COULWOOD SWIM CLUB
409 COULWOOD DR, Charlotte, NC 28214
Seasonal Swimming Pool · NC permit/State ID 2060501613
Latest result4 demerits
Last inspectedApr 21, 2026
Inspections on record4
On record sinceJun 28, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 28, 2024Lower is betterApr 21, 2026
Inspections & violations
Apr 21, 2026 4 demerits · 1 violation
Inspector comments: Night swimming approved.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.
Observed flow meter not working correctly. Corrected During Inspection - CPO turned off the pump and was able to get the flow meter to work correctly. No permit action necessary.
Apr 9, 2025 4 demerits · 1 violation
Inspector comments: Possibly return tonight for Night Swimming approval no confirmation yet on HOA.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris/insects throughout pool floors and near main drain covers.
Jul 10, 2024 12 demerits · 3 violations
Inspector comments: Return visit to be completed to ensure turnover is maintained.
Permit Restriction: Flow meter must remain operational. Flow must be at least 463 gpm and cannot exceed 588 gpm.
#2 · Water quality: disinfectant residual provided by −6
Observed CL level at .6ppm, raised to 1.0 ppm during inspection.
.2535(4) Maintain chlorine at least 1.0 ppm.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump flow unable to meet minimum turnover required for permit condition.
.2518(h) Provide approved pump in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room area unlocked.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Jun 28, 2024 0 demerits · 0 violations
Inspector comments: Scope of Work Pool raised to 5 ft. max depth. New equipment in pump room. Floor/floor drain existing and building existing (outside). New chemical storage room. Restroom shells are existing along with main building. New fixtures replaced in restrooms. Plumbing run for future slide. Slide not installed. Pump for slide not installed.
All items corrected from previous visit. Verified with pictures provided by Jeff Gaeckle. Construction final passed. Permit issued for no night swimming. Holds released in system.
Permit Restrictions:
1) VFD for filtration pump shall remain operable. Flow meter shall remain operable. Flow shall be kept at 463 gpm to 588 gpm to meet turnover and flow restriction of filters.
2) Aerator not approved for use while pool is open to public.
3) Left side door on double door entry into building must remain locked so that doors self-close, self-latch.
Note: Equipment room floor and floor drain existing. Restroom floor and floor drain existing.
Note: Maintenance gate at equipment room permitted with handle at 40” from ground due to building code.
Filtration - Pentair EQ1500, 15 hp pump with (12) VGBA-2017 Aquastar 18MFxxxxxx drain covers. EQ lines plugged in skimmer.
Aerator Hayward HCP20303 with (2) VGBA-2017 Aquastar 12MFxxx drain covers.
Slide No pump installed for slide at time of inspection. Future install approved with Hayward HCP20073. Slide and aerator pull through same suction line through 12x12 drain covers.
CMD Nova drain cover on hydrostat no suction.
Report emailed to Jeff Gaeckle.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “COULWOOD SWIM CLUB” or State ID 2060501613). Inspection type (routine vs. follow-up) is not published in the county's data.