 3450rpm; Pump must be set at max speed or maintain a minimum flow rate of 144gpm for turnover and a maximum speed of 180gpm limited by number of returns and a properly installed and operating flow meter at all times.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SPIRE LUXURY APARTMENTS” or State ID 2060501611). Inspection type (routine vs. follow-up) is not published in the county's data.